These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

77 related articles for article (PubMed ID: 2855520)

  • 1. [An experimental study on bone tissue response to a titanium alloy coated with hydroxyapatite].
    Fukuoka K; Hirai K; Kubo T; Ukai T; Esaka M; Kajiyama S; Wadamoto M; Maeda N; Satomi K; Hashimoto M
    Hiroshima Daigaku Shigaku Zasshi; 1988 Jun; 20(1):175-9. PubMed ID: 2855520
    [No Abstract]   [Full Text] [Related]  

  • 2. Differences between the bony interfaces of titanium and hydroxyapatite-alumina plasma-sprayed titanium blade implants.
    Morimoto K; Kihara A; Takeshita F; Akedo H; Suetsugu T
    J Oral Implantol; 1988; 14(3):314-24. PubMed ID: 2855931
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interface mechanics and histology of titanium and hydroxylapatite-coated titanium for dental implant applications.
    Cook SD; Kay JF; Thomas KA; Jarcho M
    Int J Oral Maxillofac Implants; 1987; 2(1):15-22. PubMed ID: 3032787
    [No Abstract]   [Full Text] [Related]  

  • 4. Comparison of tissue reaction and osteointegration of metal implants between hydroxyapatite/Ti alloy coat: an animal experimental study.
    Itiravivong P; Promasa A; Laiprasert T; Techapongworachai T; Kuptniratsaikul S; Thanakit V; Heimann RB
    J Med Assoc Thai; 2003 Jun; 86 Suppl 2():S422-31. PubMed ID: 12930020
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Early bone apposition in vivo on plasma-sprayed and electrochemically deposited hydroxyapatite coatings on titanium alloy.
    Wang H; Eliaz N; Xiang Z; Hsu HP; Spector M; Hobbs LW
    Biomaterials; 2006 Aug; 27(23):4192-203. PubMed ID: 16618502
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Histological and histomorphometrical evaluation of the bone reaction to three different titanium alloy and hydroxyapatite coated implants.
    Jansen JA; van der Waerden JP; Wolke JG
    J Appl Biomater; 1993; 4(3):213-9. PubMed ID: 10171978
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Hydroxylapatite-coated metallic implants: study of the bond strength and histology of the bone/implant contact zone].
    Thomas KA; Cook SD
    Phillip J Restaur Zahnmed; 1987 Oct; 4(5):287-301. PubMed ID: 2833784
    [No Abstract]   [Full Text] [Related]  

  • 8. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.
    Nimb L; Jensen JS; Gotfredsen K
    J Biomed Mater Res; 1995 Dec; 29(12):1477-82. PubMed ID: 8600137
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical failure of hydroxyapatite-coated titanium and cobalt-chromium-molybdenum alloy implants. An animal study.
    Nimb L; Gotfredsen K; Steen Jensen J
    Acta Orthop Belg; 1993; 59(4):333-8. PubMed ID: 8116363
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants.
    Hayashi K; Inadome T; Mashima T; Sugioka Y
    J Biomed Mater Res; 1993 May; 27(5):557-63. PubMed ID: 8314808
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bonding capacity in bone of HIP-processed HA-coated titanium: mechanical and histological investigations.
    Wie H; Herø H; Solheim T; Kleven E; Rørvik AM; Haanaes HR
    J Biomed Mater Res; 1995 Nov; 29(11):1443-9. PubMed ID: 8582913
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cyclic fatigue of hydroxyapatite-coated titanium alloy implant material--effect of crystallinity.
    Ashroff S; Napper SA; Hale PN; Siriwardane U; Mukherjee DP
    J Long Term Eff Med Implants; 1996; 6(3-4):143-55. PubMed ID: 10167358
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implant surface alterations from a nonmetallic ultrasonic tip.
    Bailey GM; Gardner JS; Day MH; Kovanda BJ
    J West Soc Periodontol Periodontal Abstr; 1998; 46(3):69-73. PubMed ID: 10597152
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An experimental study on the tissue compatibility of the titanium blade-vent implant coated with HAP-alumina in the semi-functional state.
    Morimoto K; Kihara A; Takeshita F; Suetsugu T; Tanaka J; Tsunosue U
    J Oral Implantol; 1987; 13(3):387-401. PubMed ID: 2855647
    [No Abstract]   [Full Text] [Related]  

  • 15. Tissue response to implanted ceramic-coated titanium alloys in rats.
    Satomi K; Akagawa Y; Nikai H; Tsuru H
    J Oral Rehabil; 1988 Jul; 15(4):339-45. PubMed ID: 3171755
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mixed mode fracture characterization of hydroxylapatite-titanium alloy interface.
    Mann KA; Edidin AA; Kinoshita RK; Manley MT
    J Appl Biomater; 1994; 5(4):285-91. PubMed ID: 8580535
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enhanced bone bonding of hydroxyapatite-coated titanium implants by electrical polarization.
    Kobayashi T; Itoh S; Nakamura S; Nakamura M; Shinomiya K; Yamashita K
    J Biomed Mater Res A; 2007 Jul; 82(1):145-51. PubMed ID: 17269143
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone.
    Johansson CB; Han CH; Wennerberg A; Albrektsson T
    Int J Oral Maxillofac Implants; 1998; 13(3):315-21. PubMed ID: 9638001
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bone response to titanium alloy implants placed in diabetic rats.
    McCracken M; Lemons JE; Rahemtulla F; Prince CW; Feldman D
    Int J Oral Maxillofac Implants; 2000; 15(3):345-54. PubMed ID: 10874799
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials.
    Thomas KA; Kay JF; Cook SD; Jarcho M
    J Biomed Mater Res; 1987 Dec; 21(12):1395-414. PubMed ID: 3429474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.