These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
345 related articles for article (PubMed ID: 28551828)
1. Rate and mode of screw misplacements after 3D-fluoroscopy navigation-assisted insertion and 3D-imaging control of 1547 pedicle screws in spinal levels T10-S1 related to vertebrae and spinal sections. Balling H; Blattert TR Eur Spine J; 2017 Nov; 26(11):2898-2905. PubMed ID: 28551828 [TBL] [Abstract][Full Text] [Related]
3. Learning curve of 3D fluoroscopy image-guided pedicle screw placement in the thoracolumbar spine. Ryang YM; Villard J; Obermüller T; Friedrich B; Wolf P; Gempt J; Ringel F; Meyer B Spine J; 2015 Mar; 15(3):467-76. PubMed ID: 25315133 [TBL] [Abstract][Full Text] [Related]
4. Clinical outcomes following spinal fusion using an intraoperative computed tomographic 3D imaging system. Xiao R; Miller JA; Sabharwal NC; Lubelski D; Alentado VJ; Healy AT; Mroz TE; Benzel EC J Neurosurg Spine; 2017 May; 26(5):628-637. PubMed ID: 28291408 [TBL] [Abstract][Full Text] [Related]
5. Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis. Dea N; Fisher CG; Batke J; Strelzow J; Mendelsohn D; Paquette SJ; Kwon BK; Boyd MD; Dvorak MF; Street JT Spine J; 2016 Jan; 16(1):23-31. PubMed ID: 26456854 [TBL] [Abstract][Full Text] [Related]
6. Revision Rate of Misplaced Pedicle Screws of the Thoracolumbar Spine-Comparison of Three-Dimensional Fluoroscopy Navigation with Freehand Placement: A Systematic Analysis and Review of the Literature. Fichtner J; Hofmann N; Rienmüller A; Buchmann N; Gempt J; Kirschke JS; Ringel F; Meyer B; Ryang YM World Neurosurg; 2018 Jan; 109():e24-e32. PubMed ID: 28951183 [TBL] [Abstract][Full Text] [Related]
7. Comparison of novel machine vision spinal image guidance system with existing 3D fluoroscopy-based navigation system: a randomized prospective study. Malham GM; Munday NR Spine J; 2022 Apr; 22(4):561-569. PubMed ID: 34666179 [TBL] [Abstract][Full Text] [Related]
8. Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder-a technical note and case series. Tsuang FY; Chen CH; Kuo YJ; Tseng WL; Chen YS; Lin CJ; Liao CJ; Lin FH; Chiang CJ Spine J; 2017 Sep; 17(9):1373-1380. PubMed ID: 28645672 [TBL] [Abstract][Full Text] [Related]
9. Time Demand and Radiation Dose in 3D-Fluoroscopy-based Navigation-assisted 3D-Fluoroscopy-controlled Pedicle Screw Instrumentations. Balling H Spine (Phila Pa 1976); 2018 May; 43(9):E512-E519. PubMed ID: 28922280 [TBL] [Abstract][Full Text] [Related]
11. The accuracy of pedicle screw placement using intraoperative image guidance systems. Mason A; Paulsen R; Babuska JM; Rajpal S; Burneikiene S; Nelson EL; Villavicencio AT J Neurosurg Spine; 2014 Feb; 20(2):196-203. PubMed ID: 24358998 [TBL] [Abstract][Full Text] [Related]
12. Fluoroscopy-Assisted Freehand Versus 3D-Navigated Imaging-Assisted Pedicle Screw Insertion: A Multicenter Study. Cammarata G; Scalia G; Costanzo R; Umana GE; Furnari M; Ponzo G; Giuffrida M; Maugeri R; Iacopino DG; Nicoletti GF; Graziano F Acta Neurochir Suppl; 2023; 135():425-430. PubMed ID: 38153504 [TBL] [Abstract][Full Text] [Related]
13. Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. Ito Y; Sugimoto Y; Tomioka M; Hasegawa Y; Nakago K; Yagata Y J Neurosurg Spine; 2008 Nov; 9(5):450-3. PubMed ID: 18976176 [TBL] [Abstract][Full Text] [Related]
14. Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation. Chachan S; Bin Abd Razak HR; Loo WL; Allen JC; Shree Kumar D Eur Spine J; 2018 Nov; 27(11):2729-2736. PubMed ID: 29651593 [TBL] [Abstract][Full Text] [Related]
15. Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement. Tajsic T; Patel K; Farmer R; Mannion RJ; Trivedi RA Eur Spine J; 2018 Aug; 27(8):1918-1924. PubMed ID: 29667139 [TBL] [Abstract][Full Text] [Related]
16. Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. Ishikawa Y; Kanemura T; Yoshida G; Matsumoto A; Ito Z; Tauchi R; Muramoto A; Ohno S; Nishimura Y J Neurosurg Spine; 2011 Nov; 15(5):472-8. PubMed ID: 21761967 [TBL] [Abstract][Full Text] [Related]
17. Intraoperative image guidance compared with free-hand methods in adolescent idiopathic scoliosis posterior spinal surgery: a systematic review on screw-related complications and breach rates. Chan A; Parent E; Narvacan K; San C; Lou E Spine J; 2017 Sep; 17(9):1215-1229. PubMed ID: 28428081 [TBL] [Abstract][Full Text] [Related]
18. Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Austin MS; Vaccaro AR; Brislin B; Nachwalter R; Hilibrand AS; Albert TJ Spine (Phila Pa 1976); 2002 Nov; 27(22):2503-8. PubMed ID: 12435982 [TBL] [Abstract][Full Text] [Related]
19. Ultrasound-based navigated pedicle screw insertion without intraoperative radiation: feasibility study on porcine cadavers. Gueziri HE; Georgiopoulos M; Santaguida C; Collins DL Spine J; 2022 Aug; 22(8):1408-1417. PubMed ID: 35523390 [TBL] [Abstract][Full Text] [Related]
20. Combining pedicle screw stimulation with spinal navigation, a protocol to maximize the safety of neural elements and minimize radiation exposure in thoracolumbar spine instrumentation. Kassis SZ; Abukwedar LK; Msaddi AK; Majer CN; Othman W Eur Spine J; 2016 Jun; 25(6):1724-8. PubMed ID: 25921653 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]