BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

346 related articles for article (PubMed ID: 28573341)

  • 1. Identification of Methicillin-Resistant Staphylococcus aureus (MRSA) Using Simultaneous Detection of mecA, nuc, and femB by Loop-Mediated Isothermal Amplification (LAMP).
    Chen C; Zhao Q; Guo J; Li Y; Chen Q
    Curr Microbiol; 2017 Aug; 74(8):965-971. PubMed ID: 28573341
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rapid detection of Staphylococcus aureus by loop-mediated isothermal amplification.
    Wang XR; Wu LF; Wang Y; Ma YY; Chen FH; Ou HL
    Appl Biochem Biotechnol; 2015 Jan; 175(2):882-91. PubMed ID: 25349088
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemoculture and Direct Sputum Detection of mecA-Mediated Methicillin-Resistant Staphylococcus aureus by Loop-Mediated Isothermal Amplification in Combination With a Lateral-Flow Dipstick.
    Nawattanapaiboon K; Prombun P; Santanirand P; Vongsakulyanon A; Srikhirin T; Sutapun B; Kiatpathomchai W
    J Clin Lab Anal; 2016 Sep; 30(5):760-7. PubMed ID: 26991017
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct bacterial loop-mediated isothermal amplification detection on the pathogenic features of the nosocomial pathogen - Methicillin resistant Staphylococcus aureus strains with respiratory origins.
    Lin Q; Xu P; Li J; Chen Y; Feng J
    Microb Pathog; 2017 Aug; 109():183-188. PubMed ID: 28578093
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The rapid and visual detection of methicillin-susceptible and methicillin-resistant Staphylococcus aureus using multiplex loop-mediated isothermal amplification linked to a nanoparticle-based lateral flow biosensor.
    Chen X; Ma K; Yi X; Xiong L; Wang Y; Li S
    Antimicrob Resist Infect Control; 2020 Jul; 9(1):111. PubMed ID: 32680560
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid detection of mecA and spa by the loop-mediated isothermal amplification (LAMP) method.
    Koide Y; Maeda H; Yamabe K; Naruishi K; Yamamoto T; Kokeguchi S; Takashiba S
    Lett Appl Microbiol; 2010 Apr; 50(4):386-92. PubMed ID: 20149082
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accurate Detection of Methicillin-Resistant Staphylococcus aureus in Mixtures by Use of Single-Bacterium Duplex Droplet Digital PCR.
    Luo J; Li J; Yang H; Yu J; Wei H
    J Clin Microbiol; 2017 Oct; 55(10):2946-2955. PubMed ID: 28724560
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and application of a triplex-PCR assay for rapid detection of methicillin-resistant Staphylococcus aureus from pigs.
    Rajkhowa S; Pegu SR; Patil GP; Agrawal RK
    Lett Appl Microbiol; 2021 Feb; 72(2):121-125. PubMed ID: 33090539
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Loop-mediated isothermal amplification assays for identification of antiseptic- and methicillin-resistant Staphylococcus aureus.
    Hanaki K; Sekiguchi J; Shimada K; Sato A; Watari H; Kojima T; Miyoshi-Akiyama T; Kirikae T
    J Microbiol Methods; 2011 Feb; 84(2):251-4. PubMed ID: 21167878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous Dual-Gene Test of Methicillin-Resistant Staphylococcus Aureus using an Argonaute-Centered Portable and Visual Biosensor.
    Kou J; Li Y; Zhao Z; Qiao J; Zhang Q; Han X; Cheng X; Man S; Ma L
    Small; 2024 Jun; 20(24):e2311764. PubMed ID: 38506607
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multiplex real-time PCR assay for rapid detection of methicillin-resistant staphylococci directly from positive blood cultures.
    Wang HY; Kim S; Kim J; Park SD; Uh Y; Lee H
    J Clin Microbiol; 2014 Jun; 52(6):1911-20. PubMed ID: 24648566
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Identification of methicillin-resistant Staphylococcus aureus (MRSA) strains isolated from burn patients by multiplex PCR.
    Montazeri EA; Khosravi AD; Jolodar A; Ghaderpanah M; Azarpira S
    Burns; 2015 May; 41(3):590-4. PubMed ID: 25441547
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cas12a/Guide RNA-Based Platforms for Rapidly and Accurately Identifying Staphylococcus aureus and Methicillin-Resistant S. aureus.
    Cao X; Chang Y; Tao C; Chen S; Lin Q; Ling C; Huang S; Zhang H
    Microbiol Spectr; 2023 Mar; 11(2):e0487022. PubMed ID: 36943040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A selective broth enrichment combined with real-time nuc-mecA-PCR in the exclusion of MRSA.
    Pasanen T; Korkeila M; Mero S; Tarkka E; Piiparinen H; Vuopio-Varkila J; Vaara M; Tissari P
    APMIS; 2010 Jan; 118(1):74-80. PubMed ID: 20041874
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of loop-mediated isothermal amplification technique to rapid and direct detection of methicillin-resistant Staphylococcus aureus (MRSA) in blood cultures.
    Misawa Y; Yoshida A; Saito R; Yoshida H; Okuzumi K; Ito N; Okada M; Moriya K; Koike K
    J Infect Chemother; 2007 Jun; 13(3):134-40. PubMed ID: 17593498
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rapid visualization and detection of Staphylococcus aureus based on loop-mediated isothermal amplification.
    Wu C; Zeng Y; He Y
    World J Microbiol Biotechnol; 2021 Nov; 37(12):209. PubMed ID: 34719733
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of LAMP Assay Using Phenotypic Tests and Conventional PCR for Detection of nuc and mecA genes Among Clinical Isolates of Staphylococcus spp.
    Sudhaharan S; Vanjari L; Mamidi N; Ede N; Vemu L
    J Clin Diagn Res; 2015 Aug; 9(8):DC06-9. PubMed ID: 26435941
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel extraction-free dual HiFi-LAMP assay for detection of methicillin-sensitive and methicillin-resistant
    Zhao X; Zeng Y; Yan B; Liu Y; Qian Y; Zhu A; Zhao Y; Zhang X; Zhang C; Wan Z
    Microbiol Spectr; 2024 Apr; 12(4):e0413323. PubMed ID: 38376361
    [No Abstract]   [Full Text] [Related]  

  • 19. Triplex real-time polymerase chain reaction assay for simultaneous detection of Staphylococcus aureus and coagulase-negative staphylococci and determination of methicillin resistance directly from positive blood culture bottles.
    Kilic A; Muldrew KL; Tang YW; Basustaoglu AC
    Diagn Microbiol Infect Dis; 2010 Apr; 66(4):349-55. PubMed ID: 20226325
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Feasibility of Loop-Mediated Isothermal Amplification for Rapid Detection of Methicillin-Susceptible and Methicillin-Resistant
    Kim SG; Choi GW; Choi WS; Lim CS; Jang WS; Bae JH
    Clin Orthop Surg; 2022 Sep; 14(3):466-473. PubMed ID: 36061848
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]