  • 1. A review of the atrial upper rate algorithms of St. Jude Medical (Abbott) cardiac implantable electronic devices : Incidence of repetitive nonreentrant ventriculoatrial synchrony (RNRVAS).
    Barold SS
    Herzschrittmacherther Elektrophysiol; 2017 Sep; 28(3):320-327. PubMed ID: 28660476
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Repetitive nonreentrant ventriculoatrial synchrony: An underrecognized cause of pacemaker-related arrhythmia.
    Sharma PS; Kaszala K; Tan AY; Koneru JN; Shepard R; Ellenbogen KA; Huizar JF
    Heart Rhythm; 2016 Aug; 13(8):1739-47. PubMed ID: 27050909
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Potential triggering of repetitive nonreentrant ventriculoatrial synchrony by loss of atrial capture.
    Atar AI; Atar I
    Ann Noninvasive Electrocardiol; 2023 Jan; 28(1):e13033. PubMed ID: 36534029
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Novel Pacemaker-Mediated Arrhythmia Without Ventriculoatrial Conduction Can Induce Atrial Fibrillation.
    Gjermeni E; Doering M; Richter S; Hindricks G; Bode K
    JACC Clin Electrophysiol; 2021 Jan; 7(1):1-5. PubMed ID: 33478700
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pseudo repetitive non-reentrant ventriculoatrial synchrony: Current challenges.
    Gjermeni E; Doering M; Hindricks G; Bode K
    Pacing Clin Electrophysiol; 2023 Jun; 46(6):467-474. PubMed ID: 36635217
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pacemaker repetitive nonreentrant ventriculoatrial synchrony. Why did automatic mode switching occur?
    Barold SS; Stroobandt RX; Van Heuverswyn F
    J Electrocardiol; 2012; 45(4):420-425. PubMed ID: 22560600
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Functional atrial undersensing associated with switching to a tracking mode of pacing.
    Barold SS; Van Heuverswyn F; Timmers L; Stroobandt RX
    Pacing Clin Electrophysiol; 2012 Oct; 35(10):1188-93. PubMed ID: 22816428
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic mode switching of a dual chamber implantable cardioverter-defibrillator induced by a ventricular escape rhythm.
    Barold SS; Van Heuverswyn F; Stroobandt RX
    J Electrocardiol; 2013; 46(2):136-9. PubMed ID: 23399053
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Proarrhythmic effects from competitive atrial pacing and potential programming solutions.
    Wass SY; Kanj M; Mayuga K; Hussein A; Saliba WI; Bhargava M; Cantillon D; Tchou PJ; Wazni O; Wilkoff BL; Chung MK
    Pacing Clin Electrophysiol; 2020 Jul; 43(7):720-729. PubMed ID: 32452039
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is automatic mode switching effective for atrial arrhythmias occurring at different rates? A study of the efficacy of automatic mode and rate switching to simulated atrial arrhythmias by chest wall stimulation.
    Leung SK; Lau CP; Lam CT; Tse HF; Lee K; Chan WK; Leung Z
    Pacing Clin Electrophysiol; 2000 May; 23(5):824-31. PubMed ID: 10833701
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pacemaker repetitive nonreentrant ventriculoatrial synchronous rhythm. A review.
    Barold SS; Levine PA
    J Interv Card Electrophysiol; 2001 Mar; 5(1):45-58. PubMed ID: 11248774
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Atrial lead malfunction presenting as new onset pacemaker-mediated tachycardia.
    Barold SS; Stroobandt RX
    Europace; 2012 Jul; 14(7):1060-1. PubMed ID: 22286204
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Case of a Cardiac Resynchronization Therapy-Defibrillator Exhibiting a Lower and Alternately Variable Basic Rate.
    Iwazaki K; Kojima T; Murasawa T; Yokota J; Tanimoto H; Matsuda J; Fukuma N; Matsubara T; Shimizu Y; Oguri G; Hasumi E; Kubo H; Chang K; Fujiu K; Komuro I
    Int Heart J; 2018 May; 59(3):626-629. PubMed ID: 29628471
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Case report: complex arrhythmia induced by noncompetitive atrial pacing algorithm of DDDR pacemaker.
    Barold SS; Levine PA; Isaeff DM; Betzold R
    J Interv Card Electrophysiol; 2001 Dec; 5(4):431-4. PubMed ID: 11752911
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automatic mode switching of implantable pacemakers: II. Clinical performance of current algorithms and their programming.
    Lau CP; Leung SK; Tse HF; Barold SS
    Pacing Clin Electrophysiol; 2002 Jul; 25(7):1094-113. PubMed ID: 12164453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel findings of an old algorithm: PVC response "Atrial Pace'' initiates atrial arrhythmias in Abbott ICD and CRT-D devices.
    Sane M; Marjamaa A; Kuusisto J; Raatikainen P; Karvonen J
    Pacing Clin Electrophysiol; 2023 Feb; 46(2):125-131. PubMed ID: 36402455
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stroke incidence in patients with cardiac implantable electronic devices remotely controlled with automatic alerts of atrial fibrillation. A sub-analysis of the HomeGuide study.
    Ricci RP; Vaccari D; Morichelli L; Zanotto G; Calò L; D'Onofrio A; Curnis A; Pisanò EC; Nangah R; Brieda M; Calzolari V; Melissano D; Rovai N; Gargaro A
    Int J Cardiol; 2016 Sep; 219():251-6. PubMed ID: 27340918
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of varying atrial sensitivity, AV interval, and detection algorithm on automatic mode switching.
    Palma EC; Kedarnath V; Vankawalla V; Andrews CA; Hanson S; Furman S; Gross JN
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1735-9. PubMed ID: 9045215
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Automatic mode switching of implantable pacemakers: I. Principles of instrumentation, clinical, and hemodynamic considerations.
    Lau CP; Leung SK; Tse HF; Barold SS
    Pacing Clin Electrophysiol; 2002 Jun; 25(6):967-83. PubMed ID: 12137350
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Troubleshooting Pacemaker Behavior: Consequence of Prolonged Ventriculoatrial Conduction.
    Dhir SK; Gould GE; Joliff JL
    J Innov Card Rhythm Manag; 2020 Sep; 11(9):4246-4249. PubMed ID: 32983594
    [TBL] [Abstract][Full Text] [Related]  