BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 28599255)

  • 1. Research on two-port network of wavelet transform processor using surface acoustic wavelet devices and its application.
    Liu S; Lu W; Zhu C
    Ultrasonics; 2017 Nov; 81():81-85. PubMed ID: 28599255
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implementing wavelet inverse-transform processor with surface acoustic wave device.
    Lu W; Zhu C; Liu Q; Zhang J
    Ultrasonics; 2013 Feb; 53(2):447-54. PubMed ID: 23036148
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Study of low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices.
    Jiang H; Lu W; Zhang G
    Ultrasonics; 2013 Jul; 53(5):992-7. PubMed ID: 23399004
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Admittance matrix of a surface acoustic wave interdigital transducer.
    Soluch W
    IEEE Trans Ultrason Ferroelectr Freq Control; 1993; 40(6):828-31. PubMed ID: 18263253
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Scattering Matrix Approach to Design of One-Port Surface Acoustic Wave Resonator Sensors Utilizing Reflectors as Sensing Element.
    Kesuma HP; Ramakrishnan N; Lan BL; Dhillon AS; Achath Mohanan A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Apr; 68(4):1418-1429. PubMed ID: 33064646
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experimental and numerical investigations of mechanical displacements in surface acoustic wave bounded beams.
    Weser R; Darinskii AN; Weihnacht M; Schmidt H
    Ultrasonics; 2020 Aug; 106():106077. PubMed ID: 32305680
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effective and rapid technique for temporal response modeling of surface acoustic wave interdigital transducers.
    Fall D; Duquennoy M; Ouaftouh M; Piwakowski B; Jenot F
    Ultrasonics; 2018 Jan; 82():371-378. PubMed ID: 28988142
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple equivalent circuit for interdigital transducers based on the coupled-mode approach.
    Nakamura K
    IEEE Trans Ultrason Ferroelectr Freq Control; 1993; 40(6):763-7. PubMed ID: 18263244
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimization of broadband withdrawal weighted interdigital transducers for high selective SAW filters.
    Bausk EV
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(5):1276-82. PubMed ID: 18244320
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design of SAW synchronous resonators on ST cut quartz.
    Soluch W
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(5):1324-6. PubMed ID: 18244325
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measuring Velocity, Attenuation, and Reflection in Surface Acoustic Wave Cavities Through Acoustic Fabry-PĂ©rot Spectra.
    Kelly L; Berini P; Bao X
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Apr; 69(4):1542-1548. PubMed ID: 35081023
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical analysis of wave generation and propagation in a focused surface acoustic wave device for potential microfluidics applications.
    Sankaranarayanan SK; Bhethanabotla VR
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Mar; 56(3):631-43. PubMed ID: 19411221
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic computer-aided design of SAW filters using slanted finger interdigital transducers.
    Yatsuda H; Yamanouchi K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(1):140-7. PubMed ID: 18238525
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design considerations on surface acoustic wave resonators with significant internal reflection in interdigital transducers.
    Hashimoto KY; Omori T; Yamaguchi M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2004 Nov; 51(11):1394-403. PubMed ID: 15600082
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A study of crosstalk effects on the packaged SAW by the FDTD method.
    Lin KY; Lin KH
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Mar; 52(3):445-54. PubMed ID: 15857053
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Single Interdigital Transducer Approach for Gravimetrical SAW Sensor Applications in Liquid Environments.
    Nguyen VH; Kaulen C; Simon U; Schnakenberg U
    Sensors (Basel); 2017 Dec; 17(12):. PubMed ID: 29258213
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The complexity of surface acoustic wave fields used for microfluidic applications.
    Weser R; Winkler A; Weihnacht M; Menzel S; Schmidt H
    Ultrasonics; 2020 Aug; 106():106160. PubMed ID: 32334142
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of bulk wave radiation on IDT admittance on 42 degrees YX-LiTaO3.
    Hashimoto K; Yamaguchi M; Kovacs G; Wagner KC; Ruile W; Weigel R
    IEEE Trans Ultrason Ferroelectr Freq Control; 2001 Sep; 48(5):1419-25. PubMed ID: 11570768
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel compensation method of insertion losses for wavelet inverse-transform processors using surface acoustic wave devices.
    Lu W; Zhu C
    Rev Sci Instrum; 2011 Nov; 82(11):115003. PubMed ID: 22129005
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface acoustic wave properties of (100) AlN films on diamond with different IDT positions.
    Lin ZX; Wu S; Ro R; Lee MS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Jun; 56(6):1246-51. PubMed ID: 19574132
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.