These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 28595853)

  • 1. Acoustically Active Catheter for Intracardiac Navigation by Color Doppler Ultrasonography.
    Katayama M; Zarbatany D; Cha SS; Fatemi M; Belohlavek M
    Ultrasound Med Biol; 2017 Sep; 43(9):1888-1896. PubMed ID: 28595853
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Real-time Color Doppler Marker for Echocardiographic Guidance of an Acoustically Active Extracorporeal Membrane Oxygenation Cannula.
    Belohlavek M; Katayama M; Vaitkus VV; Kumar V; Fatemi M; Grabham J; Sandweiss B
    J Ultrasound Med; 2019 Jul; 38(7):1875-1885. PubMed ID: 30419612
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Acoustically active injection catheter guided by ultrasound: navigation tests in acutely ischemic porcine hearts.
    Belohlavek M; Katayama M; Zarbatany D; Fortuin FD; Fatemi M; Nenadic IZ; McMahon EM
    Ultrasound Med Biol; 2014 Jul; 40(7):1650-9. PubMed ID: 24785441
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Color Doppler imaging of cardiac catheters using vibrating motors.
    Reddy KE; Light ED; Rivera DJ; Kisslo JA; Smith SW
    Ultrason Imaging; 2008 Oct; 30(4):247-50. PubMed ID: 19514134
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Epicardial ultrasound guidance of coronary catheter placement in an experimental animal model.
    Anagnostopoulos PC; Pislaru C; Seward JB; Belohlavek M
    J Am Soc Echocardiogr; 2002 Nov; 15(11):1387-90. PubMed ID: 12415233
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Percutaneous vascular and nonvascular puncture under US guidance: role of color Doppler imaging.
    Longo JM; Bilbao JI; Barettino MD; Larrea JA; Pueyo J; Idoate F; deVilla VH
    Radiographics; 1994 Sep; 14(5):959-72. PubMed ID: 7991826
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Full performance of modern echocardiography within the heart: in-vivo feasibility study with a new intracardiac, phased-array ultrasound-tipped catheter.
    Caspari GH; Müller S; Bartel T; Koopmann J; Erbel R
    Eur J Echocardiogr; 2001 Jun; 2(2):100-7. PubMed ID: 11882436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Unambiguous Identification and Visualization of an Acoustically Active Catheter by Ultrasound Imaging in Real Time: Theory, Algorithm, and Phantom Experiments.
    Kumar V; Liu R; Kinnick RR; Gregory A; Alizad A; Belohlavek M; Fatemi M
    IEEE Trans Biomed Eng; 2018 Jul; 65(7):1468-1475. PubMed ID: 28952929
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.
    Stephens DN; Cannata J; Liu R; Zhao JZ; Shung KK; Nguyen H; Chia R; Dentinger A; Wildes D; Thomenius KE; Mahajan A; Shivkumar K; Kim K; O'Donnell M; Nikoozadeh A; Oralkan O; Khuri-Yakub PT; Sahn DJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jul; 55(7):1570-81. PubMed ID: 18986948
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accurate guidance of a catheter by ultrasound imaging and identification of a catheter tip by pulsed-wave Doppler.
    McMahon EM; Jiamsripong P; Katayama M; Chaliki HP; Fatemi M; Belohlavek M
    Pacing Clin Electrophysiol; 2012 Jan; 35(1):44-50. PubMed ID: 22054263
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of an electrophysiology (EP)-enabled intracardiac ultrasound catheter integrated with NavX 3-dimensional electrofield mapping for guiding cardiac EP interventions: experimental studies.
    Li XK; Pemberton J; Thomenius K; Dentinger A; Lowe RI; Ashraf M; Shung KK; Chia R; Stephens DN; O'Donnell M; Mahajan A; Balaji S; Shivkumar K; Sahn DJ
    J Ultrasound Med; 2007 Nov; 26(11):1565-74. PubMed ID: 17957051
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Identification of location of nerve catheters using pumping maneuver and M-Mode-a novel technique.
    Elsharkawy H; Salmasi V; Abd-Elsayed A; Turan A
    J Clin Anesth; 2015 Jun; 27(4):325-30. PubMed ID: 25837495
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Doppler catheter tip localization using color enhancement.
    Frazin LJ; Vonesh MJ; Yaacoub AS; Kane BJ; Greene R; Kemper WS; Guberek M; McPherson DD
    Cathet Cardiovasc Diagn; 1994 May; 32(1):62-9. PubMed ID: 8039223
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intracardiac phased-array imaging: methods and initial clinical experience with high resolution, under blood visualization: initial experience with intracardiac phased-array ultrasound.
    Packer DL; Stevens CL; Curley MG; Bruce CJ; Miller FA; Khandheria BK; Oh JK; Sinak LJ; Seward JB
    J Am Coll Cardiol; 2002 Feb; 39(3):509-16. PubMed ID: 11823090
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intrapericardial echocardiography: a novel catheter-based approach to cardiac imaging.
    Rodrigues AC; d'Avila A; Houghtaling C; Ruskin JN; Picard M; Reddy VY
    J Am Soc Echocardiogr; 2004 Mar; 17(3):269-74. PubMed ID: 14981426
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cannulation of the aortic branches using ultrasound guidance. An animal study.
    Frazin LJ; Wiet SP; Yaacoub AS; Kane BJ; Greene R; Vonesh MJ
    ASAIO J; 1997; 43(4):321-5. PubMed ID: 9242947
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accurate conductance-based post-dilation balloon catheter sizing.
    Svendsen MC; Sinha AK; Hermiller JB; Bhatt DL; Jansen B; Berwick ZC; Kemp A; Combs W; Kassab G
    JACC Cardiovasc Imaging; 2015 May; 8(5):618-620. PubMed ID: 25457760
    [No Abstract]   [Full Text] [Related]  

  • 18. Doppler-Guided Acoustically Active Injection Catheter: Transendocardial Delivery Assessed by an Efficacy Testing Animal Model.
    Katayama M; Gades NM; Singh VP; Devick KL; Zarbatany D; Vaitkus VV; Belohlavek DL; Fortuin FD; Belohlavek M
    J Ultrasound Med; 2022 Mar; 41(3):749-762. PubMed ID: 33938031
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of colour Doppler and M-mode ultrasonography to confirm the location of an epidural catheter - a retrospective case series.
    Elsharkawy H; Sonny A; Govindarajan SR; Chan V
    Can J Anaesth; 2017 May; 64(5):489-496. PubMed ID: 28074426
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-time 3D color flow Doppler for guidance of vibrating interventional devices.
    Fronheiser MP; Wolf PD; Idriss SF; Nelson RC; Lee W; Smith SW
    Ultrason Imaging; 2004 Jul; 26(3):173-84. PubMed ID: 15754798
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.