These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 28581943)

  • 1. Technical Considerations and Practical Guidance for Intracoronary Optical Coherence Tomography.
    Katwal AB; Lopez JJ
    Interv Cardiol Clin; 2015 Jul; 4(3):239-249. PubMed ID: 28581943
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Techniques and best practices for optical coherence tomography: a practical manual for interventional cardiologists.
    Lopez JJ; Arain SA; Madder R; Parekh N; Shroff AR; Westerhausen D
    Catheter Cardiovasc Interv; 2014 Nov; 84(5):687-99. PubMed ID: 24677364
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intravascular Ultrasound Versus Optical Coherence Tomography for Coronary Artery Imaging - Apples and Oranges?
    Rathod KS; Hamshere SM; Jones DA; Mathur A
    Interv Cardiol; 2015 Mar; 10(1):8-15. PubMed ID: 29588667
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Review of the ability of optical coherence tomography to characterize plaque, including a comparison with intravascular ultrasound.
    Patel NA; Stamper DL; Brezinski ME
    Cardiovasc Intervent Radiol; 2005; 28(1):1-9. PubMed ID: 15772720
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intracoronary optical coherence tomography for the assessment of in-stent restenosis.
    Rayoo R; Tuer Z; Sharma N; Barlis P
    Heart Lung Circ; 2011 May; 20(5):332-5. PubMed ID: 21185781
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention).
    Maehara A; Ben-Yehuda O; Ali Z; Wijns W; Bezerra HG; Shite J; Généreux P; Nichols M; Jenkins P; Witzenbichler B; Mintz GS; Stone GW
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1704-14. PubMed ID: 26585621
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of optical coherence tomography in acute coronary syndrome.
    Matsuo Y; Kubo T; Akasaka T
    Expert Rev Cardiovasc Ther; 2016; 14(5):649-57. PubMed ID: 26795131
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frequency-domain optical coherence tomography assessment of unprotected left main coronary artery disease-a comparison with intravascular ultrasound.
    Fujino Y; Bezerra HG; Attizzani GF; Wang W; Yamamoto H; Chamié D; Kanaya T; Mehanna E; Tahara S; Nakamura S; Costa MA
    Catheter Cardiovasc Interv; 2013 Sep; 82(3):E173-83. PubMed ID: 23359350
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Percutaneous Coronary Intervention Planning and Optimization with Optical Coherence Tomography.
    Bernelli C; Sirbu V; Guagliumi G
    Interv Cardiol Clin; 2015 Jul; 4(3):251-284. PubMed ID: 28581944
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of intravascular ultrasound and optical coherence tomography in identifying functionally significant coronary stenosis according to vessel diameter: A meta-analysis of 2,581 patients and 2,807 lesions.
    D'Ascenzo F; Barbero U; Cerrato E; Lipinski MJ; Omedè P; Montefusco A; Taha S; Naganuma T; Reith S; Voros S; Latib A; Gonzalo N; Quadri G; Colombo A; Biondi-Zoccai G; Escaned J; Moretti C; Gaita F
    Am Heart J; 2015 May; 169(5):663-73. PubMed ID: 25965714
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hybrid intravascular ultrasound and optical coherence tomography catheter for imaging of coronary atherosclerosis.
    Li BH; Leung AS; Soong A; Munding CE; Lee H; Thind AS; Munce NR; Wright GA; Rowsell CH; Yang VX; Strauss BH; Foster FS; Courtney BK
    Catheter Cardiovasc Interv; 2013 Feb; 81(3):494-507. PubMed ID: 22566368
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Utility of optical coherence tomography and intravascular ultrasound for the evaluation of coronary lesions.
    Girassolli A; Carrizo S; Jiménez-Valero S; Sánchez Recalde A; Ruiz García J; Galeotte G; Moreno R
    Rev Port Cardiol; 2013 Nov; 32(11):925-9. PubMed ID: 24268869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optical Coherence Tomography in the Diagnosis and Management of Spontaneous Coronary Artery Dissection.
    Franco C; Eng L; Saw J
    Interv Cardiol Clin; 2015 Jul; 4(3):309-320. PubMed ID: 28581947
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optical coherence tomography imaging: current status and future perspectives : Current and future developments in OCT.
    Kubo T; Akasaka T
    Cardiovasc Interv Ther; 2010 Jan; 25(1):2-10. PubMed ID: 24122426
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Co-registration of optical coherence tomography and X-ray angiography in percutaneous coronary intervention. the Does Optical Coherence Tomography Optimize Revascularization (DOCTOR) fusion study.
    Hebsgaard L; Nielsen TM; Tu S; Krusell LR; Maeng M; Veien KT; Raungaard B; Terkelsen CJ; Kaltoft A; Reiber JH; Lassen JF; Christiansen EH; Holm NR
    Int J Cardiol; 2015 Mar; 182():272-8. PubMed ID: 25585362
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Real-time optical coherence tomography for minimally invasive imaging of prostate ablation.
    Boppart SA; Herrmann JM; Pitris C; Stamper DL; Brezinski ME; Fujimoto JG
    Comput Aided Surg; 2001; 6(2):94-103. PubMed ID: 11568985
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intracoronary optical coherence tomography: a review of clinical applications.
    Zivelonghi C; Ghione M; Kilickesmez K; Loureiro RE; Foin N; Lindsay A; de Silva R; Ribichini F; Vassanelli C; Di Mario C
    J Cardiovasc Med (Hagerstown); 2014 Jul; 15(7):543-53. PubMed ID: 24922045
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy.
    Kubo T; Imanishi T; Takarada S; Kuroi A; Ueno S; Yamano T; Tanimoto T; Matsuo Y; Masho T; Kitabata H; Tsuda K; Tomobuchi Y; Akasaka T
    J Am Coll Cardiol; 2007 Sep; 50(10):933-9. PubMed ID: 17765119
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optical coherence tomography versus intravascular ultrasound to evaluate coronary artery disease and percutaneous coronary intervention.
    Bezerra HG; Attizzani GF; Sirbu V; Musumeci G; Lortkipanidze N; Fujino Y; Wang W; Nakamura S; Erglis A; Guagliumi G; Costa MA
    JACC Cardiovasc Interv; 2013 Mar; 6(3):228-36. PubMed ID: 23517833
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optical coherence tomography versus intravascular ultrasound in the evaluation of observer variability and reliability in the assessment of stent deployment: the OCTIVUS study.
    Magnus PC; Jayne JE; Garcia-Garcia HM; Swart M; van Es GA; Tijssen J; Kaplan AV
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):229-35. PubMed ID: 25620044
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.