These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

355 related articles for article (PubMed ID: 28658505)

  • 1. Fast kVp-switching dual energy contrast-enhanced thorax and cardiac CT: A phantom study on the accuracy of iodine concentration and effective atomic number measurement.
    Papadakis AE; Damilakis J
    Med Phys; 2017 Sep; 44(9):4724-4735. PubMed ID: 28658505
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of electron density, effective atomic number, and iodine concentration determination with a dual-layer dual-energy computed tomography system.
    Hua CH; Shapira N; Merchant TE; Klahr P; Yagil Y
    Med Phys; 2018 Jun; 45(6):2486-2497. PubMed ID: 29624708
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners.
    Almeida IP; Schyns LE; Öllers MC; van Elmpt W; Parodi K; Landry G; Verhaegen F
    Med Phys; 2017 Jan; 44(1):171-179. PubMed ID: 28070917
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of the raw-data-based effective atomic numbers and monochromatic CT numbers for contrast medium with a dual-energy CT technique.
    Kawahara D; Ozawa S; Yokomachi K; Tanaka S; Higaki T; Fujioka C; Suzuki T; Tsuneda M; Nakashima T; Ohno Y; Nagata Y
    Br J Radiol; 2018 Feb; 91(1082):20170524. PubMed ID: 29161881
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Deriving effective atomic numbers from DECT based on a parameterization of the ratio of high and low linear attenuation coefficients.
    Landry G; Seco J; Gaudreault M; Verhaegen F
    Phys Med Biol; 2013 Oct; 58(19):6851-66. PubMed ID: 24025623
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system.
    Nute JL; Jacobsen MC; Stefan W; Wei W; Cody DD
    Med Phys; 2018 Apr; 45(4):1444-1458. PubMed ID: 29446082
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Synthesized effective atomic numbers for commercially available dual-energy CT.
    Kawahara D; Ozawa S; Yokomachi K; Fujioka C; Kimura T; Awai K; Nagata Y
    Rep Pract Oncol Radiother; 2020; 25(4):692-697. PubMed ID: 32684854
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual energy CT of the chest: how about the dose?
    Schenzle JC; Sommer WH; Neumaier K; Michalski G; Lechel U; Nikolaou K; Becker CR; Reiser MF; Johnson TR
    Invest Radiol; 2010 Jun; 45(6):347-53. PubMed ID: 20404737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT.
    Matsumoto K; Jinzaki M; Tanami Y; Ueno A; Yamada M; Kuribayashi S
    Radiology; 2011 Apr; 259(1):257-62. PubMed ID: 21330561
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy and reproducibility of effective atomic number and electron density measurements from sequential dual energy CT.
    Schaeffer CJ; Leon SM; Olguin CA; Arreola MM
    Med Phys; 2021 Jul; 48(7):3525-3539. PubMed ID: 33932301
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.
    So A; Imai Y; Nett B; Jackson J; Nett L; Hsieh J; Wisenberg G; Teefy P; Yadegari A; Islam A; Lee TY
    Med Phys; 2016 Aug; 43(8):4821. PubMed ID: 27487900
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of x-ray tube parameters and iodine concentration on image quality and radiation dose in cerebral pediatric and adult CT angiography: a phantom study.
    Papadakis AE; Perisinakis K; Raissaki M; Damilakis J
    Invest Radiol; 2013 Apr; 48(4):192-9. PubMed ID: 23344518
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interventional dual-energy imaging-Feasibility of rapid kV-switching on a C-arm CT system.
    Müller K; Datta S; Ahmad M; Choi JH; Moore T; Pung L; Niebler C; Gold GE; Maier A; Fahrig R
    Med Phys; 2016 Oct; 43(10):5537. PubMed ID: 27782692
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dual-source photon counting detector CT with a tin filter: a phantom study on iodine quantification performance.
    Tao A; Huang R; Tao S; Michalak GJ; McCollough CH; Leng S
    Phys Med Biol; 2019 May; 64(11):115019. PubMed ID: 31018197
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Realistic Kidney Tissue Surrogates for Multienergy Computed Tomography-Feasibility and Estimation of Energy-Dependent Attenuation Thresholds for Renal Lesion Enhancement in Low-kV and Virtual Monoenergetic Imaging.
    Euler A; Zadory M; Breiding PS; Sartoretti T; Ghafoor S; Froehlich JM; Donati OF
    Invest Radiol; 2021 Dec; 56(12):791-798. PubMed ID: 33899757
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency.
    Krauss B; Grant KL; Schmidt BT; Flohr TG
    Invest Radiol; 2015 Feb; 50(2):114-8. PubMed ID: 25373305
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of heart rate, vessel angulation and acquisition protocol on the estimation accuracy of calcified artery stenosis in dual energy cardiac CT: A phantom study.
    Papadakis AE; Perisinakis K; Damilakis J
    Phys Med; 2020 Feb; 70():208-215. PubMed ID: 32058923
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner.
    Goodsitt MM; Christodoulou EG; Larson SC
    Med Phys; 2011 Apr; 38(4):2222-32. PubMed ID: 21626956
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Iodine quantification using dual-energy multidetector computed tomography imaging: phantom study assessing the impact of iterative reconstruction schemes and patient habitus on accuracy.
    Feuerlein S; Heye TJ; Bashir MR; Boll DT
    Invest Radiol; 2012 Nov; 47(11):656-61. PubMed ID: 22996313
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical Note: Quantitative accuracy evaluation for spectral images from a detector-based spectral CT scanner using an iodine phantom.
    Duan X; Arbique G; Guild J; Xi Y; Anderson J
    Med Phys; 2018 May; 45(5):2048-2053. PubMed ID: 29479712
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.