These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 28522868)

  • 1. First demonstration of multi-color 3-D in vivo imaging using ultra-compact Compton camera.
    Kishimoto A; Kataoka J; Taya T; Tagawa L; Mochizuki S; Ohsuka S; Nagao Y; Kurita K; Yamaguchi M; Kawachi N; Matsunaga K; Ikeda H; Shimosegawa E; Hatazawa J
    Sci Rep; 2017 May; 7(1):2110. PubMed ID: 28522868
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A hybrid coded-aperture and Compton camera based on cerium-doped Gd
    Kong L; Shuai L; Liang X; Li D; Zhang J; Zhou W; Yang Y; Wang X; Hu X; Li C; Yu Y; Ding Y; Meng F; Zhang Y; Wei L
    Rev Sci Instrum; 2022 Nov; 93(11):113103. PubMed ID: 36461454
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance demonstration of a hybrid Compton camera with an active pinhole for wide-band X-ray and gamma-ray imaging.
    Omata A; Kataoka J; Fujieda K; Sato S; Kuriyama E; Kato H; Toyoshima A; Teramoto T; Ooe K; Liu Y; Matsunaga K; Kamiya T; Watabe T; Shimosegawa E; Hatazawa J
    Sci Rep; 2020 Aug; 10(1):14064. PubMed ID: 32820211
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of a high-resolution Si-PM-based gamma camera system.
    Yamamoto S; Watabe H; Kanai Y; Imaizumi M; Watabe T; Shimosegawa E; Hatazawa J
    Phys Med Biol; 2011 Dec; 56(23):7555-67. PubMed ID: 22080091
    [TBL] [Abstract][Full Text] [Related]  

  • 5. SU-E-I-63: Performance Study of An Electron-Tracking Compton Camera for Medical Imaging.
    Kabuki S; Kimura H; Kubo H; Ogawa K; Kunieda E; Tanimori T
    Med Phys; 2012 Jun; 39(6Part5):3639. PubMed ID: 28517628
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multi-modal 3D imaging of radionuclides using multiple hybrid Compton cameras.
    Omata A; Masubuchi M; Koshikawa N; Kataoka J; Kato H; Toyoshima A; Teramoto T; Ooe K; Liu Y; Matsunaga K; Kamiya T; Watabe T; Shimosegawa E; Hatazawa J
    Sci Rep; 2022 Feb; 12(1):2546. PubMed ID: 35169183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging.
    Kim SM
    Biomed Eng Lett; 2018 Nov; 8(4):383-392. PubMed ID: 30603223
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Compton imaging for medical applications.
    Tashima H; Yamaya T
    Radiol Phys Technol; 2022 Sep; 15(3):187-205. PubMed ID: 35867197
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera.
    Uenomachi M; Takahashi M; Shimazoe K; Takahashi H; Kamada K; Orita T; Ogane K; Tsuji AB
    Sci Rep; 2021 Sep; 11(1):17933. PubMed ID: 34504184
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development and performance verification of a 3-D position-sensitive Compton camera for imaging MeV gamma rays.
    Hosokoshi H; Kataoka J; Mochizuki S; Yoneyama M; Ito S; Kiji H; Nishi F; Miyamoto S; Shima T
    Sci Rep; 2019 Dec; 9(1):18551. PubMed ID: 31811186
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a pixelated GSO gamma camera system with tungsten parallel hole collimator for single photon imaging.
    Yamamoto S; Watabe H; Kanai Y; Shimosegawa E; Hatazawa J
    Med Phys; 2012 Feb; 39(2):581-8. PubMed ID: 22320767
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
    Habte F; Foudray AM; Olcott PD; Levin CS
    Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance evaluation of a pixellated Ge Compton camera.
    Alnaaimi MA; Royle GJ; Ghoggali W; Banoqitah E; Cullum I; Speller RD
    Phys Med Biol; 2011 Jun; 56(12):3473-86. PubMed ID: 21606554
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [New medical imaging based on electron tracking Compton camera (ETCC)].
    Tanimori T; Kubo H; Kabuki S; Kimura H
    Igaku Butsuri; 2012; 32(3):111-8. PubMed ID: 24592680
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Imaging performance comparison between a LaBr3: Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera.
    Russo P; Mettivier G; Pani R; Pellegrini R; Cinti MN; Bennati P
    Med Phys; 2009 Apr; 36(4):1298-317. PubMed ID: 19472638
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imaging.
    Han L; Rogers WL; Huh SS; Clinthorne N
    Phys Med Biol; 2008 Dec; 53(24):7029-45. PubMed ID: 19015578
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Precision imaging of 4.4 MeV gamma rays using a 3-D position sensitive Compton camera.
    Koide A; Kataoka J; Masuda T; Mochizuki S; Taya T; Sueoka K; Tagawa L; Fujieda K; Maruhashi T; Kurihara T; Inaniwa T
    Sci Rep; 2018 May; 8(1):8116. PubMed ID: 29802312
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional and multienergy gamma-ray simultaneous imaging by using a Si/CdTe Compton camera.
    Suzuki Y; Yamaguchi M; Odaka H; Shimada H; Yoshida Y; Torikai K; Satoh T; Arakawa K; Kawachi N; Watanabe S; Takeda S; Ishikawa SN; Aono H; Watanabe S; Takahashi T; Nakano T
    Radiology; 2013 Jun; 267(3):941-7. PubMed ID: 23418002
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spectroscopic Compton imaging of prompt gamma emission at the MeV energy range.
    Chen H; Chen-Mayer HH; Turkoglu DJ; Riley BK; Draeger E; Polf JP
    J Radioanal Nucl Chem; 2018 Oct; 318(1):241-246. PubMed ID: 31327884
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New devices for imaging in nuclear medicine.
    Pani R; Pellegrini R; Cinti MN; Trotta C; Bennati P; Betti M; De Vincentis G; Cusanno F; Garibaldi F; Ridolfi S; Majewsky S; Tsui BM
    Cancer Biother Radiopharm; 2004 Feb; 19(1):121-8. PubMed ID: 15068620
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.