These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 28601779)

  • 1. Determining oxygen relaxations at an interface: A comparative study between transmission electron microscopy techniques.
    Gauquelin N; van den Bos KHW; Béché A; Krause FF; Lobato I; Lazar S; Rosenauer A; Van Aert S; Verbeeck J
    Ultramicroscopy; 2017 Oct; 181():178-190. PubMed ID: 28601779
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Locating light and heavy atomic column positions with picometer precision using ISTEM.
    van den Bos KH; Krause FF; Béché A; Verbeeck J; Rosenauer A; Van Aert S
    Ultramicroscopy; 2017 Jan; 172():75-81. PubMed ID: 27889636
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dose efficient annular bright field contrast with the ISTEM method: A proof of principle demonstration.
    Krause FF; Schowalter M; Gerken B; Marquardt D; Grieb T; Mehrtens T; Mahr C; Rosenauer A
    Ultramicroscopy; 2023 Mar; 245():113661. PubMed ID: 36529039
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Atom column detection from simultaneously acquired ABF and ADF STEM images.
    Fatermans J; den Dekker AJ; Müller-Caspary K; Gauquelin N; Verbeeck J; Van Aert S
    Ultramicroscopy; 2020 Dec; 219():113046. PubMed ID: 32927326
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new method to detect and correct sample tilt in scanning transmission electron microscopy bright-field imaging.
    Brown HG; Ishikawa R; Sánchez-Santolino G; Lugg NR; Ikuhara Y; Allen LJ; Shibata N
    Ultramicroscopy; 2017 Feb; 173():76-83. PubMed ID: 27987470
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Phase contrast scanning transmission electron microscopy imaging of light and heavy atoms at the limit of contrast and resolution.
    Yücelen E; Lazić I; Bosch EGT
    Sci Rep; 2018 Feb; 8(1):2676. PubMed ID: 29422551
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative comparison of bright field and annular bright field imaging modes for characterization of oxygen octahedral tilts.
    Kim YM; Pennycook SJ; Borisevich AY
    Ultramicroscopy; 2017 Oct; 181():1-7. PubMed ID: 28478345
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of chromatic aberration on atomic-resolved spherical aberration corrected STEM images.
    Kuramochi K; Yamazaki T; Kotaka Y; Ohtsuka M; Hashimoto I; Watanabe K
    Ultramicroscopy; 2009 Dec; 110(1):36-42. PubMed ID: 19818560
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficient elastic imaging of single atoms on ultrathin supports in a scanning transmission electron microscope.
    Hovden R; Muller DA
    Ultramicroscopy; 2012 Dec; 123():59-65. PubMed ID: 22727335
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sample tilt effects on atom column position determination in ABF-STEM imaging.
    Zhou D; Müller-Caspary K; Sigle W; Krause FF; Rosenauer A; van Aken PA
    Ultramicroscopy; 2016 Jan; 160():110-117. PubMed ID: 26479323
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spatially resolved diffractometry with atomic-column resolution.
    Kimoto K; Ishizuka K
    Ultramicroscopy; 2011 Jul; 111(8):1111-6. PubMed ID: 21740874
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of two-dimensional crystallography and image processing to atomic resolution Z-contrast images.
    Morgan DG; Ramasse QM; Browning ND
    J Electron Microsc (Tokyo); 2009 Jun; 58(3):223-44. PubMed ID: 19297343
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atom-counting in High Resolution Electron Microscopy:TEM or STEM - That's the question.
    Gonnissen J; De Backer A; den Dekker AJ; Sijbers J; Van Aert S
    Ultramicroscopy; 2017 Mar; 174():112-120. PubMed ID: 28278434
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analytical ABF-STEM imaging of Li ions in rechargeable batteries.
    Wen Y; Shang T; Gu L
    Microscopy (Oxf); 2017 Feb; 66(1):25-38. PubMed ID: 27856513
    [TBL] [Abstract][Full Text] [Related]  

  • 15. StatSTEM: An efficient approach for accurate and precise model-based quantification of atomic resolution electron microscopy images.
    De Backer A; van den Bos KHW; Van den Broek W; Sijbers J; Van Aert S
    Ultramicroscopy; 2016 Dec; 171():104-116. PubMed ID: 27657649
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Estimation of unknown structure parameters from high-resolution (S)TEM images: what are the limits?
    den Dekker AJ; Gonnissen J; De Backer A; Sijbers J; Van Aert S
    Ultramicroscopy; 2013 Nov; 134():34-43. PubMed ID: 23820594
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative atomic resolution mapping using high-angle annular dark field scanning transmission electron microscopy.
    Van Aert S; Verbeeck J; Erni R; Bals S; Luysberg M; Van Dyck D; Van Tendeloo G
    Ultramicroscopy; 2009 Sep; 109(10):1236-44. PubMed ID: 19525069
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Picometer-scale atom position analysis in annular bright-field STEM imaging.
    Gao P; Kumamoto A; Ishikawa R; Lugg N; Shibata N; Ikuhara Y
    Ultramicroscopy; 2018 Jan; 184(Pt A):177-187. PubMed ID: 28934631
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dose limited reliability of quantitative annular dark field scanning transmission electron microscopy for nano-particle atom-counting.
    De Backer A; Martinez GT; MacArthur KE; Jones L; Béché A; Nellist PD; Van Aert S
    Ultramicroscopy; 2015 Apr; 151():56-61. PubMed ID: 25511931
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Imaging biological samples by integrated differential phase contrast (iDPC) STEM technique.
    Li X; Lazić I; Huang X; Wirix M; Wang L; Deng Y; Niu T; Wu D; Yu L; Sun F
    J Struct Biol; 2022 Mar; 214(1):107837. PubMed ID: 35104612
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.