These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 28604621)

  • 1. Development of a Rigid One-Meter-Side and Cooled Coil Sensor at 77 K for Magnetic Resonance Sounding to Detect Subsurface Water Sources.
    Lin J; Du G; Zhang J; Yi X; Jiang C; Lin T
    Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28604621
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design of a Matching Network for a High-Sensitivity Broadband Magnetic Resonance Sounding Coil Sensor.
    Zhang Y; Teng F; Li S; Wan L; Lin T
    Sensors (Basel); 2017 Oct; 17(11):. PubMed ID: 29076986
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor.
    Qin S; Ma Z; Jiang C; Lin J; Xue Y; Shang X; Li Z
    Sensors (Basel); 2017 Sep; 17(9):. PubMed ID: 28926929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range.
    Lin T; Zhang Y; Lee YH; Krause HJ; Lin J; Zhao J
    Rev Sci Instrum; 2014 Nov; 85(11):114708. PubMed ID: 25430134
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design of Meter-Scale Antenna and Signal Detection System for Underground Magnetic Resonance Sounding in Mines.
    Yi X; Zhang J; Fan T; Tian B; Jiang C
    Sensors (Basel); 2018 Mar; 18(3):. PubMed ID: 29534007
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-temperature superconducting radiofrequency probe for magnetic resonance imaging applications operated below ambient pressure in a simple liquid-nitrogen cryostat.
    Lambert S; Ginefri JC; Poirier-Quinot M; Darrasse L
    Rev Sci Instrum; 2013 May; 84(5):054701. PubMed ID: 23742569
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cryogenic receive coil and low noise preamplifier for MRI at 0.01T.
    Resmer F; Seton HC; Hutchison JM
    J Magn Reson; 2010 Mar; 203(1):57-65. PubMed ID: 20031458
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An ultralow noise current amplifier based on superconducting quantum interference device for high sensitivity applications.
    Granata C; Vettoliere A; Russo M
    Rev Sci Instrum; 2011 Jan; 82(1):013901. PubMed ID: 21280839
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Exploring on the Sensitivity Changes of the
    Lin T; Zhou K; Yu S; Wang P; Wan L; Zhao J
    Sensors (Basel); 2018 Apr; 18(5):. PubMed ID: 29693644
    [No Abstract]   [Full Text] [Related]  

  • 10. High-temperature superconducting quantum interference device with cooled LC resonant circuit for measuring alternating magnetic fields with improved signal-to-noise ratio.
    Qiu L; Zhang Y; Krause HJ; Braginski AI; Usoskin A
    Rev Sci Instrum; 2007 May; 78(5):054701. PubMed ID: 17552846
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Magnetic resonance sounding: new method for ground water assessment.
    Lubczynski M; Roy J
    Ground Water; 2004; 42(2):291-303. PubMed ID: 15035592
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hyperpolarized 13C MRS surface coil: design and signal-to-noise ratio estimation.
    Giovannetti G; Frijia F; Menichetti L; Milanesi M; Ardenkjaer-Larsen JH; De Marchi D; Hartwig V; Positano V; Landini L; Lombardi M; Santarelli MF
    Med Phys; 2010 Oct; 37(10):5361-9. PubMed ID: 21089771
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gradiometer pick-up coil design for a low field SQUID-MRI system.
    Seton HC; Hutchison JM; Bussell DM
    MAGMA; 1999 May; 8(2):116-20. PubMed ID: 10456374
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noise correlations and SNR in phased-array MRS.
    Martini N; Santarelli MF; Giovannetti G; Milanesi M; De Marchi D; Positano V; Landini L
    NMR Biomed; 2010 Jan; 23(1):66-73. PubMed ID: 19708042
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combined System of Magnetic Resonance Sounding and Time-Domain Electromagnetic Method for Water-Induced Disaster Detection in Tunnels.
    Shang X; Jiang C; Ma Z; Qin S
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30336630
    [TBL] [Abstract][Full Text] [Related]  

  • 16. First in vivo potassium-39 (³⁹K) MRI at 9.4 T using conventional copper radio frequency surface coil cooled to 77 K.
    Elabyad IA; Kalayciyan R; Shanbhag NC; Schad LR
    IEEE Trans Biomed Eng; 2014 Feb; 61(2):334-45. PubMed ID: 24448595
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Signal acquisition module design for multi-channel surface magnetic resonance sounding system.
    Lin T; Chen W; Du W; Zhao J
    Rev Sci Instrum; 2015 Nov; 86(11):114702. PubMed ID: 26628154
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An Optimized Air-Core Coil Sensor with a Magnetic Flux Compensation Structure Suitable to the Helicopter TEM System.
    Chen C; Liu F; Lin J; Zhu K; Wang Y
    Sensors (Basel); 2016 Apr; 16(4):. PubMed ID: 27077862
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Resolution of MRS applied to the characterization of hard-rock aquifers.
    Legchenko A; Descloitres M; Bost A; Ruiz L; Reddy M; Girard JF; Sekhar M; Mohan Kumar MS; Braun JJ
    Ground Water; 2006; 44(4):547-54. PubMed ID: 16857032
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation and Optimization of the Performance of an Air-Coil Sensor with a Differential Structure Suited to Helicopter TEM Exploration.
    Chen C; Liu F; Lin J; Wang Y
    Sensors (Basel); 2015 Sep; 15(9):23325-40. PubMed ID: 26389908
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.