These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 28550903)

  • 1. Hemodynamic effects of the Abdominal Aortic and Junctional Tourniquet in a hemorrhagic swine model.
    Rall JM; Ross JD; Clemens MS; Cox JM; Buckley TA; Morrison JJ
    J Surg Res; 2017 May; 212():159-166. PubMed ID: 28550903
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Long-term consequences of abdominal aortic and junctional tourniquet for hemorrhage control.
    Kheirabadi BS; Terrazas IB; Miranda N; Voelker AN; Klemcke HG; Brown AW; Dubick MA
    J Surg Res; 2018 Nov; 231():99-108. PubMed ID: 30278975
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Use of the Abdominal Aortic and Junctional Tourniquet During Cardiopulmonary Resuscitation Following Traumatic Cardiac Arrest in Swine.
    Rall J; Cox JM; Maddry J
    Mil Med; 2017 Sep; 182(9):e2001-e2005. PubMed ID: 28885969
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of zone 3 Resuscitative Endovascular Balloon Occlusion of the Aorta and the Abdominal Aortic and Junctional Tourniquet in a model of junctional hemorrhage in swine.
    Rall JM; Redman TT; Ross EM; Morrison JJ; Maddry JK
    J Surg Res; 2018 Jun; 226():31-39. PubMed ID: 29661286
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Abdominal aortic and junctional tourniquet versus zone III resuscitative endovascular balloon occlusion of the aorta in a swine junctional hemorrhage model.
    Schechtman DW; Kauvar DS; De Guzman R; Polykratis IA; Prince MD; Kheirabadi BS; Dubick MA
    J Trauma Acute Care Surg; 2020 Feb; 88(2):292-297. PubMed ID: 31999656
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Increased crystalloid fluid requirements during zone 3 Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) versus Abdominal Aortic and Junctional Tourniquet (AAJT) after class II hemorrhage in swine.
    Brännström A; Dahlquist A; Gustavsson J; Arborelius UP; Günther M
    Eur J Trauma Emerg Surg; 2022 Feb; 48(1):335-344. PubMed ID: 33515048
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Minimally invasive preperitoneal balloon tamponade and abdominal aortic junctional tourniquet versus open packing for pelvic fracture-associated hemorrhage: Not all extrinsic compression is equal.
    Do WS; Forte DM; Sheldon RR; Weiss JB; Barron MR; Sokol KK; Black GE; Hegge SR; Eckert MJ; Martin MJ
    J Trauma Acute Care Surg; 2019 Apr; 86(4):625-634. PubMed ID: 30633092
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Physiological Consequences of Abdominal Aortic and Junctional Tourniquet (AAJT) Application to Control Hemorrhage in a Swine Model.
    Kheirabadi BS; Terrazas IB; Miranda N; Voelker AN; Grimm R; Kragh JF; Dubick MA
    Shock; 2016 Sep; 46(3 Suppl 1):160-6. PubMed ID: 27172149
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Abdominal Aortic and Junctional Tourniquet release after 240 minutes is survivable and associated with small intestine and liver ischemia after porcine class II hemorrhage.
    Brännström A; Rocksén D; Hartman J; Nyman N; Gustavsson J; Arborelius UP; Günther M
    J Trauma Acute Care Surg; 2018 Oct; 85(4):717-724. PubMed ID: 29985233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Use of the Abdominal Aortic and Junctional Tourniquet Versus Combat Gauze in a Porcine Hemicorporectomy Model.
    Schwartz RB; Shiver SA; Reynolds BZ; Lowry J; Holsten SB; Akers TW; Lyon M
    J Spec Oper Med; 2019; 19(2):69-72. PubMed ID: 31201753
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Conversion of the Abdominal Aortic and Junctional Tourniquet (AAJT) to Infrarenal Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) Is Practical in a Swine Hemorrhage Model.
    Stigall K; Blough PE; Rall JM; Kauvar DS
    J Spec Oper Med; 2021; 21(1):30-36. PubMed ID: 33721303
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy of the Abdominal Aortic Junctional Tourniquet-Torso Plate in a Lethal Model of Noncompressible Torso Hemorrhage.
    Bonanno AM; Hoops HE; Graham T; Davis BL; McCully BH; Wilson LN; Madtson BM; Ross JD
    J Spec Oper Med; 2018; 18(4):106-110. PubMed ID: 30566733
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transition from abdominal aortic and junctional tourniquet to zone 3 resuscitative endovascular balloon occlusion of the aorta is feasible with hemodynamic support after porcine class IV hemorrhage.
    Brännström A; Dahlquist A; Gustavsson J; Arborelius UP; Günther M
    J Trauma Acute Care Surg; 2019 Oct; 87(4):849-855. PubMed ID: 31589194
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of the Abdominal Aortic and Junctional Tourniquet on chest compressions in a swine model of ventricular fibrillation.
    Hewitt CW; Pombo MA; Blough PE; Castaneda MG; Percival TJ; Rall JM
    Am J Emerg Med; 2021 Jul; 45():297-302. PubMed ID: 33046311
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Differing Resuscitation With Aortic Occlusion in a Swine Junctional Hemorrhage Polytrauma Model.
    Schechtman DW; Kauvar DS; De Guzman R; Polykratis IA; Prince MD; Kheirabadi BS; Dubick MA
    J Surg Res; 2020 Apr; 248():90-97. PubMed ID: 31877435
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A prospective, randomized trial of intravenous hydroxocobalamin versus whole blood transfusion compared to no treatment for Class III hemorrhagic shock resuscitation in a prehospital swine model.
    Bebarta VS; Garrett N; Boudreau S; Castaneda M
    Acad Emerg Med; 2015 Mar; 22(3):321-30. PubMed ID: 25731610
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prehospital aortic blood flow control techniques for non-compressible traumatic hemorrhage.
    Shi C; Li S; Wang Z; Shen H
    Injury; 2021 Jul; 52(7):1657-1663. PubMed ID: 33750584
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of a Novel Abdominal Aortic and Junctional Tourniquet to Reduce or Eliminate Flow in the Brachial and Popliteal Arteries in Human Subjects.
    Lyon M; Johnson D; Gordon R
    Prehosp Emerg Care; 2015; 19(3):405-8. PubMed ID: 25494652
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Smartphone-based mobile thermal imaging technology to assess limb perfusion and tourniquet effectiveness under normal and blackout conditions.
    Barron MR; Kuckelman JP; McClellan JM; Derickson MJ; Phillips CJ; Marko ST; Smith JP; Eckert MJ; Martin MJ
    J Trauma Acute Care Surg; 2017 Dec; 83(6):1129-1135. PubMed ID: 28697026
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Testing of Junctional Tourniquets by Medics of the Israeli Defense Force in Control of Simulated Groin Hemorrhage.
    Chen J; Benov A; Nadler R; Landau G; Sorkin A; Aden JK; Kragh JF; Glassberg E
    J Spec Oper Med; 2016; 16(1):36-42. PubMed ID: 27045492
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.