These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
238 related articles for article (PubMed ID: 28567612)
1. Uncontrolled delivery of liquid volatile anaesthetic when using the anaesthetic conserving device. Karnjuš I; Mekiš D; Križmarić M J Clin Monit Comput; 2018 Aug; 32(4):629-638. PubMed ID: 28567612 [TBL] [Abstract][Full Text] [Related]
2. [Functioning of the anaesthetic conserving device: aspects to consider for use in inhalational sedation]. Meiser A; Bellgardt M; Vogelsang H; Sirtl C; Weber T Anaesthesist; 2010 Nov; 59(11):1029-40. PubMed ID: 20878139 [TBL] [Abstract][Full Text] [Related]
3. A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care. Farrell R; Oomen G; Carey P J Clin Monit Comput; 2018 Aug; 32(4):595-604. PubMed ID: 29388094 [TBL] [Abstract][Full Text] [Related]
4. Efficient application of volatile anaesthetics: total rebreathing or specific reflection? Bomberg H; Volk T; Groesdonk HV; Meiser A J Clin Monit Comput; 2018 Aug; 32(4):615-622. PubMed ID: 29302897 [TBL] [Abstract][Full Text] [Related]
5. Laboratory evaluation of a novel anaesthesia delivery device. Paul A; Clark JN; Salama IE; Jenkins BJ; Goodwin N; Wilkes AR; Mahoney PF; Hall JE Anaesthesia; 2017 Jan; 72(1):63-72. PubMed ID: 27785790 [TBL] [Abstract][Full Text] [Related]
6. [Sedation concepts with volatile anaesthetics in intensive care: practical use and current experiences with the AnaConDa system]. Kompardt J; Schärff K; Kubosch K; Pohl C; Bomplitz M; Soukup J Anaesthesist; 2008 Dec; 57(12):1201-9. PubMed ID: 18839123 [TBL] [Abstract][Full Text] [Related]
7. Inhaled anesthetic agent sedation in the ICU and trace gas concentrations: a review. Herzog-Niescery J; Seipp HM; Weber TP; Bellgardt M J Clin Monit Comput; 2018 Aug; 32(4):667-675. PubMed ID: 28861655 [TBL] [Abstract][Full Text] [Related]
8. Increasing the reflection efficiency of the Sedaconda ACD-S by heating and cooling the anaesthetic reflector: a bench study using a test lung. Meiser A; Meis PLF; O'Gara B; Volk T; Kermad A J Clin Monit Comput; 2023 Jun; 37(3):919-924. PubMed ID: 36625981 [TBL] [Abstract][Full Text] [Related]
9. Health worker exposure risk during inhalation sedation with sevoflurane using the (AnaConDa®) anaesthetic conserving device. González-Rodríguez R; Muñoz Martínez A; Galan Serrano J; Moral García MV Rev Esp Anestesiol Reanim; 2014 Mar; 61(3):133-9. PubMed ID: 24439525 [TBL] [Abstract][Full Text] [Related]
10. Comparing charcoal and zeolite reflection filters for volatile anaesthetics: A laboratory evaluation. Sturesson LW; Frennström JO; Ilardi M; Reinstrup P Eur J Anaesthesiol; 2015 Aug; 32(8):521-6. PubMed ID: 25387299 [TBL] [Abstract][Full Text] [Related]
11. Technical performance and reflection capacity of the anaesthetic conserving device--a bench study with isoflurane and sevoflurane. Meiser A; Bellgardt M; Belda J; Röhm K; Laubenthal H; Sirtl C J Clin Monit Comput; 2009 Feb; 23(1):11-9. PubMed ID: 19189222 [TBL] [Abstract][Full Text] [Related]
12. Environmental safety: Air pollution while using MIRUS™ for short-term sedation in the ICU. Herzog-Niescery J; Vogelsang H; Gude P; Seipp HM; Uhl W; Weber TP; Bellgardt M Acta Anaesthesiol Scand; 2019 Jan; 63(1):86-92. PubMed ID: 30088264 [TBL] [Abstract][Full Text] [Related]
13. Wash-in kinetics for sevoflurane using a disposable delivery system (AnaConDa) in cardiac surgery patients. Sturesson LW; Johansson A; Bodelsson M; Malmkvist G Br J Anaesth; 2009 Apr; 102(4):470-6. PubMed ID: 19244261 [TBL] [Abstract][Full Text] [Related]
14. Ambient isoflurane pollution and isoflurane consumption during intensive care unit sedation with the Anesthetic Conserving Device. Sackey PV; Martling CR; Nise G; Radell PJ Crit Care Med; 2005 Mar; 33(3):585-90. PubMed ID: 15753751 [TBL] [Abstract][Full Text] [Related]
15. Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model. Bomberg H; Meiser F; Daume P; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A Anesth Analg; 2019 Aug; 129(2):371-379. PubMed ID: 29787413 [TBL] [Abstract][Full Text] [Related]
17. Use of the MIRUS™ system for general anaesthesia during surgery: a comparison of isoflurane, sevoflurane and desflurane. Bellgardt M; Drees D; Vinnikov V; Procopiuc L; Meiser A; Bomberg H; Gude P; Vogelsang H; Weber TP; Herzog-Niescery J J Clin Monit Comput; 2018 Aug; 32(4):623-627. PubMed ID: 29633099 [TBL] [Abstract][Full Text] [Related]
18. Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilation. Sturesson LW; Bodelsson M; Jonson B; Malmkvist G Br J Anaesth; 2014 Sep; 113(3):508-14. PubMed ID: 24871871 [TBL] [Abstract][Full Text] [Related]
19. Halving the volume of AnaConDa: initial clinical experience with a new small-volume anaesthetic reflector in critically ill patients-a quality improvement project. Bomberg H; Meiser F; Zimmer S; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A J Clin Monit Comput; 2018 Aug; 32(4):639-646. PubMed ID: 29700664 [TBL] [Abstract][Full Text] [Related]
20. AnaConDa reflection filter: bench and patient evaluation of safety and volatile anesthetic conservation. Berton J; Sargentini C; Nguyen JL; Belii A; Beydon L Anesth Analg; 2007 Jan; 104(1):130-4. PubMed ID: 17179257 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]