These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 28602298)

  • 1. Some practical considerations for linearity assessment of calibration curves as function of concentration levels according to the fitness-for-purpose approach.
    Jurado JM; Alcázar A; Muñiz-Valencia R; Ceballos-Magaña SG; Raposo F
    Talanta; 2017 Sep; 172():221-229. PubMed ID: 28602298
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calibration and validation of linearity in chromatographic biopharmaceutical analysis.
    Karnes HT; March C
    J Pharm Biomed Anal; 1991; 9(10-12):911-8. PubMed ID: 1822211
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percent residual accuracy for quantifying goodness-of-fit of linear calibration curves.
    Logue BA; Manandhar E
    Talanta; 2018 Nov; 189():527-533. PubMed ID: 30086955
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and analytical validation of a multivariate calibration method for determination of amoxicillin in suspension formulations by near infrared spectroscopy.
    Silva MA; Ferreira MH; Braga JW; Sena MM
    Talanta; 2012 Jan; 89():342-51. PubMed ID: 22284501
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of different linear calibration approaches for LC-MS bioanalysis.
    Tan A; Awaiye K; Jose B; Joshi P; Trabelsi F
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Dec; 911():192-202. PubMed ID: 23217324
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flexibility and applicability of β-expectation tolerance interval approach to assess the fitness of purpose of pharmaceutical analytical methods.
    Bouabidi A; Talbi M; Bourichi H; Bouklouze A; El Karbane M; Boulanger B; Brik Y; Hubert P; Rozet E
    Drug Test Anal; 2012 Dec; 4(12):1014-27. PubMed ID: 22615163
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Practical guidelines for reporting results in single- and multi-component analytical calibration: a tutorial.
    Olivieri AC
    Anal Chim Acta; 2015 Apr; 868():10-22. PubMed ID: 25813230
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An IUPAC-based approach to estimate the detection limit in co-extraction-based optical sensors for anions with sigmoidal response calibration curves.
    Fernández-Ramos MD; Cuadros-Rodríguez L; Arroyo-Guerrero E; Capitán-Vallvey LF
    Anal Bioanal Chem; 2011 Nov; 401(9):2881-9. PubMed ID: 21898154
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Precision limits and interval estimation in the calibration of 1-hydroxypyrene in urine and hexachlorbenzene in water, applying the regression triplet procedure on chromatographic data.
    Meloun M; Dluhosová Z
    Anal Bioanal Chem; 2008 Apr; 390(7):1899-910. PubMed ID: 18264698
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multielement trace determination in SiC powders: assessment of interlaboratory comparisons aimed at the validation and standardization of analytical procedures with direct solid sampling based on ETV ICP OES and DC arc OES.
    Matschat R; Hassler J; Traub H; Dette A
    Anal Bioanal Chem; 2005 Dec; 383(7-8):1060-74. PubMed ID: 16079974
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Linearity and calibration. A clinical laboratory perspective.
    Passey RB; Maluf KC
    Arch Pathol Lab Med; 1992 Jul; 116(7):757-60. PubMed ID: 1497449
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of influential data, model and method on the precision of univariate calibration.
    Meloun M; Militký J; Kupka K; Brereton RG
    Talanta; 2002 Jun; 57(4):721-40. PubMed ID: 18968675
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of ELISA for the determination of anti-ricin immunoglobulin G concentration in mouse sera.
    Lindsey CY; Pace-Templeton JG; Millard CB; Wannemacher RW; Hewetson JF
    Biologicals; 2006 Mar; 34(1):33-41. PubMed ID: 16260147
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sensitivity deviation: instrumental linearity errors that influence concentration analyses and kinetic evaluation of biomolecular interactions.
    Johansen K; Lundström I; Liedberg B
    Biosens Bioelectron; 2000; 15(9-10):503-9. PubMed ID: 11419646
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Verifying performance characteristics of quantitative analytical systems: calibration verification, linearity, and analytical measurement range.
    Killeen AA; Long T; Souers R; Styer P; Ventura CB; Klee GG
    Arch Pathol Lab Med; 2014 Sep; 138(9):1173-81. PubMed ID: 25171699
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Correspondence of linearity evaluations to the performance of clinical chemistry instrument and reagent systems.
    Shires GW
    Arch Pathol Lab Med; 1992 Jul; 116(7):761-4. PubMed ID: 1497450
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Increasing the working calibration range by means of artificial neural networks for the determination of cadmium by graphite furnace atomic absorption spectrometry.
    Hernández-Caraballo EA; Avila-Gómez RM; Rivas F; Burguera M; Burguera JL
    Talanta; 2004 May; 63(2):425-31. PubMed ID: 18969450
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Worst case uncertainty estimates for routine instrumental analysis.
    da Silva RJ; Santos JR; Camões MF
    Analyst; 2002 Jul; 127(7):957-63. PubMed ID: 12173657
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Azithromycin assay in drug formulations: Validation of a HPTLC method with a quadratic polynomial calibration model using the accuracy profile approach.
    Bouklouze A; Kharbach M; Cherrah Y; Vander Heyden Y
    Ann Pharm Fr; 2017 Mar; 75(2):112-120. PubMed ID: 27692351
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of quality performance parameters for straight line calibration curves related to the spread of the abscissa values around their mean.
    De Beer JO; De Beer TR; Goeyens L
    Anal Chim Acta; 2007 Feb; 584(1):57-65. PubMed ID: 17386585
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.