These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 2855365)

  • 21. The mucosal attachment at different abutments. An experimental study in dogs.
    Abrahamsson I; Berglundh T; Glantz PO; Lindhe J
    J Clin Periodontol; 1998 Sep; 25(9):721-7. PubMed ID: 9763327
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The use of durapatite ceramic implant in a periodontal-prosthetic case.
    Minichetti JC
    Gen Dent; 1990; 38(4):296-301. PubMed ID: 1963866
    [No Abstract]   [Full Text] [Related]  

  • 23. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.
    Mühlemann S; Truninger TC; Stawarczyk B; Hämmerle CH; Sailer I
    Clin Oral Implants Res; 2014 Jan; 25(1):74-81. PubMed ID: 23735182
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long-term study of hydroxylapatite implants in canine alveolar bone.
    Boyne PJ; Rothstein SS; Gumaer KI; Drobeck HP
    J Oral Maxillofac Surg; 1984 Sep; 42(9):589-94. PubMed ID: 6088739
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Surgical guides, off-axis reconstruction, and the use of custom abutments--Part I.
    Finley JM
    Dent Implantol Update; 1996 Feb; 7(2):9-12. PubMed ID: 9525162
    [No Abstract]   [Full Text] [Related]  

  • 26. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.
    Xia D; Lin H; Yuan S; Bai W; Zheng G
    Biomed Mater Eng; 2014; 24(6):2143-9. PubMed ID: 25226912
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Histologic observation of soft tissue responses to implanted, multifaceted particles and discs of hydroxylapatite.
    Drobeck HP; Rothstein SS; Gumaer KI; Sherer AD; Slighter RG
    J Oral Maxillofac Surg; 1984 Mar; 42(3):143-9. PubMed ID: 6321707
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An In Vitro Comparison of Fracture Load of Zirconia Custom Abutments with Internal Connection and Different Angulations and Thicknesses: Part II.
    Zandparsa R; Albosefi A
    J Prosthodont; 2016 Feb; 25(2):151-5. PubMed ID: 25865430
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Intraosseous dental implants: nature of the interface.
    Kent JN; De Long P; Homsy CA; Hinds EC
    J Am Dent Assoc; 1974 Nov; 89(5):1142-51. PubMed ID: 4610029
    [No Abstract]   [Full Text] [Related]  

  • 30. An in vitro comparison of fracture load of zirconia custom abutments with internal connection and different angulations and thickness: part I.
    Albosefi A; Finkelman M; Zandparsa R
    J Prosthodont; 2014 Jun; 23(4):296-301. PubMed ID: 24417713
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation.
    Truninger TC; Stawarczyk B; Leutert CR; Sailer TR; Hämmerle CH; Sailer I
    Clin Oral Implants Res; 2012 Jan; 23(1):12-8. PubMed ID: 21443610
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The effect of diameter and length of hydroxylapatite-coated dental implants on ultimate pullout force in dog alveolar bone.
    Block MS; Delgado A; Fontenot MG
    J Oral Maxillofac Surg; 1990 Feb; 48(2):174-8. PubMed ID: 2153788
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of superstructure geometry on the mechanical behavior of zirconia implant abutments: a finite element analysis.
    Geringer A; Diebels S; Nothdurft FP
    Biomed Tech (Berl); 2014 Dec; 59(6):501-6. PubMed ID: 25029078
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Molecular Assessment of Human Peri-implant Mucosal Healing at Laser-Modified and Machined Titanium Abutments.
    Leong A; De Kok I; Mendonça D; Cooper LF
    Int J Oral Maxillofac Implants; 2018; 33(4):895-904. PubMed ID: 30025007
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In vitro fatigue and fracture strength testing of one-piece zirconia implant abutments and zirconia implant abutments connected to titanium cores.
    Stimmelmayr M; Sagerer S; Erdelt K; Beuer F
    Int J Oral Maxillofac Implants; 2013; 28(2):488-93. PubMed ID: 23527351
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept.
    Sailer I; Asgeirsson AG; Thoma DS; Fehmer V; Aspelund T; Özcan M; Pjetursson BE
    Clin Oral Implants Res; 2018 Apr; 29(4):411-423. PubMed ID: 29527740
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Retentive strength of two-piece CAD/CAM zirconia implant abutments.
    Gehrke P; Alius J; Fischer C; Erdelt KJ; Beuer F
    Clin Implant Dent Relat Res; 2014 Dec; 16(6):920-5. PubMed ID: 23527950
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The shear strength between bone and porous ceramic root implants in the guinea pig incisor socket.
    Atkinson PJ; Seedhom BB; Roberts EW
    Biomaterials; 1985 Mar; 6(2):75-81. PubMed ID: 2988659
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vitro fatigue and fracture resistance of one- and two-piece CAD/CAM zirconia implant abutments.
    Gehrke P; Johannson D; Fischer C; Stawarczyk B; Beuer F
    Int J Oral Maxillofac Implants; 2015; 30(3):546-54. PubMed ID: 26009905
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Implants. Part two. Questions need answering.
    English CE
    CDA J; 1988 Jan; 16(1):26-34. PubMed ID: 2830033
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.