425 related articles for article (PubMed ID: 28648427)
1. Asymptomatic late embolization of Amplatzer septal occluder device.
Nath RK; Pandit N
Indian Heart J; 2017; 69(3):338-340. PubMed ID: 28648427
[TBL] [Abstract][Full Text] [Related]
2. Transcatheter Retrieval of Embolized Atrial Septal Defect Occluder Device by Waist Capture Technique.
Her AY; Lim KH; Shin ES
Int Heart J; 2018 Jan; 59(1):226-228. PubMed ID: 29279534
[TBL] [Abstract][Full Text] [Related]
3. Late embolization of the atrial septal occluder device into the abdominal aorta.
Celik T; Ozturk C; Bozlar U; Iyisoy A
Indian Heart J; 2016; 68(2):200-1. PubMed ID: 27133338
[TBL] [Abstract][Full Text] [Related]
4. Aortic erosion occurring in over 5 years after Amplatzer septal Occluder implantation for secundum atrial septal defect: a case report.
Onakatomi Y; Asou T; Takeda Y; Ueda H; Goda M; Masuda M
J Cardiothorac Surg; 2019 Sep; 14(1):159. PubMed ID: 31492164
[TBL] [Abstract][Full Text] [Related]
5. Surgical rescue of embolized amplatzer devices.
Amanullah MM; Siddiqui MT; Khan MZ; Atiq MA
J Card Surg; 2011 May; 26(3):254-8. PubMed ID: 21480992
[TBL] [Abstract][Full Text] [Related]
6. Percutaneous Retrieval of Embolized Amplatzer Septal Occluder after Treatment of Double Atrial Septal Defect: A Case Report.
Cho JY; Kim KH; Yoon HJ; Seon HJ; Ahn Y; Jeong MH; Cho JG; Park JC
J Korean Med Sci; 2015 Sep; 30(9):1361-6. PubMed ID: 26339180
[TBL] [Abstract][Full Text] [Related]
7. Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder.
Lairakdomrong K; Srimahachota S; Lertsapcharoen P; Chaipromprasit J; Boonyaratavej S; Kaewsukkho P
J Med Assoc Thai; 2013 Sep; 96(9):1127-34. PubMed ID: 24163987
[TBL] [Abstract][Full Text] [Related]
8. Embolized Amplatzer septal occluder device presenting with ventricular fibrillation.
Yuce M; Ozer O; Cakici M; Cine N; Sari I; Davutoglu V
Cardiovasc Revasc Med; 2011; 12(2):131-2. PubMed ID: 21421193
[TBL] [Abstract][Full Text] [Related]
9. Erosion of an Amplatzer septal occluder device into the aortic root.
Kamouh A; Osman MN; Rosenthal N; Blitz A
Ann Thorac Surg; 2011 May; 91(5):1608-10. PubMed ID: 21524475
[TBL] [Abstract][Full Text] [Related]
10. Management of a large atrial septal occluder embolized to the left ventricular outflow tract without the use of cardiac surgery.
Loh JP; Satler LF; Slack MC
Catheter Cardiovasc Interv; 2014 Sep; 84(3):497-502. PubMed ID: 24403086
[TBL] [Abstract][Full Text] [Related]
11. Ceraflex versus Amplatzer occluder for secundum atrial septal defect closure. Multicenter clinical experience.
Astarcioglu MA; Kalcik M; Sen T; Aykan AC; Gokdeniz T; Gursoy OM; Karakoyun S; Kulahcioglu S; Gunduz S; Kilit C; Oylumlu M; Amasyali B
Herz; 2015 Apr; 40 Suppl 2():146-50. PubMed ID: 25662695
[TBL] [Abstract][Full Text] [Related]
12. Silent embolization of an atrial septal defect occluder into the right ventricle detected 20 months post-implantation.
Tang L; Fang ZF; Tang JJ; Shen XQ; Hu XQ; Zhou SH
Can J Cardiol; 2014 Nov; 30(11):1462.e17-8. PubMed ID: 25260939
[No Abstract] [Full Text] [Related]
13. [Transcatheter closure of atrial septal defects in adults. Practicality and safety of four different closure systems used in 102 patients].
La Rosée K; Krause D; Becker M; Beuckelmann DJ; Deutsch HJ; Höpp HW
Dtsch Med Wochenschr; 2001 Sep; 126(38):1030-6. PubMed ID: 11565056
[TBL] [Abstract][Full Text] [Related]
14. Real-time three-dimensional transesophageal echocardiography is useful for percutaneous closure of multiple secundum atrial septal defects.
Zhang C; Li Z; Xu J
Hellenic J Cardiol; 2014; 55(6):486-91. PubMed ID: 25432200
[TBL] [Abstract][Full Text] [Related]
15. Severe mitral valve insufficiency after transcatheter atrial septal defect closure with the amplatzer septal occluder: a device-related complication.
Li W; Han W; Yu C; Zhang C; Tu Z; Wu S; Huber CH; Ma L
J Card Surg; 2009; 24(6):672-4. PubMed ID: 20078713
[TBL] [Abstract][Full Text] [Related]
16. Percutaneous retrieval of an interatrial septal occluder device embolized into the aortic arch.
Pala S; Açar G; Tigen K; Kırma C
Turk Kardiyol Dern Ars; 2010 Oct; 38(7):502-4. PubMed ID: 21206207
[TBL] [Abstract][Full Text] [Related]
17. Transcatheter interatrial septal defect closure in a large cohort: midterm follow-up results.
Aytemir K; Oto A; Özkutlu S; Canpolat U; Kaya EB; Yorgun H; Şahiner L; Sunman H; Ateş AH; Kabakçı G
Congenit Heart Dis; 2013; 8(5):418-27. PubMed ID: 23601507
[TBL] [Abstract][Full Text] [Related]
18. Gore Cardioform atrial septal occluder: deployment procedure and techniques for closing challenging secundum atrial septal defects.
Aggarwal V; Mohan AK; Bass J; Steinberger J; Said SM; Qureshi AM
Cardiol Young; 2021 Dec; 31(12):1885-1892. PubMed ID: 34620264
[TBL] [Abstract][Full Text] [Related]
19. Very late erosion of Amplatzer occluder device resulting in Cardiac tamponade after 15 years.
Guelker JE; Jansen R; Sievert K; Sievert H; Bertog S
Clin Res Cardiol; 2018 Jun; 107(6):527-529. PubMed ID: 29484456
[No Abstract] [Full Text] [Related]
20. Aortic arch embolization of an Amplatzer occluder after an atrial septal defect closure: hybrid operative approach without circulatory arrest.
Costache V; Chavanon O; Thony F; Blin D
Eur J Cardiothorac Surg; 2005 Aug; 28(2):340-2. PubMed ID: 15939606
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]