152 related articles for article (PubMed ID: 2857276)
1. An evaluation of the efficiency of face masks in the resuscitation of newborn infants.
Palme C; Nyström B; Tunell R
Lancet; 1985 Jan; 1(8422):207-10. PubMed ID: 2857276
[TBL] [Abstract][Full Text] [Related]
2. Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.
O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F392-6. PubMed ID: 15871989
[TBL] [Abstract][Full Text] [Related]
3. Airway obstruction during mask ventilation of very low birth weight infants during neonatal resuscitation.
Finer NN; Rich W; Wang C; Leone T
Pediatrics; 2009 Mar; 123(3):865-9. PubMed ID: 19255015
[TBL] [Abstract][Full Text] [Related]
4. [The Laerdal mask is much better than the Rendell-Baker Soucek mask for the resuscitation of children].
Yamashita M; Motokawa K
Masui; 1986 Oct; 35(10):1547-9. PubMed ID: 3806945
[No Abstract] [Full Text] [Related]
5. A respiratory function monitor improves mask ventilation.
Wood FE; Morley CJ; Dawson JA; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2008 Sep; 93(5):F380-1. PubMed ID: 18192329
[TBL] [Abstract][Full Text] [Related]
6. Neonatal resuscitation 3: manometer use in a model of face mask ventilation.
O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F397-400. PubMed ID: 15871988
[TBL] [Abstract][Full Text] [Related]
7. Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.
Cheung D; Mian Q; Cheung PY; O'Reilly M; Aziz K; van Os S; Pichler G; Schmölzer GM
J Perinatol; 2015 Jul; 35(7):464-8. PubMed ID: 25719544
[TBL] [Abstract][Full Text] [Related]
8. Neonatal resuscitation 1: a model to measure inspired and expired tidal volumes and assess leakage at the face mask.
O'Donnell CP; Kamlin CO; Davis PG; Morley CJ
Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F388-91. PubMed ID: 15871990
[TBL] [Abstract][Full Text] [Related]
9. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes.
Rafferty AR; Johnson L; Davis PG; Dawson JA; Thio M; Owen LS
Arch Dis Child Fetal Neonatal Ed; 2018 Nov; 103(6):F562-F566. PubMed ID: 29191811
[TBL] [Abstract][Full Text] [Related]
10. Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial.
Trevisanuto D; Cavallin F; Nguyen LN; Nguyen TV; Tran LD; Tran CD; Doglioni N; Micaglio M; Moccia L
J Pediatr; 2015 Aug; 167(2):286-91.e1. PubMed ID: 26003882
[TBL] [Abstract][Full Text] [Related]
11. Assessment of mouth-to-mask ventilation in resuscitation of asphyxic newborn babies. A pilot study.
Massawe A; Kilewo C; Irani S; Verma RJ; Chakrapam AB; Ribbe T; Tunell R; Fischler B
Trop Med Int Health; 1996 Dec; 1(6):865-73. PubMed ID: 8980603
[TBL] [Abstract][Full Text] [Related]
12. Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.
Deindl P; O'Reilly M; Zoller K; Berger A; Pollak A; Schwindt J; Schmölzer GM
Eur J Pediatr; 2014 Jan; 173(1):75-9. PubMed ID: 23933670
[TBL] [Abstract][Full Text] [Related]
13. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?
Tracy MB; Priyadarshi A; Goel D; Lowe K; Huvanandana J; Hinder M
Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F271-F276. PubMed ID: 28802261
[TBL] [Abstract][Full Text] [Related]
14. Assessing the effectiveness of two round neonatal resuscitation masks: study 1.
Wood FE; Morley CJ; Dawson JA; Kamlin CO; Owen LS; Donath S; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2008 May; 93(3):F235-7. PubMed ID: 18039749
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of mouth-to-mask ventilation devices.
Hess D; Ness C; Oppel A; Rhoads K
Respir Care; 1989 Mar; 34(3):191-5. PubMed ID: 10315772
[TBL] [Abstract][Full Text] [Related]
16. Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2.
Wood FE; Morley CJ; Dawson JA; Kamlin CO; Owen LS; Donath S; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2008 May; 93(3):F230-4. PubMed ID: 18039750
[TBL] [Abstract][Full Text] [Related]
17. Initial stabilisation of preterm infants: a new resuscitation system with low imposed work of breathing for use with face mask or nasal prongs.
Donaldsson S; Drevhammar T; Taittonen L; Klemming S; Jonsson B
Arch Dis Child Fetal Neonatal Ed; 2017 May; 102(3):F203-F207. PubMed ID: 27553588
[TBL] [Abstract][Full Text] [Related]
18. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.
Lorenz L; Maxfield DA; Dawson JA; Kamlin CO; McGrory L; Thio M; Donath SM; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2016 Sep; 101(5):F464-7. PubMed ID: 26847369
[TBL] [Abstract][Full Text] [Related]
19. Measurements from preterm infants to guide face mask size.
O'Shea JE; Thio M; Owen LS; Wong C; Dawson JA; Davis PG
Arch Dis Child Fetal Neonatal Ed; 2016 Jul; 101(4):F294-8. PubMed ID: 25862726
[TBL] [Abstract][Full Text] [Related]
20. Delivery room resuscitation of near-term infants: role of the laryngeal mask airway.
Zanardo V; Weiner G; Micaglio M; Doglioni N; Buzzacchero R; Trevisanuto D
Resuscitation; 2010 Mar; 81(3):327-30. PubMed ID: 20022416
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]