These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

260 related articles for article (PubMed ID: 28582895)

  • 1. Implementation of integrated circuit and design of SAR ADC for fully implantable hearing aids.
    Kim JH; Lee JH; Cho JH
    Technol Health Care; 2017 Jul; 25(S1):83-92. PubMed ID: 28582895
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A 14-Bit Hybrid Analog-to-Digital Converter for Infrared Focal Plane Array Digital Readout Integrated Circuit.
    Hu D; Yao L; Chen N; Zhang J; Zhong S; Mao W; Zhu F; Zhang J
    Sensors (Basel); 2024 Jun; 24(11):. PubMed ID: 38894443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A 10-Bit 400-KS/s Low Noise Asynchronous SAR ADC with Dual-Domain Comparator for Input-Referred Noise Reduction.
    Lee SH; Lee WY
    Sensors (Basel); 2022 Aug; 22(16):. PubMed ID: 36015841
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Design of 10-Bit Asynchronous SAR ADC with an On-Chip Bandgap Reference Voltage Generator.
    Verma D; Shehzad K; Kim SJ; Pu YG; Yoo SS; Hwang KC; Yang Y; Lee KY
    Sensors (Basel); 2022 Jul; 22(14):. PubMed ID: 35891072
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A 155 μ W 88-dB DR discrete-time ∆Σ modulator for digital hearing aids exploiting a summing SAR ADC quantizer.
    Porrazzo S; Morgado A; San Segundo Bello D; Cannillo F; Van Hoof C; Yazicioglu RF; van Roermund AH; Cantatore E
    IEEE Trans Biomed Circuits Syst; 2013 Oct; 7(5):573-82. PubMed ID: 24232624
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A 7.6-nW 1-kS/s 10-Bit SAR ADC for Biomedical Applications.
    Hu Y; Tang B; Hu L; Liang H; Li B; Wu Z; Liu X
    Micromachines (Basel); 2022 Nov; 13(12):. PubMed ID: 36557409
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 16-Channel biphasic current-mode programmable charge balanced neural stimulation.
    Li X; Zhong S; Morizio J
    Biomed Eng Online; 2017 Aug; 16(1):104. PubMed ID: 28806960
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An Ultra-Low Power Charge Redistribution Successive Approximation Register A/D Converter for Biomedical Applications.
    Koppa S; Mohandesi M; John E
    J Low Power Electron; 2016 Dec; 12(4):385-393. PubMed ID: 29553147
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Low Power Sigma-Delta Modulator with Hybrid Architecture.
    An S; Xia S; Ma Y; Ghani A; See CH; Abd-Alhameed RA; Niu C; Yang R
    Sensors (Basel); 2020 Sep; 20(18):. PubMed ID: 32948053
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 0.3V 10b 3MS/s SAR ADC With Comparator Calibration and Kickback Noise Reduction for Biomedical Applications.
    Wang SH; Hung CC
    IEEE Trans Biomed Circuits Syst; 2020 Jun; 14(3):558-569. PubMed ID: 32224463
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A 9-10-Bit Adjustable and Energy-Efficient Switching Scheme for Successive Approximation Register Analog-to-Digital Converter with One Least Significant Bit Common-Mode Voltage Variation.
    Hu Y; Chen C; Hu L; Huang Q; Tang B; Hu M; Yuan B; Wu Z; Li B
    Sensors (Basel); 2024 May; 24(11):. PubMed ID: 38894065
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A 10-Bit 300 kS/s Reference-Voltage Regulator Free SAR ADC for Wireless-Powered Implantable Medical Devices.
    Yang Y; Zhou J; Liu X; Goh WL
    Sensors (Basel); 2018 Jul; 18(7):. PubMed ID: 29970814
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adaptive Resolution ADC Array for an Implantable Neural Sensor.
    O'Driscoll S; Shenoy KV; Meng TH
    IEEE Trans Biomed Circuits Syst; 2011 Apr; 5(2):120-30. PubMed ID: 23851200
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A 13-bit Noise Shaping SAR-ADC with Dual-Polarity Digital Calibration.
    Park H; Ghovanloo M
    Analog Integr Circuits Signal Process; 2013 Jun; 75(3):459-465. PubMed ID: 23682207
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-Speed Fully Differential Two-Step ADC Design Method for CMOS Image Sensor.
    Guo Z; Wang Y; Xu R; Yu N
    Sensors (Basel); 2023 Jan; 23(2):. PubMed ID: 36679391
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A 1.33 μW 8.02-ENOB 100 kS/s successive approximation ADC with supply reduction technique for implantable retinal prosthesis.
    Tang H; Sun ZC; Chew KW; Siek L
    IEEE Trans Biomed Circuits Syst; 2014 Dec; 8(6):844-56. PubMed ID: 25608284
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A 1.15 μW 200 kS/s 10-b Monotonic SAR ADC Using Dual On-Chip Calibrations and Accuracy Enhancement Techniques.
    Lee JH; Park D; Cho W; Phan HN; Nguyen CL; Lee JW
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30332815
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Digital-Analog Hybrid System-on-Chip for Capacitive Sensor Measurement and Control.
    Gao Z; Zhou B; Li X; Yang L; Wei Q; Zhang R
    Sensors (Basel); 2021 Jan; 21(2):. PubMed ID: 33435399
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Low-Power 12-Bit 20 MS/s Asynchronously Controlled SAR ADC for WAVE ITS Sensor Based Applications.
    Shehzad K; Verma D; Khan D; Ain QU; Basim M; Kim SJ; Rikan BS; Pu YG; Hwang KC; Yang Y; Lee KY
    Sensors (Basel); 2021 Mar; 21(7):. PubMed ID: 33804902
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A 1.72μW, 23.2fj/conversion step successive approach ADC for bio-medical signal acquisition.
    Wang WS; Tang KT
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():2703-6. PubMed ID: 22254899
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.