These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 28517390)

  • 1. SU-D-BRA-02: An Extended Time-Variant Seasonal Autoregressive Model-Based Prediction for Irregular Breathing Motion Tracking.
    Ichiji K; Homma N; Sakai M; Narita Y; Takai Y; Yoshizawa M
    Med Phys; 2012 Jun; 39(6Part3):3616. PubMed ID: 28517390
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Respiratory motion prediction for tumor following radiotherapy by using time-variant seasonal autoregressive techniques.
    Ichiji K; Homma N; Sakai M; Takai Y; Narita Y; Abe M; Sugita N; Yoshizawa M
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():6028-31. PubMed ID: 23367303
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adaptive prediction of respiratory motion for motion compensation radiotherapy.
    Ren Q; Nishioka S; Shirato H; Berbeco RI
    Phys Med Biol; 2007 Nov; 52(22):6651-61. PubMed ID: 17975289
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A time-varying seasonal autoregressive model-based prediction of respiratory motion for tumor following radiotherapy.
    Ichiji K; Homma N; Sakai M; Narita Y; Takai Y; Zhang X; Abe M; Sugita N; Yoshizawa M
    Comput Math Methods Med; 2013; 2013():390325. PubMed ID: 23840277
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technical aspects of real time positron emission tracking for gated radiotherapy.
    Chamberland M; McEwen MR; Xu T
    Med Phys; 2016 Feb; 43(2):783-95. PubMed ID: 26843241
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-time tumor tracking with preprogrammed dynamic multileaf-collimator motion and adaptive dose-rate regulation.
    Yi BY; Han-Oh S; Lerma F; Berman BL; Yu C
    Med Phys; 2008 Sep; 35(9):3955-62. PubMed ID: 18841846
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Predicting respiratory motion for four-dimensional radiotherapy.
    Vedam SS; Keall PJ; Docef A; Todor DA; Kini VR; Mohan R
    Med Phys; 2004 Aug; 31(8):2274-83. PubMed ID: 15377094
    [TBL] [Abstract][Full Text] [Related]  

  • 8. GateCT™ surface tracking system for respiratory signal reconstruction in 4DCT imaging.
    Kauweloa KI; Ruan D; Park JC; Sandhu A; Kim GY; Pawlicki T; Watkins WT; Song B; Song WY
    Med Phys; 2012 Jan; 39(1):492-502. PubMed ID: 22225320
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SU-E-J-146: Time Series Prediction of Lung Cancer Patients' Breathing Pattern Based on Nonlinear Dynamics.
    Tolakanahalli R; Tewatia D; Tome W
    Med Phys; 2012 Jun; 39(6Part8):3686. PubMed ID: 28518937
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Prediction of respiratory motion based on nonparametric regression for real-time tumor-tracking radiotherapy].
    Ouyang B; Lu WT; Dou JH; Zhou LH
    Nan Fang Yi Ke Da Xue Xue Bao; 2011 Oct; 31(10):1682-6. PubMed ID: 22027767
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Using an external surrogate for predictor model training in real-time motion management of lung tumors.
    Rottmann J; Berbeco R
    Med Phys; 2014 Dec; 41(12):121706. PubMed ID: 25471953
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time prediction of respiratory motion based on a local dynamic model in an augmented space.
    Hong SM; Jung BH; Ruan D
    Phys Med Biol; 2011 Mar; 56(6):1775-89. PubMed ID: 21346273
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dual-component model of respiratory motion based on the periodic autoregressive moving average (periodic ARMA) method.
    McCall KC; Jeraj R
    Phys Med Biol; 2007 Jun; 52(12):3455-66. PubMed ID: 17664554
    [TBL] [Abstract][Full Text] [Related]  

  • 14. WE-G-213CD-09: Quality Assurance of the Surrogate Signal-Based Dynamic Tumor-Tracking Irradiation with Vero4DRT (MHI-TM2000).
    Mukumoto N; Nakamura M; Sawada A; Suzuki Y; Takahashi K; Miyabe Y; Kaneko S; Mizowaki T; Kokubo M; Hiraoka M
    Med Phys; 2012 Jun; 39(6Part28):3972. PubMed ID: 28519631
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files.
    Hoogeman M; Prévost JB; Nuyttens J; Pöll J; Levendag P; Heijmen B
    Int J Radiat Oncol Biol Phys; 2009 May; 74(1):297-303. PubMed ID: 19362249
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery.
    Vedam S; Docef A; Fix M; Murphy M; Keall P
    Med Phys; 2005 Jun; 32(6):1607-20. PubMed ID: 16013720
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy.
    Li R; Lewis JH; Jia X; Gu X; Folkerts M; Men C; Song WY; Jiang SB
    Med Phys; 2011 May; 38(5):2783-94. PubMed ID: 21776815
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Smoothing of respiratory motion traces for motion-compensated radiotherapy.
    Ernst F; Schlaefer A; Schweikard A
    Med Phys; 2010 Jan; 37(1):282-94. PubMed ID: 20175491
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance evaluation of real-time motion tracking using positron emission fiducial markers.
    Chamberland M; Wassenaar R; Spencer B; Xu T
    Med Phys; 2011 Feb; 38(2):810-9. PubMed ID: 21452718
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Toward submillimeter accuracy in the management of intrafraction motion: the integration of real-time internal position monitoring and multileaf collimator target tracking.
    Sawant A; Smith RL; Venkat RB; Santanam L; Cho B; Poulsen P; Cattell H; Newell LJ; Parikh P; Keall PJ
    Int J Radiat Oncol Biol Phys; 2009 Jun; 74(2):575-82. PubMed ID: 19327907
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.