These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 28667965)

  • 1. Coaxial CVD diamond detector for neutron diagnostics at ShenGuang III laser facility.
    Yu B; Liu S; Chen Z; Huang T; Jiang W; Chen B; Pu Y; Yan J; Zhang X; Song Z; Tang Q; Hou L; Ding Y; Zheng J
    Rev Sci Instrum; 2017 Jun; 88(6):063506. PubMed ID: 28667965
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Response measurement of single-crystal chemical vapor deposition diamond radiation detector for intense X-rays aiming at neutron bang-time and neutron burn-history measurement on an inertial confinement fusion with fast ignition.
    Shimaoka T; Kaneko JH; Arikawa Y; Isobe M; Sato Y; Tsubota M; Nagai T; Kojima S; Abe Y; Sakata S; Fujioka S; Nakai M; Shiraga H; Azechi H; Chayahara A; Umezawa H; Shikata S
    Rev Sci Instrum; 2015 May; 86(5):053503. PubMed ID: 26026521
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel photomultiplier tube neutron time-of-flight detector.
    Glebov VY; Stoeckl C; Forrest CJ; Knauer JP; Mannion OM; Romanofsky MH; Sangster TC; Regan SP
    Rev Sci Instrum; 2021 Jan; 92(1):013509. PubMed ID: 33514216
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Using x-rays to test chemical vapor deposited diamond detectors for areal density measurement at the National Ignition Facility.
    Dauffy LS; Koch JA; Tommasini R; Izumi N
    Rev Sci Instrum; 2008 Oct; 79(10):10E931. PubMed ID: 19044586
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility.
    Kabadi NV; Sio H; Glebov V; Gatu Johnson M; MacPhee A; Frenje JA; Li CK; Seguin F; Petrasso R; Forrest C; Knauer J; Rinderknecht HG
    Rev Sci Instrum; 2016 Nov; 87(11):11D817. PubMed ID: 27910431
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Down-scattered neutron imaging detector for areal density measurement of inertial confinement fusion.
    Arikawa Y; Yamanoi K; Nakazato T; Estacio ES; Shimizu T; Sarukura N; Nakai M; Hosoda H; Norimatsu T; Hironaka Y; Azechi H; Izumi N; Murata T; Fujino S; Yoshida H; Kamada K; Usuki Y; Suyama T; Yoshikawa A; Satoh N; Kan H
    Rev Sci Instrum; 2010 Oct; 81(10):10D303. PubMed ID: 21033829
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous measurement of energy spectrum and fluence of neutrons using a diamond detector.
    Liu J; Jiang H; Cui Z; Hu Y; Bai H; Fan T; Chen J; Gao Y; Yang X; Zhang G
    Sci Rep; 2022 Jul; 12(1):12022. PubMed ID: 35835805
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The National Ignition Facility neutron time-of-flight system and its initial performance (invited).
    Glebov VY; Sangster TC; Stoeckl C; Knauer JP; Theobald W; Marshall KL; Shoup MJ; Buczek T; Cruz M; Duffy T; Romanofsky M; Fox M; Pruyne A; Moran MJ; Lerche RA; McNaney J; Kilkenny JD; Eckart MJ; Schneider D; Munro D; Stoeffl W; Zacharias R; Haslam JJ; Clancy T; Yeoman M; Warwas D; Horsfield CJ; Bourgade JL; Landoas O; Disdier L; Chandler GA; Leeper RJ
    Rev Sci Instrum; 2010 Oct; 81(10):10D325. PubMed ID: 21033848
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility.
    Glebov VY; Forrest CJ; Kendrick J; Knauer JP; Mannion OM; McClow H; Regan SP; Stoeckl C; Stanley B; Theobald W
    Rev Sci Instrum; 2022 Sep; 93(9):093522. PubMed ID: 36182446
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Absolute calibration method for laser megajoule neutron yield measurement by activation diagnostics.
