These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 28549600)
21. Validating a clinical measure of levator hiatus size. Boyles SH; Edwards SR; Gregory WT; Denman MA; Clark AL Am J Obstet Gynecol; 2007 Feb; 196(2):174.e1-4. PubMed ID: 17306670 [TBL] [Abstract][Full Text] [Related]
22. Agreement and reliability of pelvic floor measurements during rest and on maximum Valsalva maneuver using three-dimensional translabial ultrasound and virtual reality imaging. Speksnijder L; Oom DM; Koning AH; Biesmeijer CS; Steegers EA; Steensma AB Ultrasound Obstet Gynecol; 2016 Aug; 48(2):243-9. PubMed ID: 26483139 [TBL] [Abstract][Full Text] [Related]
23. Intra-rater reliability and diagnostic accuracy of a new vaginal dynamometer to measure pelvic floor muscle strength in women with urinary incontinence. Romero-Cullerés G; Peña-Pitarch E; Jané-Feixas C; Arnau A; Montesinos J; Abenoza-Guardiola M Neurourol Urodyn; 2017 Feb; 36(2):333-337. PubMed ID: 26584652 [TBL] [Abstract][Full Text] [Related]
24. The assessment of levator trauma: a comparison between palpation and 4D pelvic floor ultrasound. Dietz HP; Hyland G; Hay-Smith J Neurourol Urodyn; 2006; 25(5):424-7. PubMed ID: 16721815 [TBL] [Abstract][Full Text] [Related]
25. Reliability of new three-dimensional ultrasound technique for pelvic hiatal area measurement. Youssef A; Montaguti E; Sanlorenzo O; Cariello L; Salsi G; Morganelli G; Azzarone C; Pilu G; Rizzo N Ultrasound Obstet Gynecol; 2016 May; 47(5):629-35. PubMed ID: 26105710 [TBL] [Abstract][Full Text] [Related]
26. Reliability and validity of pelvic floor muscle strength assessment using the MizCure perineometer. Abe-Takahashi Y; Kitta T; Ouchi M; Okayauchi M; Chiba H; Higuchi M; Togo M; Shinohara N BMC Womens Health; 2020 Nov; 20(1):257. PubMed ID: 33213429 [TBL] [Abstract][Full Text] [Related]
27. Test-retest reliability of an instrumented speculum for measuring vaginal closure force. Miller JM; Ashton-Miller JA; Perruchini D; DeLancey JO Neurourol Urodyn; 2007; 26(6):858-63. PubMed ID: 17357114 [TBL] [Abstract][Full Text] [Related]
28. Reliability and differentiation of pelvic floor muscle electromyography measurements in healthy volunteers using a new device: the Multiple Array Probe Leiden (MAPLe). Voorham-van der Zalm PJ; Voorham JC; van den Bos TW; Ouwerkerk TJ; Putter H; Wasser MN; Webb A; DeRuiter MC; Pelger RC Neurourol Urodyn; 2013 Apr; 32(4):341-8. PubMed ID: 22972554 [TBL] [Abstract][Full Text] [Related]
29. Comparative assessment of pelvic floor function using vaginal cones, vaginal digital palpation and vaginal pressure measurements. Hahn I; Milsom I; Ohlsson BL; Ekelund P; Uhlemann C; Fall M Gynecol Obstet Invest; 1996; 41(4):269-74. PubMed ID: 8793498 [TBL] [Abstract][Full Text] [Related]
30. Direction sensitive sensor probe for the evaluation of voluntary and reflex pelvic floor contractions. Constantinou CE; Omata S Neurourol Urodyn; 2007; 26(3):386-91. PubMed ID: 17301962 [TBL] [Abstract][Full Text] [Related]
31. Assessment of pelvic floor muscle contraction with palpation, perineometry and transperineal ultrasound: a cross-sectional study. Volløyhaug I; Mørkved S; Salvesen Ø; Salvesen KÅ Ultrasound Obstet Gynecol; 2016 Jun; 47(6):768-73. PubMed ID: 26300128 [TBL] [Abstract][Full Text] [Related]
32. Development and testing of a vaginal pressure sensor to measure intra-abdominal pressure in women. Rosenbluth EM; Johnson PJ; Hitchcock RW; Nygaard IE Neurourol Urodyn; 2010 Apr; 29(4):532-5. PubMed ID: 19693948 [TBL] [Abstract][Full Text] [Related]
33. Relationship between intra-abdominal pressure and vaginal wall movements during Valsalva in women with and without pelvic organ prolapse: technique development and early observations. Spahlinger DM; Newcomb L; Ashton-Miller JA; DeLancey JO; Chen L Int Urogynecol J; 2014 Jul; 25(7):873-81. PubMed ID: 24474605 [TBL] [Abstract][Full Text] [Related]
34. A comparison of perineometer to brink score for assessment of pelvic floor muscle strength. Hundley AF; Wu JM; Visco AG Am J Obstet Gynecol; 2005 May; 192(5):1583-91. PubMed ID: 15902162 [TBL] [Abstract][Full Text] [Related]
35. Initial experience with a new method for the dynamic assessment of pelvic floor function in women: the Kolpexin Pull Test. Guerette N; Neimark M; Kopka SL; Jones JE; Davila GW Int Urogynecol J Pelvic Floor Dysfunct; 2004; 15(1):39-43; discussion 43. PubMed ID: 14752597 [TBL] [Abstract][Full Text] [Related]
36. Reliability of the PERFECT scheme assessed by unidigital and bidigital vaginal palpation. da Silva JB; de Godoi Fernandes JG; Caracciolo BR; Zanello SC; de Oliveira Sato T; Driusso P Int Urogynecol J; 2021 Dec; 32(12):3199-3207. PubMed ID: 33416969 [TBL] [Abstract][Full Text] [Related]