These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. The effect of variable arterial transducer level on the accuracy of pulse contour waveform-derived measurements in critically ill patients. He HW; Liu DW; Long Y; Wang XT; Zhao ML; Lai XL J Clin Monit Comput; 2016 Oct; 30(5):569-75. PubMed ID: 26298710 [TBL] [Abstract][Full Text] [Related]
4. Cardiac output and stroke volume variation measured by the pulse wave transit time method: a comparison with an arterial pressure-based cardiac output system. Suzuki T; Suzuki Y; Okuda J; Minoshima R; Misonoo Y; Ueda T; Kato J; Nagata H; Yamada T; Morisaki H J Clin Monit Comput; 2019 Jun; 33(3):385-392. PubMed ID: 29948667 [TBL] [Abstract][Full Text] [Related]
6. Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output. Jonas MM; Tanser SJ Curr Opin Crit Care; 2002 Jun; 8(3):257-61. PubMed ID: 12386506 [TBL] [Abstract][Full Text] [Related]
7. Comparison of the ability of two continuous cardiac output monitors to measure trends in cardiac output: estimated continuous cardiac output measured by modified pulse wave transit time and an arterial pulse contour-based cardiac output device. Terada T; Oiwa A; Maemura Y; Robert S; Kessoku S; Ochiai R J Clin Monit Comput; 2016 Oct; 30(5):621-7. PubMed ID: 26370094 [TBL] [Abstract][Full Text] [Related]
8. Can Currently Available Non-invasive Continuous Blood Pressure Monitors Replace Invasive Measurement With an Arterial Catheter? Gore P; Liu H; Bohringer C Cureus; 2024 Feb; 16(2):e54707. PubMed ID: 38529464 [TBL] [Abstract][Full Text] [Related]
9. [Experts consensus on the management of the right heart function in critically ill patients]. Wang XT; Liu DW; Zhang HM; Long Y; Guan XD; Qiu HB; Yu KJ; Yan J; Zhao H; Tang YQ; Ding X; Ma XC; Du W; Kang Y; Tang B; Ai YH; He HW; Chen DC; Chen H; Chai WZ; Zhou X; Cui N; Wang H; Rui X; Hu ZJ; Li JG; Xu Y; Yang Y; Ouyan B; Lin HY; Li YM; Wan XY; Yang RL; Qin YZ; Chao YG; Xie ZY; Sun RH; He ZY; Wang DF; Huang QQ; Jiang DP; Cao XY; Yu RG; Wang X; Chen XK; Wu JF; Zhang LN; Yin MG; Liu LX; Li SW; Chen ZJ; Luo Z; Zhonghua Nei Ke Za Zhi; 2017 Dec; 56(12):962-973. PubMed ID: 29202543 [TBL] [Abstract][Full Text] [Related]
10. Effective evaluation of arterial pulse waveform analysis by two-dimensional stroke volume variation-stroke volume index plots. Sawa T; Kinoshita M; Kainuma A; Akiyama K; Naito Y; Kato H; Amaya F; Shigemi K J Clin Monit Comput; 2017 Oct; 31(5):927-941. PubMed ID: 27492429 [TBL] [Abstract][Full Text] [Related]
11. [A Chinese consensus statement on the clinical application of transesophageal echocardiography for critical care (2019)]. Yin WH; Wang XT; Liu DW; Kang Y; Chao YG; Zhang LN; Zhang HM; Wu J; Liu LX; Zhu R; He W; ; Zhonghua Nei Ke Za Zhi; 2019 Dec; 58(12):869-882. PubMed ID: 31775449 [TBL] [Abstract][Full Text] [Related]
12. Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis. Lu Z; Mukkamala R J Appl Physiol (1985); 2006 Aug; 101(2):598-608. PubMed ID: 16849813 [TBL] [Abstract][Full Text] [Related]
13. Cardiac output estimated from an uncalibrated radial blood pressure waveform: validation in an Bikia V; Rovas G; Stergiopulos N Front Bioeng Biotechnol; 2023; 11():1199726. PubMed ID: 37324429 [No Abstract] [Full Text] [Related]
14. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Mercado P; Maizel J; Beyls C; Titeca-Beauport D; Joris M; Kontar L; Riviere A; Bonef O; Soupison T; Tribouilloy C; de Cagny B; Slama M Crit Care; 2017 Jun; 21(1):136. PubMed ID: 28595621 [TBL] [Abstract][Full Text] [Related]
15. Simultaneous comparison of thoracic bioimpedance and arterial pulse waveform-derived cardiac output with thermodilution measurement. Hirschl MM; Kittler H; Woisetschläger C; Siostrzonek P; Staudinger T; Kofler J; Oschatz E; Bur A; Gwechenberger M; Laggner AN Crit Care Med; 2000 Jun; 28(6):1798-802. PubMed ID: 10890622 [TBL] [Abstract][Full Text] [Related]
16. Continuous and minimally invasive cardiac output monitoring by long time interval analysis of a radial arterial pressure waveform: assessment using a large, public intensive care unit patient database. Zhang G; Mukkamala R Br J Anaesth; 2012 Sep; 109(3):339-44. PubMed ID: 22499767 [TBL] [Abstract][Full Text] [Related]
17. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery. Lu JK; Zhu C; Jing H; Wang YJ; Qing EM Chin Med J (Engl); 2012 Jun; 125(12):2099-103. PubMed ID: 22884136 [TBL] [Abstract][Full Text] [Related]