These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

500 related articles for article (PubMed ID: 28569391)

  • 1. Permanent His bundle pacing: Electrophysiological and echocardiographic observations from long-term follow-up.
    Vijayaraman P; Dandamudi G; Lustgarten D; Ellenbogen KA
    Pacing Clin Electrophysiol; 2017 Jul; 40(7):883-891. PubMed ID: 28569391
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Permanent His-bundle pacing for cardiac resynchronization therapy: Initial feasibility study in lieu of left ventricular lead.
    Ajijola OA; Upadhyay GA; Macias C; Shivkumar K; Tung R
    Heart Rhythm; 2017 Sep; 14(9):1353-1361. PubMed ID: 28400315
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Atrioventricular node ablation and His bundle pacing.
    Vijayaraman P; Subzposh FA; Naperkowski A
    Europace; 2017 Dec; 19(suppl_4):iv10-iv16. PubMed ID: 29220422
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Permanent His-bundle pacing in patients with prosthetic cardiac valves.
    Sharma PS; Subzposh FA; Ellenbogen KA; Vijayaraman P
    Heart Rhythm; 2017 Jan; 14(1):59-64. PubMed ID: 27663607
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Permanent His-bundle pacing: Long-term lead performance and clinical outcomes.
    Vijayaraman P; Naperkowski A; Subzposh FA; Abdelrahman M; Sharma PS; Oren JW; Dandamudi G; Ellenbogen KA
    Heart Rhythm; 2018 May; 15(5):696-702. PubMed ID: 29274474
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Permanent His-bundle pacing maintains long-term ventricular synchrony and left ventricular performance, unlike conventional right ventricular apical pacing.
    Catanzariti D; Maines M; Manica A; Angheben C; Varbaro A; Vergara G
    Europace; 2013 Apr; 15(4):546-53. PubMed ID: 22997222
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block.
    Huang W; Su L; Wu S; Xu L; Xiao F; Zhou X; Mao G; Vijayaraman P; Ellenbogen KA
    Heart; 2019 Jan; 105(2):137-143. PubMed ID: 30093543
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Permanent His Bundle Pacing for Cardiac Resynchronization Therapy in Patients With Heart Failure and Right Bundle Branch Block.
    Sharma PS; Naperkowski A; Bauch TD; Chan JYS; Arnold AD; Whinnett ZI; Ellenbogen KA; Vijayaraman P
    Circ Arrhythm Electrophysiol; 2018 Sep; 11(9):e006613. PubMed ID: 30354292
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel Method for Assessment of His Bundle Pacing Morphology Using Near Field and Far Field Device Electrograms.
    Saini A; Serafini NJ; Campbell S; Waugh WB; Zimberg R; Sheldon TJ; Kron J; Kalahasty G; Padala SK; Trohman R; Shepard RK; Koneru JN; Vijayaraman P; Ellenbogen KA; Sharma PS
    Circ Arrhythm Electrophysiol; 2019 Feb; 12(2):e006878. PubMed ID: 30707036
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing.
    Vijayaraman P; Subzposh FA; Naperkowski A; Panikkath R; John K; Mascarenhas V; Bauch TD; Huang W
    Heart Rhythm; 2019 Dec; 16(12):1774-1782. PubMed ID: 31136869
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outcomes of His-bundle pacing upgrade after long-term right ventricular pacing and/or pacing-induced cardiomyopathy: Insights into disease progression.
    Vijayaraman P; Herweg B; Dandamudi G; Mittal S; Bhatt AG; Marcantoni L; Naperkowski A; Sharma PS; Zanon F
    Heart Rhythm; 2019 Oct; 16(10):1554-1561. PubMed ID: 30930330
    [TBL] [Abstract][Full Text] [Related]  

  • 12. His bundle pacing-is it the final frontier of physiological pacing ?-A single centre experience from the Indian sub-Continent.
    Prakash VS; Hegde AV; Nagamalesh UM; Ramkumar S; Sai Krishna Y; Prakash VR; Potluri AR
    Indian Heart J; 2020; 72(3):160-165. PubMed ID: 32768014
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Permanent His-bundle pacing as an alternative to biventricular pacing for cardiac resynchronization therapy: A multicenter experience.
    Sharma PS; Dandamudi G; Herweg B; Wilson D; Singh R; Naperkowski A; Koneru JN; Ellenbogen KA; Vijayaraman P
    Heart Rhythm; 2018 Mar; 15(3):413-420. PubMed ID: 29031929
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice.
    Sharma PS; Dandamudi G; Naperkowski A; Oren JW; Storm RH; Ellenbogen KA; Vijayaraman P
    Heart Rhythm; 2015 Feb; 12(2):305-12. PubMed ID: 25446158
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Permanent His-bundle pacing: seeking physiological ventricular pacing.
    Barba-Pichardo R; Moriña-Vázquez P; Fernández-Gómez JM; Venegas-Gamero J; Herrera-Carranza M
    Europace; 2010 Apr; 12(4):527-33. PubMed ID: 20338988
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Upgrade to his bundle pacing in pacing-dependent patients referred for pulse generator change: Feasibility and intermediate term follow up.
    Ye Y; Zhang Z; Sheng X; Wang B; Chen S; Pan Y; Lan J; Sun Y; Luan Y; Jiang C; Fu G
    Int J Cardiol; 2018 Jun; 260():88-92. PubMed ID: 29622459
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intermediate-term performance and safety of His-bundle pacing leads: A single-center experience.
    Teigeler T; Kolominsky J; Vo C; Shepard RK; Kalahasty G; Kron J; Huizar JF; Kaszala K; Tan AY; Koneru JN; Ellenbogen KA; Padala SK
    Heart Rhythm; 2021 May; 18(5):743-749. PubMed ID: 33418127
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Feasibility of His-bundle pacing in patients with conduction disorders following transcatheter aortic valve replacement.
    De Pooter J; Gauthey A; Calle S; Noel A; Kefer J; Marchandise S; Coeman M; Philipsen T; Kayaert P; Gheeraert P; Jordaens L; Timmermans F; Van Heuverswyn F; Bordachar P; le Polain de Waroux JB
    J Cardiovasc Electrophysiol; 2020 Apr; 31(4):813-821. PubMed ID: 31990128
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acute His-Bundle Injury Current during Permanent His-Bundle Pacing Predicts Excellent Pacing Outcomes.
    Vijayaraman P; Dandamudi G; Worsnick S; Ellenbogen KA
    Pacing Clin Electrophysiol; 2015 May; 38(5):540-6. PubMed ID: 25588497
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Beneficial effects of upgrading to His bundle pacing in chronically paced patients with left ventricular ejection fraction <50.
    Shan P; Su L; Zhou X; Wu S; Xu L; Xiao F; Zhou X; Ellenbogen KA; Huang W
    Heart Rhythm; 2018 Mar; 15(3):405-412. PubMed ID: 29081396
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.