    Landoas O; Glebov VY; Rossé B; Briat M; Disdier L; Sangster TC; Duffy T; Marmouget JG; Varignon C; Ledoux X; Caillaud T; Thfoin I; Bourgade JL
    Rev Sci Instrum; 2011 Jul; 82(7):073501. PubMed ID: 21806179
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A neutron time-of-flight system for inertial confinement fusion.
    Tang Q; Chen J; Xiao Y; Yi T; Liu Z; Zhan X; Song Z
    Rev Sci Instrum; 2020 Feb; 91(2):023508. PubMed ID: 32113434
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Thermal and fast neutron detection through high-purity single-crystal CVD diamonds.
    Lee CY; Ban CM; Lee HR; Choo KN; Jun BH
    Appl Radiat Isot; 2019 Oct; 152():25-29. PubMed ID: 31279150
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibration of a neutron time-of-flight detector with a rapid instrument response function for measurements of bulk fluid motion on OMEGA.
    Mannion OM; Glebov VY; Forrest CJ; Knauer JP; Goncharov VN; Regan SP; Sangster TC; Stoeckl C; Gatu Johnson M
    Rev Sci Instrum; 2018 Oct; 89(10):10I131. PubMed ID: 30399681
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A gated liquid-scintillator-based neutron detector for fast-ignitor experiments and down-scattered neutron measurements.
    Stoeckl C; Cruz M; Glebov VY; Knauer JP; Lauck R; Marshall K; Mileham C; Sangster TC; Theobald W
    Rev Sci Instrum; 2010 Oct; 81(10):10D302. PubMed ID: 21033828
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Neutron temporal diagnostic for high-yield deuterium-tritium cryogenic implosions on OMEGA.
    Stoeckl C; Boni R; Ehrne F; Forrest CJ; Glebov VY; Katz J; Lonobile DJ; Magoon J; Regan SP; Shoup MJ; Sorce A; Sorce C; Sangster TC; Weiner D
    Rev Sci Instrum; 2016 May; 87(5):053501. PubMed ID: 27250417
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Note: neutron bang time diagnostic system on Shenguang-III prototype.
    Tang Q; Chen J; Liu Z; Zhan X; Song Z
    Rev Sci Instrum; 2014 Apr; 85(4):046108. PubMed ID: 24784686
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited).
    Murari A; Angelone M; Bonheure G; Cecil E; Craciunescu T; Darrow D; Edlington T; Ericsson G; Gatu-Johnson M; Gorini G; Hellesen C; Kiptily V; Mlynar J; Perez von Thun C; Pillon M; Popovichev S; Syme B; Tardocchi M; Zoita VL;
    Rev Sci Instrum; 2010 Oct; 81(10):10E136. PubMed ID: 21061488
    [TBL] [Abstract][Full Text] [Related]  

  • 18. CVD diamond detector with interdigitated electrode pattern for time-of-flight energy-loss measurements of low-energy ion bunches.
    Cayzac W; Pomorski M; Blažević A; Canaud B; Deslandes D; Fariaut J; Gontier D; Lescoute E; Marmouget JG; Occelli F; Oudot G; Reverdin C; Sauvestre JE; Sollier A; Soullié G; Varignon C; Villette B
    Rev Sci Instrum; 2018 May; 89(5):053301. PubMed ID: 29864825
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A fused silica Cherenkov radiator for high precision time-of-flight measurement of DT
    Moore AS; Schlossberg DJ; Hartouni EP; Sayre D; Eckart MJ; Hatarik R; Barbosa F; Root J; Waltz C; Beeman B; Rubery MS; Grim GP
    Rev Sci Instrum; 2018 Oct; 89(10):10I120. PubMed ID: 30399816
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ion temperature measurements of indirect-drive implosions with the neutron time-of-flight detector on SG-III laser facility.
    Chen Z; Zhang X; Pu Y; Yan J; Huang T; Jiang W; Yu B; Chen B; Tang Q; Song Z; Chen J; Zhan X; Liu Z; Xie X; Jiang S; Liu S
    Rev Sci Instrum; 2018 Feb; 89(2):023504. PubMed ID: 29495861
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.