These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 28650242)

  • 1. Evaluation of a telemetric gastrointestinal pill for continuous monitoring of gastrointestinal temperature in horses at rest and during exercise.
    Verdegaal EJMM; Delesalle C; Caraguel CGB; Folwell LE; McWhorter TJ; Howarth GS; Franklin SH
    Am J Vet Res; 2017 Jul; 78(7):778-784. PubMed ID: 28650242
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wireless measurement of rectal temperature during exercise: Comparing an ingestible thermometric telemetric pill used as a suppository against a conventional rectal probe.
    Gosselin J; Béliveau J; Hamel M; Casa D; Hosokawa Y; Morais JA; Goulet EDB
    J Therm Biol; 2019 Jul; 83():112-118. PubMed ID: 31331509
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An analysis of the effect of thermometer type and make on rectal temperature measurements of cattle, horses and sheep.
    Hine L; Laven RA; Sahu SK
    N Z Vet J; 2015 May; 63(3):171-3. PubMed ID: 25263731
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of two telemetric intestinal temperature devices with rectal temperature during exercise.
    Bogerd CP; Velt KB; Annaheim S; Bongers CCWG; Eijsvogels TMH; Daanen HAM
    Physiol Meas; 2018 Mar; 39(3):03NT01. PubMed ID: 29406308
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison between core temperatures measured telemetrically using the CorTemp® ingestible temperature sensor and rectal temperature in healthy Labrador retrievers.
    Osinchuk S; Taylor SM; Shmon CL; Pharr J; Campbell J
    Can Vet J; 2014 Oct; 55(10):939-45. PubMed ID: 25320380
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise.
    Bongers CC; Hopman MT; Eijsvogels TM
    J Vis Exp; 2015 Oct; (104):. PubMed ID: 26485169
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of cool water ingestion on gastrointestinal pill temperature.
    Wilkinson DM; Carter JM; Richmond VL; Blacker SD; Rayson MP
    Med Sci Sports Exerc; 2008 Mar; 40(3):523-8. PubMed ID: 18379216
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Gastrointestinal thermal homogeneity and effect of cold water ingestion.
    Roxane B; Ouma Chandrou K; Pierre Alexandre C; Christophe C; Bruno S; Stéphane B; Hervé N; Sébastien M; Nicolas B
    J Therm Biol; 2018 Dec; 78():204-208. PubMed ID: 30509636
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Telemetry pill versus rectal and esophageal temperature during extreme rates of exercise-induced core temperature change.
    Teunissen LP; de Haan A; de Koning JJ; Daanen HA
    Physiol Meas; 2012 Jun; 33(6):915-24. PubMed ID: 22551669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Telemetric measurement of body core temperature in exercising unconditioned Labrador retrievers.
    Angle TC; Gillette RL
    Can J Vet Res; 2011 Apr; 75(2):157-9. PubMed ID: 21731189
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Core temperature responses of military working dogs during training activities and exercise walks.
    O'Brien C; Karis AJ; Tharion WJ; Sullivan HM; Hoyt RW
    US Army Med Dep J; 2017; (3-17):71-78. PubMed ID: 29214623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of temperature readings from a percutaneous thermal sensing microchip with temperature readings from a digital rectal thermometer in equids.
    Robinson TR; Hussey SB; Hill AE; Heckendorf CC; Stricklin JB; Traub-Dargatz JL
    J Am Vet Med Assoc; 2008 Aug; 233(4):613-7. PubMed ID: 18710319
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Conventional and novel body temperature measurement during rest and exercise induced hyperthermia.
    Towey C; Easton C; Simpson R; Pedlar C
    J Therm Biol; 2017 Jan; 63():124-130. PubMed ID: 28010810
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Gastrointestinal and Rectal Temperatures During Recovery After a Warm-Weather Road Race.
    Hosokawa Y; Adams WM; Stearns RL; Casa DJ
    J Athl Train; 2016 May; 51(5):382-8. PubMed ID: 27186918
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is Continuous Monitoring of Skin Surface Temperature a Reliable Proxy to Assess the Thermoregulatory Response in Endurance Horses During Field Exercise?
    Verdegaal EJMM; Howarth GS; McWhorter TJ; Delesalle CJG
    Front Vet Sci; 2022; 9():894146. PubMed ID: 35711810
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Factors affecting rectal temperature measurement using commonly available digital thermometers.
    Naylor JM; Streeter RM; Torgerson P
    Res Vet Sci; 2012 Feb; 92(1):121-3. PubMed ID: 21147490
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of a bandage or tendon boot on skin temperature of the metacarpus at rest and after exercise in horses.
    Westermann S; Windsteig V; Schramel JP; Peham C
    Am J Vet Res; 2014 Apr; 75(4):375-9. PubMed ID: 24669923
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noncontact infrared thermometer measurements offer a reasonable alternative to rectal temperature measurement in afebrile horses.
    Zobrist CN; Bishop RC; McCoy AM
    J Am Vet Med Assoc; 2024 Jun; 262(6):791-797. PubMed ID: 38467108
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Time following ingestion does not influence the validity of telemetry pill measurements of core temperature during exercise-heat stress: The journal
    Notley SR; Meade RD; Kenny GP
    Temperature (Austin); 2021; 8(1):12-20. PubMed ID: 33553501
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Core body temperature monitoring using the telemetric pill].
    Rav-Acha M; Heled Y; Slypher N; Moran DS
    Harefuah; 2003 Mar; 142(3):197-202, 238. PubMed ID: 12696474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.