These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 28667968)

  • 1. Fast x-ray detector system with simultaneous measurement of timing and energy for a single photon.
    Masuda T; Okubo S; Hara H; Hiraki T; Kitao S; Miyamoto Y; Okai K; Ozaki R; Sasao N; Seto M; Uetake S; Yamaguchi A; Yoda Y; Yoshimi A; Yoshimura K
    Rev Sci Instrum; 2017 Jun; 88(6):063105. PubMed ID: 28667968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nuclear resonant scattering measurements on (57)Fe by multichannel scaling with a 64-pixel silicon avalanche photodiode linear-array detector.
    Kishimoto S; Mitsui T; Haruki R; Yoda Y; Taniguchi T; Shimazaki S; Ikeno M; Saito M; Tanaka M
    Rev Sci Instrum; 2014 Nov; 85(11):113102. PubMed ID: 25430093
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements.
    Bao Z; Zhang Y; Jiang J; Ma Y; Liu Y; Li S; Zhang H; Liu M; Zhou Y; Li Z; Liu Y; Li H; Shen Z; Yu C; Shi Z; Ou Z; Zhou A; Li Q; Liu P; Xu W; Hu MY; Zhao J; Alp EE
    Rev Sci Instrum; 2023 Oct; 94(10):. PubMed ID: 37877791
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Avalanche Photodiodes as Fast X-ray Detectors.
    Kishimoto S
    J Synchrotron Radiat; 1998 May; 5(Pt 3):275-9. PubMed ID: 15263491
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Time-Resolved XEOL Experiment System on BL14W1 at SSRF].
    Zhang ZH; Jiang Z; Xue S; Zheng LF
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Aug; 35(8):2324-8. PubMed ID: 26672318
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Note: Large active area solid state photon counter with 20 ps timing resolution and 60 fs detection delay stability.
    Prochazka I; Kodet J; Eckl J; Blazej J
    Rev Sci Instrum; 2017 Oct; 88(10):106105. PubMed ID: 29092507
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of energy response for photon-counting detectors using x-ray fluorescence.
    Ding H; Cho HM; Barber WC; Iwanczyk JS; Molloi S
    Med Phys; 2014 Dec; 41(12):121902. PubMed ID: 25471962
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulse-height measurements with a cooled avalanche-photodiode detector.
    Kishimoto S
    J Synchrotron Radiat; 1998 May; 5(Pt 3):883-5. PubMed ID: 15263685
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Geiger-mode APDs for PET block detector designs.
    Kolb A; Lorenz E; Judenhofer MS; Renker D; Lankes K; Pichler BJ
    Phys Med Biol; 2010 Apr; 55(7):1815-32. PubMed ID: 20208095
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.
    Yeom JY; Vinke R; Levin CS
    Med Phys; 2014 Dec; 41(12):122501. PubMed ID: 25471979
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
    Habte F; Foudray AM; Olcott PD; Levin CS
    Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
    [TBL] [Abstract][Full Text] [Related]  

  • 12. X-ray characterization of a multichannel smart-pixel array detector.
    Ross S; Haji-Sheikh M; Huntington A; Kline D; Lee A; Li Y; Rhee J; Tarpley M; Walko DA; Westberg G; Williams G; Zou H; Landahl E
    J Synchrotron Radiat; 2016 Jan; 23(1):196-205. PubMed ID: 26698064
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.
    Shikhaliev PM
    Phys Med Biol; 2006 Sep; 51(17):4267-87. PubMed ID: 16912381
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel flat-response x-ray detector in the photon energy range of 0.1-4 keV.
    Li Z; Jiang X; Liu S; Huang T; Zheng J; Yang J; Li S; Guo L; Zhao X; Du H; Song T; Yi R; Liu Y; Jiang S; Ding Y
    Rev Sci Instrum; 2010 Jul; 81(7):073504. PubMed ID: 20687719
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Silicon avalanche photodiodes for direct detection of X-rays.
    Baron AQ; Kishimoto S; Morse J; Rigal JM
    J Synchrotron Radiat; 2006 Mar; 13(Pt 2):131-42. PubMed ID: 16495613
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The first microbeam synchrotron X-ray fluorescence beamline at the Siam Photon Laboratory.
    Tancharakorn S; Tanthanuch W; Kamonsutthipaijit N; Wongprachanukul N; Sophon M; Chaichuay S; Uthaisar C; Yimnirun R
    J Synchrotron Radiat; 2012 Jul; 19(Pt 4):536-40. PubMed ID: 22713886
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of a pnCCD in X-ray diffraction: a three-dimensional X-ray detector.
    Leitenberger W; Hartmann R; Pietsch U; Andritschke R; Starke I; Strüder L
    J Synchrotron Radiat; 2008 Sep; 15(Pt 5):449-57. PubMed ID: 18728315
    [TBL] [Abstract][Full Text] [Related]  

  • 18. D2AM, a beamline with a high-intensity point-focusing fixed-exit monochromator for multiwavelength anomalous diffraction experiments.
    Ferrer JL; Simon JP; Bérar JF; Caillot B; Fanchon E; Kaïkati O; Arnaud S; Guidotti M; Pirocchi M; Roth M
    J Synchrotron Radiat; 1998 Nov; 5(Pt 6):1346-56. PubMed ID: 16687847
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.
    Barber WC; Wessel JC; Nygard E; Iwanczyk JS
    Nucl Instrum Methods Phys Res A; 2015 Jun; 784():531-537. PubMed ID: 25937684
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response.
    Troussel P; Villette B; Emprin B; Oudot G; Tassin V; Bridou F; Delmotte F; Krumrey M
    Rev Sci Instrum; 2014 Jan; 85(1):013503. PubMed ID: 24517761
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.