These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 28519816)

  • 41. The first clinical treatment with kilovoltage intrafraction monitoring (KIM): a real-time image guidance method.
    Keall PJ; Aun Ng J; O'Brien R; Colvill E; Huang CY; Rugaard Poulsen P; Fledelius W; Juneja P; Simpson E; Bell L; Alfieri F; Eade T; Kneebone A; Booth JT
    Med Phys; 2015 Jan; 42(1):354-8. PubMed ID: 25563275
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A modality conversion approach to MV-DRs and KV-DRRs registration using information bottlenecked conditional generative adversarial network.
    Liu C; Lu Z; Ma L; Wang L; Jin X; Si W
    Med Phys; 2019 Oct; 46(10):4575-4587. PubMed ID: 31420963
    [TBL] [Abstract][Full Text] [Related]  

  • 43. 2D/3D image fusion for accurate target localization and evaluation of a mask based stereotactic system in fractionated stereotactic radiotherapy of cranial lesions.
    Jin JY; Ryu S; Faber K; Mikkelsen T; Chen Q; Li S; Movsas B
    Med Phys; 2006 Dec; 33(12):4557-66. PubMed ID: 17278807
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Image-guided radiotherapy in near real time with intensity-modulated radiotherapy megavoltage treatment beam imaging.
    Mao W; Hsu A; Riaz N; Lee L; Wiersma R; Luxton G; King C; Xing L; Solberg T
    Int J Radiat Oncol Biol Phys; 2009 Oct; 75(2):603-10. PubMed ID: 19735886
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy.
    Hawkins MA; Brock KK; Eccles C; Moseley D; Jaffray D; Dawson LA
    Int J Radiat Oncol Biol Phys; 2006 Oct; 66(2):610-9. PubMed ID: 16966004
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Characterization of a real-time surface image-guided stereotactic positioning system.
    Peng JL; Kahler D; Li JG; Samant S; Yan G; Amdur R; Liu C
    Med Phys; 2010 Oct; 37(10):5421-33. PubMed ID: 21089778
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Registration of DRRs and portal images for verification of stereotactic body radiotherapy: a feasibility study in lung cancer treatment.
    Künzler T; Grezdo J; Bogner J; Birkfellner W; Georg D
    Phys Med Biol; 2007 Apr; 52(8):2157-70. PubMed ID: 17404461
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Markerless real-time 3-D target region tracking by motion backprojection from projection images.
    Rohlfing T; Denzler J; Grässl C; Russakoff DB; Maurer CR
    IEEE Trans Med Imaging; 2005 Nov; 24(11):1455-68. PubMed ID: 16279082
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification.
    Yin FF; Guan H; Lu W
    Med Phys; 2005 Sep; 32(9):2819-26. PubMed ID: 16266096
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Automatic marker detection and 3D position reconstruction using cine EPID images for SBRT verification.
    Park SJ; Ionascu D; Hacker F; Mamon H; Berbeco R
    Med Phys; 2009 Oct; 36(10):4536-46. PubMed ID: 19928085
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Advances in 4D medical imaging and 4D radiation therapy.
    Li G; Citrin D; Camphausen K; Mueller B; Burman C; Mychalczak B; Miller RW; Song Y
    Technol Cancer Res Treat; 2008 Feb; 7(1):67-81. PubMed ID: 18198927
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Real-time automatic fiducial marker tracking in low contrast cine-MV images.
    Lin WY; Lin SF; Yang SC; Liou SC; Nath R; Liu W
    Med Phys; 2013 Jan; 40(1):011715. PubMed ID: 23298085
    [TBL] [Abstract][Full Text] [Related]  

  • 53. SU-E-J-20: Evaluation of Image Qualities and Registration of Varian KV-CBCT Images Reconstructed from the Reduced Number of Projections.
    Xu H
    Med Phys; 2012 Jun; 39(6Part6):3656. PubMed ID: 28517589
    [TBL] [Abstract][Full Text] [Related]  

  • 54. SU-E-J-33: Geometric Agreement Check for Imaging System with Radiation Beam by KV and MV-CBCT.
    Saotome N; Kida S; Haga A; Masutani Y; Ohtomo K; Nakagawa K
    Med Phys; 2012 Jun; 39(6Part6):3659. PubMed ID: 28517564
    [TBL] [Abstract][Full Text] [Related]  

  • 55. 3D PET image reconstruction including both motion correction and registration directly into an MR or stereotaxic spatial atlas.
    Gravel P; Verhaeghe J; Reader AJ
    Phys Med Biol; 2013 Jan; 58(1):105-26. PubMed ID: 23221063
    [TBL] [Abstract][Full Text] [Related]  

  • 56. SU-E-I-22: Metal Artifact Correction Using KV and Selective MV Imaging.
    Keil A; Zhu L; Star-Lack J; Fahrig R
    Med Phys; 2012 Jun; 39(6Part4):3629. PubMed ID: 28519536
    [TBL] [Abstract][Full Text] [Related]  

  • 57. A computerized framework for monitoring four-dimensional dose distributions during stereotactic body radiation therapy using a portal dose image-based 2D/3D registration approach.
    Nakamoto T; Arimura H; Nakamura K; Shioyama Y; Mizoguchi A; Hirose TA; Honda H; Umezu Y; Nakamura Y; Hirata H
    Comput Med Imaging Graph; 2015 Mar; 40():1-12. PubMed ID: 25592290
    [TBL] [Abstract][Full Text] [Related]  

  • 58. An optimization algorithm for 3D real-time lung tumor tracking during arc therapy using kV projection images.
    Zhuang L; Liang J; Yan D; Zhang T; Marina O; Ionascu D
    Med Phys; 2013 Oct; 40(10):101710. PubMed ID: 24089900
    [TBL] [Abstract][Full Text] [Related]  

  • 59. SU-E-J-126: Generation of Fluoroscopic 3D Images Using Single X-Ray Projections on Realistic Modified XCAT Phantom Data.
    Mishra P; Li R; St James S; Yue Y; Mak R; Berbeco R; Lewis J
    Med Phys; 2012 Jun; 39(6Part8):3681. PubMed ID: 28518907
    [TBL] [Abstract][Full Text] [Related]  

  • 60. 3D interfractional patient position verification using 2D-3D registration of orthogonal images.
    Jans HS; Syme AM; Rathee S; Fallone BG
    Med Phys; 2006 May; 33(5):1420-39. PubMed ID: 16752578
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.