These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 28588330)

  • 21. Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep.
    Richter H; Plecko M; Andermatt D; Frigg R; Kronen PW; Klein K; Nuss K; Ferguson SJ; Stöckle U; von Rechenberg B
    J Bone Joint Surg Am; 2015 Feb; 97(3):208-15. PubMed ID: 25653321
    [TBL] [Abstract][Full Text] [Related]  

  • 22. In vitro biomechanical comparison of a plate-rod combination-construct and an interlocking nail-construct for experimentally induced gap fractures in canine tibiae.
    von Pfeil DJ; Déjardin LM; DeCamp CE; Meyer EG; Lansdowne JL; Weerts RJ; Haut RC
    Am J Vet Res; 2005 Sep; 66(9):1536-43. PubMed ID: 16261826
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Common long bone fracture in small animal practice--part 2.
    Harasen G
    Can Vet J; 2003 Jun; 44(6):503-4. PubMed ID: 12839248
    [No Abstract]   [Full Text] [Related]  

  • 24. A comparison of lateral fixation versus dual plating for simple bicondylar fractures.
    Yao Y; Lv H; Zan J; Zhang J; Zhu N; Ning R; Jing J
    Knee; 2015 Jun; 22(3):225-9. PubMed ID: 25747747
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
    Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
    Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fracture Repair in Cats Using a Conical Coupling Mini 1.9 to 2.5 mm Locking Plate System.
    Ferrero FC; Baroncelli AB; Hudson CC; Peirone B; Reif U; Piras LA
    Vet Comp Orthop Traumatol; 2020 Nov; 33(6):443-450. PubMed ID: 32951192
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Lateral Locked Plating or Dual Plating: A Comparison of Two Methods in Simple Bicondylar Tibial Plateau Fractures.
    Citak C; Kayali C; Ozan F; Altay T; Karahan HG; Yamak K
    Clin Orthop Surg; 2019 Jun; 11(2):151-158. PubMed ID: 31156765
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.
    Ma CH; Tu YK; Yeh JH; Yang SC; Wu CH
    J Trauma; 2011 Sep; 71(3):614-9. PubMed ID: 21768910
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Are Locked Plates Needed for Split Depression Tibial Plateau Fractures?
    Abghari M; Marcano A; Davidovitch R; Konda SR; Egol KA
    J Knee Surg; 2016 Aug; 29(6):482-6. PubMed ID: 26571049
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Tibial plateau levelling osteotomy locking-compression plates for stabilisation of canine and feline ilial body fractures.
    Guthrie JW; Kalff S
    J Small Anim Pract; 2018 Apr; 59(4):232-237. PubMed ID: 29230821
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Minimally Invasive Plate Osteosynthesis Using Fracture Reduction Under the Plate without Intraoperative Fluoroscopy to Stabilize Diaphyseal Fractures of the Tibia and Femur in Dogs and Cats.
    Cabassu J
    Vet Comp Orthop Traumatol; 2019 Nov; 32(6):475-482. PubMed ID: 31357218
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Use of wire sutures to stabilize fractures.
    Clark JH
    Mod Vet Pract; 1971 May; 52(5):63-7. PubMed ID: 5159973
    [No Abstract]   [Full Text] [Related]  

  • 33. Ultrasonographic assessment of fracture healing after plate osteosynthesis.
    Risselada M; van Bree H; Kramer M; Duchateau L; Verleyen P; Saunders JH
    Vet Radiol Ultrasound; 2007; 48(4):368-72. PubMed ID: 17691638
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Absolute or relative stability in minimal invasive plate osteosynthesis of simple distal meta or diaphyseal tibia fractures?
    Wenger R; Oehme F; Winkler J; Perren SM; Babst R; Beeres FJP
    Injury; 2017 Jun; 48(6):1217-1223. PubMed ID: 28302305
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Tibial fractures.
    Seaman JA; Simpson AM
    Clin Tech Small Anim Pract; 2004 Aug; 19(3):151-67. PubMed ID: 15712461
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Percutaneous tibial physeal fracture repair in small animals: technique and 17 cases.
    von Pfeil DJF; Glassman M; Ropski M
    Vet Comp Orthop Traumatol; 2017 Jul; 30(4):279-287. PubMed ID: 28636058
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Linear external skeletal fixation applied in minimally invasive fashion for stabilization of nonarticular tibial fractures in dogs and cats.
    Sherman AH; Kraus KH; Watt D; Yuan L; Mochel JP
    Vet Surg; 2023 Feb; 52(2):249-256. PubMed ID: 36382668
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Minimally invasive metatarsal fracture repair with locking plates in a guanaco (Lama guanicoe).
    Bertuglia A; Piga S; Bullone M; Piras L; von Degerfeld MM
    J Zoo Wildl Med; 2014 Dec; 45(4):915-8. PubMed ID: 25632682
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study.
    Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U
    Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Open reduction and bone plate stabilization, compared with closed reduction and external fixation, for treatment of comminuted tibial fractures: 47 cases (1980-1995) in dogs.
    Dudley M; Johnson AL; Olmstead M; Smith CW; Schaeffer DJ; Abbuehl U
    J Am Vet Med Assoc; 1997 Oct; 211(8):1008-12. PubMed ID: 9343545
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.