These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 28678818)

  • 1. Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study.
    Scharf M; Brendel S; Melzer K; Hentschke C; May M; Uder M; Lell MM
    PLoS One; 2017; 12(7):e0180302. PubMed ID: 28678818
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intraindividual comparison of diagnostic performance in patients with hepatic metastasis of full-dose standard and half-dose iterative reconstructions with dual-source abdominal computed tomography.
    Park M; Chung YE; Lee HS; Choi JY; Park MS; Kim MJ; Kim KW
    Invest Radiol; 2014 Apr; 49(4):195-200. PubMed ID: 24300843
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sinogram-affirmed iterative reconstruction of low-dose chest CT: effect on image quality and radiation dose.
    Kalra MK; Woisetschläger M; Dahlström N; Singh S; Digumarthy S; Do S; Pien H; Quick P; Schmidt B; Sedlmair M; Shepard JA; Persson A
    AJR Am J Roentgenol; 2013 Aug; 201(2):W235-44. PubMed ID: 23883238
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography.
    Kalra MK; Woisetschläger M; Dahlström N; Singh S; Lindblom M; Choy G; Quick P; Schmidt B; Sedlmair M; Blake MA; Persson A
    J Comput Assist Tomogr; 2012; 36(3):339-46. PubMed ID: 22592621
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical evaluation and potential radiation dose reduction of the novel sinogram-affirmed iterative reconstruction technique (SAFIRE) in abdominal computed tomography angiography.
    Schabel C; Fenchel M; Schmidt B; Flohr TG; Wuerslin C; Thomas C; Korn A; Tsiflikas I; Claussen CD; Heuschmid M; Ketelsen D
    Acad Radiol; 2013 Feb; 20(2):165-72. PubMed ID: 23099242
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low tube voltage intermediate tube current liver MDCT: sinogram-affirmed iterative reconstruction algorithm for detection of hypervascular hepatocellular carcinoma.
    Yu MH; Lee JM; Yoon JH; Baek JH; Han JK; Choi BI; Flohr TG
    AJR Am J Roentgenol; 2013 Jul; 201(1):23-32. PubMed ID: 23789655
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sinogram affirmed iterative reconstruction in head CT: improvement of objective and subjective image quality with concomitant radiation dose reduction.
    Korn A; Bender B; Fenchel M; Spira D; Schabel C; Thomas C; Flohr T; Claussen CD; Bhadelia R; Ernemann U; Brodoefel H
    Eur J Radiol; 2013 Sep; 82(9):1431-5. PubMed ID: 23587902
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Can sinogram-affirmed iterative (SAFIRE) reconstruction improve imaging quality on low-dose lung CT screening compared with traditional filtered back projection (FBP) reconstruction?
    Yang WJ; Yan FH; Liu B; Pang LF; Hou L; Zhang H; Pan ZL; Chen KM
    J Comput Assist Tomogr; 2013; 37(2):301-5. PubMed ID: 23493224
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Physician preference between low-dose computed tomography with a sinogram-affirmed iterative reconstruction algorithm and routine-dose computed tomography with filtered back projection in abdominopelvic imaging.
    Hardie AD; Tipnis SV; Rieter WJ; Rissing MS; De Cecco CN
    J Comput Assist Tomogr; 2013; 37(6):932-6. PubMed ID: 24270115
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography.
    May MS; Wüst W; Brand M; Stahl C; Allmendinger T; Schmidt B; Uder M; Lell MM
    Invest Radiol; 2011 Jul; 46(7):465-70. PubMed ID: 21467948
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*).
    Choy S; Parhar D; Lian K; Schmiedeskamp H; Louis L; O'Connell T; McLaughlin P; Nicolaou S
    Abdom Radiol (NY); 2019 Jan; 44(1):355-361. PubMed ID: 29980828
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique.
    Kim JH; Kim MJ; Kim HY; Lee MJ
    Clin Imaging; 2014; 38(5):710-4. PubMed ID: 24984841
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diagnostic Accuracy of CT Enterography for Active Inflammatory Terminal Ileal Crohn Disease: Comparison of Full-Dose and Half-Dose Images Reconstructed with FBP and Half-Dose Images with SAFIRE.
    Gandhi NS; Baker ME; Goenka AH; Bullen JA; Obuchowski NA; Remer EM; Coppa CP; Einstein D; Feldman MK; Kanmaniraja D; Purysko AS; Vahdat N; Primak AN; Karim W; Herts BR
    Radiology; 2016 Aug; 280(2):436-45. PubMed ID: 27077382
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dose reduction in computed tomography of the chest: image quality of iterative reconstructions at a 50% radiation dose compared to filtered back projection at a 100% radiation dose.
    May MS; Eller A; Stahl C; Wuest W; Scharf M; Hammon M; Dankerl P; Schlechtweg PM; Allmendinger T; Sedlmair M; Schmidt B; Uder M; Lell MM
    Rofo; 2014 Jun; 186(6):576-84. PubMed ID: 24477504
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Raw-data-based iterative reconstruction versus filtered back projection: image quality of low-dose chest computed tomography examinations in 87 patients.
    Wang H; Tan B; Zhao B; Liang C; Xu Z
    Clin Imaging; 2013; 37(6):1024-32. PubMed ID: 23916244
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential.
    Winklehner A; Karlo C; Puippe G; Schmidt B; Flohr T; Goetti R; Pfammatter T; Frauenfelder T; Alkadhi H
    Eur Radiol; 2011 Dec; 21(12):2521-6. PubMed ID: 21822785
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction.
    Nakamoto A; Kim T; Hori M; Onishi H; Tsuboyama T; Sakane M; Tatsumi M; Tomiyama N
    Eur J Radiol; 2015 Sep; 84(9):1715-23. PubMed ID: 26037266
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low-dose chest computed tomography with sinogram-affirmed iterative reconstruction, iterative reconstruction in image space, and filtered back projection: studies on image quality.
    Hwang HJ; Seo JB; Lee HJ; Lee SM; Kim EY; Oh SY; Kim JE
    J Comput Assist Tomogr; 2013; 37(4):610-7. PubMed ID: 23863540
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultra-low dose abdominal MDCT: using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study.
    Khawaja RDA; Singh S; Blake M; Harisinghani M; Choy G; Karosmangulu A; Padole A; Do S; Brown K; Thompson R; Morton T; Raihani N; Koehler T; Kalra MK
    Eur J Radiol; 2015 Jan; 84(1):2-10. PubMed ID: 25458225
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnostic accuracy of coronary CT angiography: comparison of filtered back projection and iterative reconstruction with different strengths.
    Wang R; Schoepf UJ; Wu R; Nance JW; Lv B; Yang H; Li F; Lu D; Zhang Z
    J Comput Assist Tomogr; 2014; 38(2):179-84. PubMed ID: 24625599
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.