These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 28657562)

  • 1. Patient specific instrumentation in total knee arthroplasty.
    Colombelli A; Belluati A; Rizqallah Y; Guerra G; Busatto C
    Acta Biomed; 2017 Jun; 88(2S):45-47. PubMed ID: 28657562
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.
    Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E
    Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.
    Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Component alignment and clinical outcome following total knee arthroplasty: a randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation.
    Huijbregts HJ; Khan RJ; Fick DP; Hall MJ; Punwar SA; Sorensen E; Reid MJ; Vedove SD; Haebich S
    Bone Joint J; 2016 Aug; 98-B(8):1043-9. PubMed ID: 27482015
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does the Preoperative Varus Deformity Influence the Survival of Postoperative Neutral-Aligned TKAs? An Analysis With a Minimum 5-Year Follow-Up.
    Oh SM; Bin SI; Kim JY; Cho HI; Lee BS; Kim JM
    J Arthroplasty; 2018 Oct; 33(10):3181-3185. PubMed ID: 29970326
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The difference between weight-bearing and non-weight-bearing alignment in patient-specific instrumentation planning.
    Paternostre F; Schwab PE; Thienpont E
    Knee Surg Sports Traumatol Arthrosc; 2014 Mar; 22(3):674-9. PubMed ID: 24051507
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT.
    Slevin O; Hirschmann A; Schiapparelli FF; Amsler F; Huegli RW; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1602-1609. PubMed ID: 29026941
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Patient specific instrumentation versus conventional knee arthroplasty: comparative study.
    Predescu V; Prescura C; Olaru R; Savin L; Botez P; Deleanu B
    Int Orthop; 2017 Jul; 41(7):1361-1367. PubMed ID: 27995304
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Slight under-correction following total knee arthroplasty for a valgus knee results in similar clinical outcomes.
    Lee SS; Lee H; Lee DH; Moon YW
    Arch Orthop Trauma Surg; 2018 Jul; 138(7):1011-1019. PubMed ID: 29770878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Mark Coventry Award: Custom Cutting Guides Do Not Improve Total Knee Arthroplasty Clinical Outcomes at 2 Years Followup.
    Nam D; Park A; Stambough JB; Johnson SR; Nunley RM; Barrack RL
    Clin Orthop Relat Res; 2016 Jan; 474(1):40-6. PubMed ID: 25712865
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Do varus or valgus outliers have higher forces in the medial or lateral compartments than those which are in-range after a kinematically aligned total knee arthroplasty? limb and joint line alignment after kinematically aligned total knee arthroplasty.
    Shelton TJ; Nedopil AJ; Howell SM; Hull ML
    Bone Joint J; 2017 Oct; 99-B(10):1319-1328. PubMed ID: 28963153
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Due to great variability fixed HKS angle for alignment of the distal cut leads to a significant error in coronal TKA orientation.
    Lampart M; Behrend H; Moser LB; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1434-1441. PubMed ID: 29961097
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of limb alignment and prosthetic orientation on patient-reported clinical outcomes in total knee arthroplasty.
    Kuroda Y; Takayama K; Ishida K; Hayashi S; Hashimoto S; Nishida K; Matsushita T; Niikura T; Kuroda R; Matsumoto T
    J Orthop Sci; 2019 Jul; 24(4):668-673. PubMed ID: 30553606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bone morphotypes of the varus and valgus knee.
    Thienpont E; Schwab PE; Cornu O; Bellemans J; Victor J
    Arch Orthop Trauma Surg; 2017 Mar; 137(3):393-400. PubMed ID: 28110363
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Patient-specific instrumentation does not improve alignment in total knee arthroplasty.
    Russell R; Brown T; Huo M; Jones R
    J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of conventional and patient-specific instruments in total knee arthroplasty.
    Daniilidis K; Tibesku CO
    Int Orthop; 2014 Mar; 38(3):503-8. PubMed ID: 23900384
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Remaining mild varus limb alignment leads to better clinical outcome in total knee arthroplasty for varus osteoarthritis.
    Nishida K; Matsumoto T; Takayama K; Ishida K; Nakano N; Matsushita T; Kuroda R; Kurosaka M
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3488-3494. PubMed ID: 27506810
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Under-corrected knees do not fail more than aligned knees at 8 years in fixed severe valgus total knee replacement.
    Boyer B; Pailhé R; Ramdane N; Eichler D; Remy F; Ehlinger M; Pasquier G
    Knee Surg Sports Traumatol Arthrosc; 2018 Nov; 26(11):3386-3394. PubMed ID: 29594324
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation.
    Schotanus MGM; Thijs E; Boonen B; Kerens B; Jong B; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1656-1661. PubMed ID: 28785788
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Frontal plane alignment after total knee arthroplasty using patient-specific instruments.
    Daniilidis K; Tibesku CO
    Int Orthop; 2013 Jan; 37(1):45-50. PubMed ID: 23232654
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]