These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 28525672)

  • 21. Clinical impact of aortic regurgitation after transcatheter aortic valve replacement: insights into the degree and acuteness of presentation.
    Jerez-Valero M; Urena M; Webb JG; Tamburino C; Munoz-Garcia AJ; Cheema A; Dager AE; Serra V; Amat-Santos IJ; Barbanti M; Immè S; Alonso Briales JH; Al Lawati H; Benitez LM; Cucalon AM; Garcia del Blanco B; Revilla A; Dumont E; Barbosa Ribeiro H; Nombela-Franco L; Bergeron S; Pibarot P; Rodés-Cabau J
    JACC Cardiovasc Interv; 2014 Sep; 7(9):1022-32. PubMed ID: 25234675
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Device success and 30-day clinical outcome in patients undergoing preimplant valvuloplasty in transfemoral versus omitting valvuloplasty in transapical transcatheter aortic valve replacement.
    Wong SC; Pawar S; Minutello RM; Horn EM; Skubas NJ; Devereux RB; Salemi A
    J Thorac Cardiovasc Surg; 2015 Nov; 150(5):1111-7. PubMed ID: 26277463
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Transcatheter aortic valve-in-surgical aortic valve implantation: current status and future perspectives.
    Lange R; Piazza N
    Eur J Cardiothorac Surg; 2013 Sep; 44(3):403-6. PubMed ID: 23946226
    [No Abstract]   [Full Text] [Related]  

  • 24. Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study.
    Grube E; Laborde JC; Gerckens U; Felderhoff T; Sauren B; Buellesfeld L; Mueller R; Menichelli M; Schmidt T; Zickmann B; Iversen S; Stone GW
    Circulation; 2006 Oct; 114(15):1616-24. PubMed ID: 17015786
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Percutaneous implantation of a biological valve in the aorta to treat aortic valve insufficiency -- a sheep study.
    Boudjemline Y; Bonnet D; Sidi D; Bonhoeffer P
    Med Sci Monit; 2002 Apr; 8(4):BR113-6. PubMed ID: 11951056
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Percutaneous aortic valve in severe valvular regurgitation caused by infective endocarditis.
    Presbitero P; Mennuni MG; Pagnotta P; Gasparini GL; Ramondo A
    Int J Cardiol; 2011 Aug; 151(1):e10-1. PubMed ID: 20303189
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Acute coronary occlusion by injured aortic valve during percutaneous coronary intervention.
    Akutagawa O; Kijima Y; Nakagawa Y; Hata T; Ishizaka T; Takahashi T
    Cardiovasc Interv Ther; 2012 Jan; 27(1):43-6. PubMed ID: 24122641
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Von Willebrand factor as a biological sensor of blood flow to monitor percutaneous aortic valve interventions.
    Van Belle E; Rauch A; Vincentelli A; Jeanpierre E; Legendre P; Juthier F; Hurt C; Banfi C; Rousse N; Godier A; Caron C; Elkalioubie A; Corseaux D; Dupont A; Zawadzki C; Delhaye C; Mouquet F; Schurtz G; Deplanque D; Chinetti G; Staels B; Goudemand J; Jude B; Lenting PJ; Susen S
    Circ Res; 2015 Mar; 116(7):1193-201. PubMed ID: 25670067
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transapical implantation of a second-generation transcatheter heart valve in patients with noncalcified aortic regurgitation.
    Seiffert M; Diemert P; Koschyk D; Schirmer J; Conradi L; Schnabel R; Blankenberg S; Reichenspurner H; Baldus S; Treede H
    JACC Cardiovasc Interv; 2013 Jun; 6(6):590-7. PubMed ID: 23683735
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Management of paravalvular regurgitation after Edwards SAPIEN transcatheter aortic valve replacement: management of paravalvular regurgitation after TAVR.
    Martinez CA; Singh V; O'Neill BP; Alfonso CE; Bilsker MS; Martinez Clark P; Williams D; Cohen MG; Heldman AW; O'Neill WW
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):300-11. PubMed ID: 23580318
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Use of the Lotus Transcatheter Valve to Treat Severe Native Aortic Regurgitation.
    Saraf S; Khawaja MZ; Hilling-Smith R; Dooley M; Cockburn J; Trivedi U; Hildick-Smith D
    Ann Thorac Surg; 2017 Apr; 103(4):e305-e307. PubMed ID: 28359483
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Percutaneous stent-mounted valve for treatment of aortic or pulmonary valve disease.
    Webb JG; Munt B; Makkar RR; Naqvi TZ; Dang N
    Catheter Cardiovasc Interv; 2004 Sep; 63(1):89-93. PubMed ID: 15343576
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Percutaneous aortic valve replacement using a W-model valved stent: a preliminary feasibility study in sheep.
    Bai Y; Zong GJ; Wang YY; Jiang HB; Li WP; Wu H; Zhao XX; Qin YW
    Chin Med J (Engl); 2009 Mar; 122(6):655-8. PubMed ID: 19323929
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of multislice computed tomography findings between bicuspid and tricuspid aortic valves before and after transcatheter aortic valve implantation.
    Watanabe Y; Chevalier B; Hayashida K; Leong T; Bouvier E; Arai T; Farge A; Hovasse T; Garot P; Cormier B; Morice MC; Lefèvre T
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):323-30. PubMed ID: 25594190
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Direct aortic transcatheter aortic valve implantation for pure aortic valve regurgitation after implantation of a left ventricular assist device.
    Krause R; Metz D; Bushnaq H
    J Thorac Cardiovasc Surg; 2014 Apr; 147(4):e38-41. PubMed ID: 24495901
    [No Abstract]   [Full Text] [Related]  

  • 36. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.
    Dvir D; Webb JG; Bleiziffer S; Pasic M; Waksman R; Kodali S; Barbanti M; Latib A; Schaefer U; Rodés-Cabau J; Treede H; Piazza N; Hildick-Smith D; Himbert D; Walther T; Hengstenberg C; Nissen H; Bekeredjian R; Presbitero P; Ferrari E; Segev A; de Weger A; Windecker S; Moat NE; Napodano M; Wilbring M; Cerillo AG; Brecker S; Tchetche D; Lefèvre T; De Marco F; Fiorina C; Petronio AS; Teles RC; Testa L; Laborde JC; Leon MB; Kornowski R;
    JAMA; 2014 Jul; 312(2):162-70. PubMed ID: 25005653
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.
    Patsalis PC; Al-Rashid F; Neumann T; Plicht B; Hildebrandt HA; Wendt D; Thielmann M; Jakob HG; Heusch G; Erbel R; Kahlert P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):965-71. PubMed ID: 24050862
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function.
    Delgado V; Ng AC; van de Veire NR; van der Kley F; Schuijf JD; Tops LF; de Weger A; Tavilla G; de Roos A; Kroft LJ; Schalij MJ; Bax JJ
    Eur Heart J; 2010 May; 31(9):1114-23. PubMed ID: 20173197
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Experimental evaluation of the JenaClip transcatheter aortic valve.
    Lauten A; Ferrari M; Petri A; Ensminger SM; Gummert JF; Boudjemline Y; Schubert H; Schumm J; Hekmat K; Schlosser M; Figulla HR
    Catheter Cardiovasc Interv; 2009 Sep; 74(3):514-9. PubMed ID: 19434747
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.