These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 28552926)

  • 1. Modelling and structural analysis of skull/cranial implant: beyond mid-line deformities.
    Bogu VP; Kumar YR; Kumar Khanara A
    Acta Bioeng Biomech; 2017; 19(1):125-131. PubMed ID: 28552926
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Homogenous scaffold-based cranial/skull implant modelling and structural analysis-unit cell algorithm-meshless approach.
    Phanindra Bogu V; Ravi Kumar Y; Kumar Khanra A
    Med Biol Eng Comput; 2017 Nov; 55(11):2053-2065. PubMed ID: 28474182
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: A finite element analysis comparing titanium and PEEK.
    Carpenter RD; Klosterhoff BS; Torstrick FB; Foley KT; Burkus JK; Lee CSD; Gall K; Guldberg RE; Safranski DL
    J Mech Behav Biomed Mater; 2018 Apr; 80():68-76. PubMed ID: 29414477
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Alloplastic Cranioplasty Reconstruction: A Systematic Review Comparing Outcomes With Titanium Mesh, Polymethyl Methacrylate, Polyether Ether Ketone, and Norian Implants in 3591 Adult Patients.
    Oliver JD; Banuelos J; Abu-Ghname A; Vyas KS; Sharaf B
    Ann Plast Surg; 2019 May; 82(5S Suppl 4):S289-S294. PubMed ID: 30973834
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical behaviour of reconstructed defected skull with custom PEEK implant and Titanium fixture plates under dynamic loading conditions using FEM.
    Jindal P; Bharti J; Gupta V; Dhami SS
    J Mech Behav Biomed Mater; 2023 Oct; 146():106063. PubMed ID: 37556925
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [PEEK customized implant for skull esthetic reconstruction].
    Foletti JM; Lari N; Dumas P; Compes P; Guyot L
    Rev Stomatol Chir Maxillofac; 2012 Dec; 113(6):468-71. PubMed ID: 23182690
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cranioplasty with customized titanium and PEEK implants in a mechanical stress model.
    Lethaus B; Safi Y; ter Laak-Poort M; Kloss-Brandstätter A; Banki F; Robbenmenke C; Steinseifer U; Kessler P
    J Neurotrauma; 2012 Apr; 29(6):1077-83. PubMed ID: 22017579
    [TBL] [Abstract][Full Text] [Related]  

  • 8. FEM assisted evaluation of PMMA and Ti6Al4V as materials for cranioplasty resulting mechanical behaviour and the neurocranial protection.
    Tsouknidas A; Maropoulos S; Savvakis S; Michailidis N
    Biomed Mater Eng; 2011; 21(3):139-47. PubMed ID: 22072078
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The potential of the three-dimensional printed titanium mesh implant for cranioplasty surgery applications: Biomechanical behaviors and surface properties.
    Huang MT; Juan PK; Chen SY; Wu CJ; Wen SC; Cho YC; Huang MS; Chou HH; Ou KL
    Mater Sci Eng C Mater Biol Appl; 2019 Apr; 97():412-419. PubMed ID: 30678927
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [First Experience with Cranioplasty Using the Polyetheretherketone (PEEK) Implant - Retrospective Five-Year Follow-up Study].
    Šámal F; Ouzký M; Strnad J; Haninec P; Linzer P; Filip M
    Acta Chir Orthop Traumatol Cech; 2019; 86(6):431-434. PubMed ID: 31941571
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Finite element analysis of 6 large PMMA skull reconstructions: A multi-criteria evaluation approach.
    Ridwan-Pramana A; Marcián P; Borák L; Narra N; Forouzanfar T; Wolff J
    PLoS One; 2017; 12(6):e0179325. PubMed ID: 28609471
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical characterization and numerical simulation of polyether-ether-ketone (PEEK) cranial implants.
    El Halabi F; Rodriguez JF; Rebolledo L; Hurtós E; Doblaré M
    J Mech Behav Biomed Mater; 2011 Nov; 4(8):1819-32. PubMed ID: 22098881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Using rapid prototyping molds to create patient specific polymethylmethacrylate implants in cranioplasty.
    Gerber N; Stieglitz L; Peterhans M; Nolte LP; Raabe A; Weber S
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():3357-60. PubMed ID: 21097234
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental Modeling of Cranial Injury and Defect Reconstruction Using Superconstructive Polymers (PEEK).
    Shakova FM; Romanova GA; Khashirova SY; Vindizheva AS; Mashukov KV; Gulyaev MV; Semenova ZB
    Bull Exp Biol Med; 2024 May; 177(1):155-161. PubMed ID: 38963597
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design of customized implants and 3D printing of symmetric and asymmetric cranial cavities.
    Singh HN; Agrawal S; Kuthe AM
    J Mech Behav Biomed Mater; 2023 Oct; 146():106061. PubMed ID: 37544200
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mesh Ti6Al4V Material Manufactured by Selective Laser Melting (SLM) as a Promising Intervertebral Fusion Cage.
    Przekora A; Kazimierczak P; Wojcik M; Chodorski E; Kropiwnicki J
    Int J Mol Sci; 2022 Apr; 23(7):. PubMed ID: 35409345
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis.
    Anguiano-Sanchez J; Martinez-Romero O; Siller HR; Diaz-Elizondo JA; Flores-Villalba E; Rodriguez CA
    Comput Math Methods Med; 2016; 2016():6183679. PubMed ID: 27051460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computed-tomography modeled polyether ether ketone (PEEK) implants in revision cranioplasty.
    O'Reilly EB; Barnett S; Madden C; Welch B; Mickey B; Rozen S
    J Plast Reconstr Aesthet Surg; 2015 Mar; 68(3):329-38. PubMed ID: 25541423
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cranial reconstruction with prefabricated 3D implant after a gunshot injury: A case report.
    Malivuković A; Novaković N; Lepić M; Minić L; Stepić N; Đorđević B; Rasulić L
    Vojnosanit Pregl; 2016 Aug; 73(8):783-7. PubMed ID: 29328616
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polyether Ether Ketone Cranioplasties Are Permeable to Diagnostic Ultrasound.
    Mursch K; Behnke-Mursch J
    World Neurosurg; 2018 Sep; 117():142-143. PubMed ID: 29920388
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.