These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

402 related articles for article (PubMed ID: 28590998)

  • 41. A Comparison of 3 Videolaryngoscopes for Double-Lumen Tube Intubation in Humans by Users With Mixed Experience: A Randomized Controlled Study.
    El-Tahan MR; Khidr AM; Gaarour IS; Alshadwi SA; Alghamdi TM; Al'ghamdi A
    J Cardiothorac Vasc Anesth; 2018 Feb; 32(1):277-286. PubMed ID: 29056498
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Comparison of VividTrac®, Airtraq®, King Vision®, Macintosh Laryngoscope and a Custom-Made Videolaryngoscope for difficult and normal airways in mannequins by novices.
    Rendeki S; Keresztes D; Woth G; Mérei Á; Rozanovic M; Rendeki M; Farkas J; Mühl D; Nagy B
    BMC Anesthesiol; 2017 May; 17(1):68. PubMed ID: 28549421
    [TBL] [Abstract][Full Text] [Related]  

  • 43. [Endotracheal intubation with the GlideScope®, the Airtraq®, the McGrath® videolaryngoscope and direct laryngoscopy: a comparative study on an infant manikin].
    Orliaguet GA; Blot RM; Bourdaud N; Egan M; Dogaru E; Salvi N; Gall O; Carli P
    Ann Fr Anesth Reanim; 2013 Dec; 32(12):844-9. PubMed ID: 24176721
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The GlideScope Ranger video laryngoscope can be useful in airway management of entrapped patients.
    Nakstad AR; Sandberg M
    Acta Anaesthesiol Scand; 2009 Nov; 53(10):1257-61. PubMed ID: 19681773
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study.
    Schieren M; Kleinschmidt J; Schmutz A; Loop T; Staat M; Gatzweiler KH; Wappler F; Defosse J
    Anaesthesia; 2019 Dec; 74(12):1563-1571. PubMed ID: 31448404
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Comparison of intubation through the McGrath MAC, GlideScope, AirTraq, and Miller Laryngoscope by paramedics during child CPR: a randomized crossover manikin trial.
    Szarpak L; Karczewska K; Evrin T; Kurowski A; Czyzewski L
    Am J Emerg Med; 2015 Jul; 33(7):946-50. PubMed ID: 25937380
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Educational suitability of endotracheal intubation using a video-laryngoscope].
    Choo HJ; Kwon OY; Ko YG
    Korean J Med Educ; 2015 Dec; 27(4):267-74. PubMed ID: 26657548
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A Comparison of Paramedic First Pass Endotracheal Intubation Success Rate of the VividTrac VT-A 100, GlideScope Ranger, and Direct Laryngoscopy Under Simulated Prehospital Cervical Spinal Immobilization Conditions in a Cadaveric Model.
    Hodnick R; Zitek T; Galster K; Johnson S; Bledsoe B; Ebbs D
    Prehosp Disaster Med; 2017 Dec; 32(6):621-624. PubMed ID: 28807073
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparison of blind intubation via supraglottic airway devices versus standard intubation during different airway emergency scenarios in inexperienced hand: Randomized, crossover manikin trial.
    Bielski A; Rivas E; Ruetzler K; Smereka J; Puslecki M; Dabrowski M; Ladny JR; Frass M; Robak O; Evrin T; Szarpak L
    Medicine (Baltimore); 2018 Oct; 97(40):e12593. PubMed ID: 30290627
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A comparison of the Glidescope, Pentax AWS, and Macintosh laryngoscopes when used by novice personnel: a manikin study.
    Malik MA; Hassett P; Carney J; Higgins BD; Harte BH; Laffey JG
    Can J Anaesth; 2009 Nov; 56(11):802-11. PubMed ID: 19655213
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A comparison between the GlideScope® classic and GlideScope® direct video laryngoscopes and direct laryngoscopy for nasotracheal intubation.
    Heuer JF; Heitmann S; Crozier TA; Bleckmann A; Quintel M; Russo SG
    J Clin Anesth; 2016 Sep; 33():330-6. PubMed ID: 27555188
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparison of three video laryngoscopy devices to direct laryngoscopy for intubating obese patients: a randomized controlled trial.
    Yumul R; Elvir-Lazo OL; White PF; Sloninsky A; Kaplan M; Kariger R; Naruse R; Parker N; Pham C; Zhang X; Wender RH
    J Clin Anesth; 2016 Jun; 31():71-7. PubMed ID: 27185681
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Inverse intubation in entrapped trauma casualties: a simulator based, randomised cross-over comparison of direct, indirect and video laryngoscopy.
    Schober P; Krage R; van Groeningen D; Loer SA; Schwarte LA
    Emerg Med J; 2014 Dec; 31(12):959-63. PubMed ID: 24005641
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparison of the ETView Single Lumen and Macintosh laryngoscopes for endotracheal intubation in an airway manikin with immobilized cervical spine by novice paramedics: A randomized crossover manikin trial.
    Gawlowski P; Smereka J; Madziala M; Cohen B; Ruetzler K; Szarpak L
    Medicine (Baltimore); 2017 Apr; 96(16):e5873. PubMed ID: 28422820
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparative evaluation of Airtraq™ and GlideScope® videolaryngoscopes for difficult pediatric intubation in a Pierre Robin manikin.
    Desai N; Johnson M; Priddis K; Ray S; Chigaru L
    Eur J Pediatr; 2019 Jul; 178(7):1105-1111. PubMed ID: 31119438
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparison of intubation conditions with CMAC Miller videolaryngoscope and conventional Miller laryngoscope in lateral position in infants: A prospective randomized trial.
    Jain D; Mehta S; Gandhi K; Arora S; Parikh B; Abas M
    Paediatr Anaesth; 2018 Mar; 28(3):226-230. PubMed ID: 29316004
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Comparison of conventional and videolaryngoscopy blades in neonates.
    Kirolos S; O'Shea JE
    Arch Dis Child Fetal Neonatal Ed; 2020 Jan; 105(1):94-97. PubMed ID: 30606750
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: a manikin study.
    Savoldelli GL; Schiffer E; Abegg C; Baeriswyl V; Clergue F; Waeber JL
    Eur J Anaesthesiol; 2009 Jul; 26(7):554-8. PubMed ID: 19522050
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of the McGrath
    Giraudon A; Bordes-Demolis M; Blondeau B; Sibai de Panthou N; Ferrand N; Bello M; Dahlet V; Semjen F; Biais M; Nouette-Gaulain K
    Anaesth Crit Care Pain Med; 2017 Oct; 36(5):261-265. PubMed ID: 28323237
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.