These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 28517814)

  • 1. SU-E-T-202: Comprehensive Quality Assurance Procedures for Uniform Scanning Proton Therapy Machines.
    Zheng Y; Ding X; Mascia A; Hsi W; Kang Y; Ramirez E; Zeidan O; Schreuder N
    Med Phys; 2012 Jun; 39(6Part12):3749. PubMed ID: 28517814
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SU-E-T-301: A Novel Daily QA Device for Proton Therapy.
    Ding X; Zheng Y; Mascia A; Hsi W; Kang Y; Ramirez E; Zeidan O; Foster R; Gao M; Laub S; Pankuch M; Schreuder N; Harris B
    Med Phys; 2012 Jun; 39(6Part14):3772-3773. PubMed ID: 28517302
    [TBL] [Abstract][Full Text] [Related]  

  • 3. MO-D-BRCD-01: Overview of Clinical Dosimetry and Quality Assurance in Proton Therapy.
    Zeidan O; Zheng Y
    Med Phys; 2012 Jun; 39(6Part21):3865. PubMed ID: 28518259
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of machine-specific tolerances using statistical process control analysis of long-term uniform scanning proton machine QA results.
    Rana S; Eckert C; Singh H; Zheng Y; Chacko M; Storey M; Chang J
    J Appl Clin Med Phys; 2020 Sep; 21(9):163-170. PubMed ID: 32741135
    [TBL] [Abstract][Full Text] [Related]  

  • 5. SU-E-T-127: Feasibility Study for Using a 2D Array Detector for All Beam Measurements in Monthly Quality Assurance Procedure for a Uniform Scanning Proton Therapy System.
    Rains M; Mascia A; Ramirez E; Zheng Y; Ding X; Neuenschwander D; Harris B
    Med Phys; 2012 Jun; 39(6Part11):3732. PubMed ID: 28517158
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Technical Note: An efficient daily QA procedure for proton pencil beam scanning.
    Younkin JE; Shen J; Bues M; Robertson DG; Mundy DW; Clouser E; Liu W; Ding X; Stoker JB
    Med Phys; 2018 Mar; 45(3):1040-1049. PubMed ID: 29394447
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical Note: A simple and fast daily quality assurance solution for modulated scanning proton and carbon ion beams.
    Chen JN; Moyers MF; Lin LC
    Med Phys; 2021 Oct; 48(10):5684-5693. PubMed ID: 34370305
    [TBL] [Abstract][Full Text] [Related]  

  • 8. AAPM task group 224: Comprehensive proton therapy machine quality assurance.
    Arjomandy B; Taylor P; Ainsley C; Safai S; Sahoo N; Pankuch M; Farr JB; Yong Park S; Klein E; Flanz J; Yorke ED; Followill D; Kase Y
    Med Phys; 2019 Aug; 46(8):e678-e705. PubMed ID: 31125441
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SU-D-BRCD-01: Evaluation of Zebra Multi-Layer Ionization Chamber System for Patient Treatment Field and Machine QA for Spot Scanning and Passive Scattering Proton Beams.
    Dhanesar S; Sahoo N; Taylor M; Song X; Poenisch F; Summers P; Li H; Zhu XR; Gillin M
    Med Phys; 2012 Jun; 39(6Part3):3613. PubMed ID: 28517385
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility study of utilizing Sphinx Compact for quality assurance in uniform scanning proton therapy.
    Rana S; Eckert C; Tesfamicael B
    Phys Med; 2023 Sep; 113():102468. PubMed ID: 36336530
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance.
    Arjomandy B; Sahoo N; Ding X; Gillin M
    Med Phys; 2008 Sep; 35(9):3889-94. PubMed ID: 18841839
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quality assurance of scanned proton beams at different gantry angles using an ionization chamber array in a rotational phantom.
    Decabooter E; Roijen E; Martens J; Unipan M; Bosmans G; Vilches-Freixas G
    Phys Med; 2022 Dec; 104():67-74. PubMed ID: 36370605
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factor 10 Expedience of Monthly Linac Quality Assurance via an Ion Chamber Array and Automation Scripts.
    Skinner LB; Yang Y; Hsu A; Xing L; Yu AS; Niedermayr T
    Technol Cancer Res Treat; 2019; 18():1533033819876897. PubMed ID: 31707931
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring Daily QA 3 constancy for routine quality assurance on linear accelerators.
    Binny D; Lancaster CM; Kairn T; Trapp JV; Crowe SB
    Phys Med; 2016 Nov; 32(11):1479-1487. PubMed ID: 27839928
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SU-E-T-238: Annual QA of Proton Gantry with Robotic Table.
    Wang N; Ghebremedhin A; Simpson R; Patyal B
    Med Phys; 2012 Jun; 39(6Part13):3758. PubMed ID: 28517322
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Daily QA in proton therapy using a single commercially available detector.
    Lambert J; Bäumer C; Koska B; Ding X
    J Appl Clin Med Phys; 2014 Nov; 15(6):5005. PubMed ID: 25493526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom.
    Bizzocchi N; Fracchiolla F; Schwarz M; Algranati C
    Med Dosim; 2017 Autumn; 42(3):238-246. PubMed ID: 28645509
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Daily Quality Assurance Efficiency Evaluation Using SunCHECK Machine and Machine Performance Check.
    Stambaugh C; Yancey J; Shukla U; Melhus C; Stambaugh N
    Cureus; 2023 Mar; 15(3):e35695. PubMed ID: 37012967
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel daily QA system for proton therapy.
    Ding X; Zheng Y; Zeidan O; Mascia A; Hsi W; Kang Y; Ramirez E; Schreuder N; Harris B
    J Appl Clin Med Phys; 2013 Mar; 14(2):4058. PubMed ID: 23470936
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of a QA method to characterize submillimeter-sized PBS beam properties using a 2D ionization chamber array.
    Lin Y; Bentefour H; Flanz J; Kooy H; Clasie B
    Phys Med Biol; 2018 May; 63(10):105007. PubMed ID: 29644984
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.