These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

549 related articles for article (PubMed ID: 28542094)

  • 1. Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography With Suboptimal Contrast Attenuation.
    Leithner D; Wichmann JL; Vogl TJ; Trommer J; Martin SS; Scholtz JE; Bodelle B; De Cecco CN; Duguay T; Nance JW; Schoepf UJ; Albrecht MH
    Invest Radiol; 2017 Nov; 52(11):659-665. PubMed ID: 28542094
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen.
    Albrecht MH; Trommer J; Wichmann JL; Scholtz JE; Martin SS; Lehnert T; Vogl TJ; Bodelle B
    Invest Radiol; 2016 Sep; 51(9):582-90. PubMed ID: 26953565
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary Embolism in Portal-Venous Phase Dual-Energy Computed Tomography.
    Weiss J; Notohamiprodjo M; Bongers M; Schabel C; Mangold S; Nikolaou K; Bamberg F; Othman AE
    Invest Radiol; 2017 Mar; 52(3):142-147. PubMed ID: 27548345
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions.
    De Cecco CN; Caruso D; Schoepf UJ; De Santis D; Muscogiuri G; Albrecht MH; Meinel FG; Wichmann JL; Burchett PF; Varga-Szemes A; Sheafor DH; Hardie AD
    Eur Radiol; 2018 Aug; 28(8):3393-3404. PubMed ID: 29460075
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography.
    D'Angelo T; Bucher AM; Lenga L; Arendt CT; Peterke JL; Caruso D; Mazziotti S; Blandino A; Ascenti G; Othman AE; Martin SS; Leithner D; Vogl TJ; Wichmann JL
    Eur Radiol; 2018 Apr; 28(4):1393-1401. PubMed ID: 29018926
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT.
    Bae K; Jeon KN; Cho SB; Park SE; Moon JI; Baek HJ; Choi BH
    AJR Am J Roentgenol; 2018 Apr; 210(4):734-741. PubMed ID: 29446668
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging.
    Lenga L; Czwikla R; Wichmann JL; Leithner D; Albrecht MH; Booz C; Arendt CT; Yel I; D'Angelo T; Vogl TJ; Martin SS
    Eur J Radiol; 2018 Sep; 106():184-191. PubMed ID: 30150043
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography.
    Meier A; Wurnig M; Desbiolles L; Leschka S; Frauenfelder T; Alkadhi H
    Clin Radiol; 2015 Nov; 70(11):1244-51. PubMed ID: 26231468
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement.
    Martin SS; Albrecht MH; Wichmann JL; Hüsers K; Scholtz JE; Booz C; Bodelle B; Bauer RW; Metzger SC; Vogl TJ; Lehnert T
    Eur Radiol; 2017 Feb; 27(2):705-714. PubMed ID: 27236818
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis.
    Leithner D; Mahmoudi S; Wichmann JL; Martin SS; Lenga L; Albrecht MH; Booz C; Arendt CT; Beeres M; D'Angelo T; Bodelle B; Vogl TJ; Scholtz JE
    Eur J Radiol; 2018 Feb; 99():111-117. PubMed ID: 29362140
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noise-optimized advanced image-based virtual monoenergetic imaging for improved visualization of lung cancer: Comparison with traditional virtual monoenergetic imaging.
    Frellesen C; Kaup M; Wichmann JL; Hüsers K; Scholtz JE; Albrecht MH; Metzger SC; Bauer RW; Kerl JM; Lehnert T; Vogl TJ; Bodelle B
    Eur J Radiol; 2016 Mar; 85(3):665-72. PubMed ID: 26860682
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual-energy computed tomography in patients with cutaneous malignant melanoma: Comparison of noise-optimized and traditional virtual monoenergetic imaging.
    Martin SS; Wichmann JL; Weyer H; Albrecht MH; D'Angelo T; Leithner D; Lenga L; Booz C; Scholtz JE; Bodelle B; Vogl TJ; Hammerstingl R
    Eur J Radiol; 2017 Oct; 95():1-8. PubMed ID: 28987652
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma.
    Martin SS; Wichmann JL; Pfeifer S; Leithner D; Lenga L; Reynolds MA; D'Angelo T; Hammerstingl R; Gruber-Rouh T; Vogl TJ; Albrecht MH
    Eur J Radiol; 2017 Dec; 97():1-7. PubMed ID: 29153358
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors.
    Martin SS; Pfeifer S; Wichmann JL; Albrecht MH; Leithner D; Lenga L; Scholtz JE; Vogl TJ; Bodelle B
    Abdom Radiol (NY); 2017 Mar; 42(3):718-726. PubMed ID: 27999889
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in head and neck cancer.
    Wichmann JL; Nöske EM; Kraft J; Burck I; Wagenblast J; Eckardt A; Frellesen C; Kerl JM; Bauer RW; Bodelle B; Lehnert T; Vogl TJ; Schulz B
    Invest Radiol; 2014 Nov; 49(11):735-41. PubMed ID: 24872006
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy.
    Wichmann JL; Gillott MR; De Cecco CN; Mangold S; Varga-Szemes A; Yamada R; Otani K; Canstein C; Fuller SR; Vogl TJ; Todoran TM; Schoepf UJ
    Invest Radiol; 2016 Feb; 51(2):139-46. PubMed ID: 26561048
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography.
    Ghandour A; Sher A; Rassouli N; Dhanantwari A; Rajiah P
    J Comput Assist Tomogr; 2018; 42(6):858-865. PubMed ID: 29659426
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual-Energy Computed Tomography Pulmonary Angiography: Comparison of Vessel Enhancement between Linear Blended and Virtual Monoenergetic Reconstruction Techniques.
    Murphy A; Cheng J; Pratap J; Redman R; Coucher J
    J Med Imaging Radiat Sci; 2019 Mar; 50(1):62-67. PubMed ID: 30777250
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen.
    Martin SS; Wichmann JL; Scholtz JE; Leithner D; D'Angelo T; Weyer H; Booz C; Lenga L; Vogl TJ; Albrecht MH
    J Vasc Interv Radiol; 2017 Sep; 28(9):1257-1266. PubMed ID: 28734847
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noise-optimized virtual monoenergetic reconstructions of dual-energy CT angiographies improve assessability of the lower leg arterial segments in peripheral arterial occlusive disease.
    Gruschwitz P; Petritsch B; Schmid A; Schmidt AMA; Grunz JP; Kuhl PJ; Heidenreich JF; Huflage H; Bley TA; Kosmala A
    Radiography (Lond); 2023 Jan; 29(1):19-27. PubMed ID: 36209641
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.