BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

437 related articles for article (PubMed ID: 28527236)

  • 1. A weighted difference of L1 and L2 on the gradient minimization based on alternating direction method for circular computed tomography.
    Lu W; Li L; Cai A; Zhang H; Wang L; Yan B
    J Xray Sci Technol; 2017; 25(5):813-829. PubMed ID: 28527236
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Low dose CT reconstruction via L1 norm dictionary learning using alternating minimization algorithm and balancing principle.
    Wu J; Dai F; Hu G; Mou X
    J Xray Sci Technol; 2018; 26(4):603-622. PubMed ID: 29689766
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization-based image reconstruction in computed tomography by alternating direction method with ordered subsets.
    Cai A; Wang L; Li L; Yan B; Zheng Z; Zhang H; Zhang W; Lu W; Hu G
    J Xray Sci Technol; 2017; 25(3):429-464. PubMed ID: 28157114
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Edge guided image reconstruction in linear scan CT by weighted alternating direction TV minimization.
    Cai A; Wang L; Zhang H; Yan B; Li L; Xi X; Li J
    J Xray Sci Technol; 2014; 22(3):335-49. PubMed ID: 24865209
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Iterative CT reconstruction via minimizing adaptively reweighted total variation.
    Zhu L; Niu T; Petrongolo M
    J Xray Sci Technol; 2014; 22(2):227-40. PubMed ID: 24699349
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Locally linear transform based three-dimensional gradient
    Wang Q; Wu W; Deng S; Zhu Y; Yu H
    Med Phys; 2020 Oct; 47(10):4810-4826. PubMed ID: 32740956
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fast and Robust Reconstruction for Fluorescence Molecular Tomography via
    Zhang H; Geng G; Wang X; Qu X; Hou Y; He X
    Biomed Res Int; 2016; 2016():5065217. PubMed ID: 28050563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low-dose CT reconstruction via L1 dictionary learning regularization using iteratively reweighted least-squares.
    Zhang C; Zhang T; Li M; Peng C; Liu Z; Zheng J
    Biomed Eng Online; 2016 Jun; 15(1):66. PubMed ID: 27316680
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A separable quadratic surrogate total variation minimization algorithm for accelerating accurate CT reconstruction from few-views and limited-angle data.
    Hou X; Teng Y; Kang Y; Qi S
    Med Phys; 2018 Feb; 45(2):535-548. PubMed ID: 29171030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficient solving algorithm for determining the exact sampling condition of limited-angle computed tomography reconstruction.
    Li Z; Wang L; Zhang W; Cai A; Li L; Liang N; Yan B
    J Xray Sci Technol; 2019; 27(2):371-388. PubMed ID: 30856151
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ℓ0 Gradient Minimization Based Image Reconstruction for Limited-Angle Computed Tomography.
    Yu W; Zeng L
    PLoS One; 2015; 10(7):e0130793. PubMed ID: 26158543
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-local total-variation (NLTV) minimization combined with reweighted L1-norm for compressed sensing CT reconstruction.
    Kim H; Chen J; Wang A; Chuang C; Held M; Pouliot J
    Phys Med Biol; 2016 Sep; 61(18):6878-6891. PubMed ID: 27589006
    [TBL] [Abstract][Full Text] [Related]  

  • 13. NUFFT-Based Iterative Image Reconstruction via Alternating Direction Total Variation Minimization for Sparse-View CT.
    Yan B; Jin Z; Zhang H; Li L; Cai A
    Comput Math Methods Med; 2015; 2015():691021. PubMed ID: 26120355
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A TV-minimization image-reconstruction algorithm without system matrix.
    Qiao Z; Lu Y
    J Xray Sci Technol; 2021; 29(5):851-865. PubMed ID: 34308898
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficient and robust 3D CT image reconstruction based on total generalized variation regularization using the alternating direction method.
    Chen J; Wang L; Yan B; Zhang H; Cheng G
    J Xray Sci Technol; 2015; 23(6):683-99. PubMed ID: 26756406
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A few-view reweighted sparsity hunting (FRESH) method for CT image reconstruction.
    Chang M; Li L; Chen Z; Xiao Y; Zhang L; Wang G
    J Xray Sci Technol; 2013; 21(2):161-76. PubMed ID: 23694909
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Edge-preserving reconstruction from sparse projections of limited-angle computed tomography using ℓ
    Yu W; Wang C; Huang M
    Rev Sci Instrum; 2017 Apr; 88(4):043703. PubMed ID: 28456252
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Efficient TpV minimization for circular, cone-beam computed tomography reconstruction via non-convex optimization.
    Cai A; Wang L; Yan B; Li L; Zhang H; Hu G
    Comput Med Imaging Graph; 2015 Oct; 45():1-10. PubMed ID: 26233922
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sparse-view image reconstruction via total absolute curvature combining total variation for X-ray computed tomography.
    Zheng Z; Cai A; Li L; Yan B; Le F; Wang L; Hu G
    J Xray Sci Technol; 2017; 25(6):959-980. PubMed ID: 28697576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Constrained T
    Sidky EY; Chartrand R; Boone JM; Pan X
    IEEE J Transl Eng Health Med; 2014 Jun; 2():. PubMed ID: 25401059
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.