These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
407 related articles for article (PubMed ID: 28681976)
1. Mixed integer programming with dose-volume constraints in intensity-modulated proton therapy. Zhang P; Fan N; Shan J; Schild SE; Bues M; Liu W J Appl Clin Med Phys; 2017 Sep; 18(5):29-35. PubMed ID: 28681976 [TBL] [Abstract][Full Text] [Related]
2. Robust treatment planning with conditional value at risk chance constraints in intensity-modulated proton therapy. An Y; Liang J; Schild SE; Bues M; Liu W Med Phys; 2017 Jan; 44(1):28-36. PubMed ID: 28044325 [TBL] [Abstract][Full Text] [Related]
3. Robust intensity-modulated proton therapy to reduce high linear energy transfer in organs at risk. An Y; Shan J; Patel SH; Wong W; Schild SE; Ding X; Bues M; Liu W Med Phys; 2017 Dec; 44(12):6138-6147. PubMed ID: 28976574 [TBL] [Abstract][Full Text] [Related]
4. Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy. Lee EK; Fox T; Crocker I Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):301-20. PubMed ID: 16289912 [TBL] [Abstract][Full Text] [Related]
5. Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer. Liu C; Schild SE; Chang JY; Liao Z; Korte S; Shen J; Ding X; Hu Y; Kang Y; Keole SR; Sio TT; Wong WW; Sahoo N; Bues M; Liu W Int J Radiat Oncol Biol Phys; 2018 Jun; 101(2):479-489. PubMed ID: 29550033 [TBL] [Abstract][Full Text] [Related]
6. Comparison of linear and nonlinear programming approaches for "worst case dose" and "minmax" robust optimization of intensity-modulated proton therapy dose distributions. Zaghian M; Cao W; Liu W; Kardar L; Randeniya S; Mohan R; Lim G J Appl Clin Med Phys; 2017 Mar; 18(2):15-25. PubMed ID: 28300378 [TBL] [Abstract][Full Text] [Related]
7. Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small-spot intensity-modulated proton versus volumetric-modulated arc therapies. Liu C; Bhangoo RS; Sio TT; Yu NY; Shan J; Chiang JS; Ding JX; Rule WG; Korte S; Lara P; Ding X; Bues M; Hu Y; DeWees T; Ashman JB; Liu W J Appl Clin Med Phys; 2019 Jul; 20(7):15-27. PubMed ID: 31112371 [TBL] [Abstract][Full Text] [Related]
8. Helical tomotherapy and intensity modulated proton therapy in the treatment of dominant intraprostatic lesion: a treament planning comparison. Fellin F; Azzeroni R; Maggio A; Lorentini S; Cozzarini C; Di Muzio N; Fiorino C; Calandrino R; Schwarz M Radiother Oncol; 2013 May; 107(2):207-12. PubMed ID: 23541644 [TBL] [Abstract][Full Text] [Related]
9. Intensity modulated proton therapy for craniospinal irradiation: organ-at-risk exposure and a low-gradient junctioning technique. Stoker JB; Grant J; Zhu XR; Pidikiti R; Mahajan A; Grosshans DR Int J Radiat Oncol Biol Phys; 2014 Nov; 90(3):637-44. PubMed ID: 25194667 [TBL] [Abstract][Full Text] [Related]
10. Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer. Rana S; Zheng Y J Appl Clin Med Phys; 2015 Sep; 16(5):447–456. PubMed ID: 26699310 [TBL] [Abstract][Full Text] [Related]
11. Use of single-energy proton pencil beam scanning Bragg peak for intensity-modulated proton therapy FLASH treatment planning in liver-hypofractionated radiation therapy. Wei S; Lin H; Shi C; Xiong W; Chen CC; Huang S; Press RH; Hasan S; Chhabra AM; Choi JI; Simone CB; Kang M Med Phys; 2022 Oct; 49(10):6560-6574. PubMed ID: 35929404 [TBL] [Abstract][Full Text] [Related]
12. Small-spot intensity-modulated proton therapy and volumetric-modulated arc therapies for patients with locally advanced non-small-cell lung cancer: A dosimetric comparative study. Liu C; Sio TT; Deng W; Shan J; Daniels TB; Rule WG; Lara PR; Korte SM; Shen J; Ding X; Schild SE; Bues M; Liu W J Appl Clin Med Phys; 2018 Nov; 19(6):140-148. PubMed ID: 30328674 [TBL] [Abstract][Full Text] [Related]
13. Lower doses to hippocampi and other brain structures for skull-base meningiomas with intensity modulated proton therapy compared to photon therapy. Florijn MA; Sharfo AWM; Wiggenraad RGJ; van Santvoort JPC; Petoukhova AL; Hoogeman MS; Mast ME; Dirkx MLP Radiother Oncol; 2020 Jan; 142():147-153. PubMed ID: 31522879 [TBL] [Abstract][Full Text] [Related]
14. The feasibility of dose escalation using intensity-modulated radiotherapy (IMRT) and intensity-modulated proton therapy (IMPT) with FDG PET/CT guided in esophageal cancer. Zhang Y; Fan B; Sun T; Xu J; Yin Y; Chen Z; Zhu J; Yu J; Hu M J Cancer Res Ther; 2022 Sep; 18(5):1261-1267. PubMed ID: 36204871 [TBL] [Abstract][Full Text] [Related]
15. A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy. Shan J; Sio TT; Liu C; Schild SE; Bues M; Liu W Med Phys; 2019 Jan; 46(1):382-393. PubMed ID: 30387870 [TBL] [Abstract][Full Text] [Related]
16. Per-voxel constraints to minimize hot spots in linear energy transfer-guided robust optimization for base of skull head and neck cancer patients in IMPT. Feng H; Shan J; Anderson JD; Wong WW; Schild SE; Foote RL; Patrick CL; Tinnon KB; Fatyga M; Bues M; Patel SH; Liu W Med Phys; 2022 Jan; 49(1):632-647. PubMed ID: 34843119 [TBL] [Abstract][Full Text] [Related]
17. Feasibility of automated proton therapy plan adaptation for head and neck tumors using cone beam CT images. Kurz C; Nijhuis R; Reiner M; Ganswindt U; Thieke C; Belka C; Parodi K; Landry G Radiat Oncol; 2016 Apr; 11():64. PubMed ID: 27129305 [TBL] [Abstract][Full Text] [Related]
18. Validation of Fully Automated Robust Multicriterial Treatment Planning for Head and Neck Cancer IMPT. Huiskes M; Kong W; Oud M; Crama K; Rasch C; Breedveld S; Heijmen B; Astreinidou E Int J Radiat Oncol Biol Phys; 2024 Jul; 119(3):968-977. PubMed ID: 38284961 [TBL] [Abstract][Full Text] [Related]
19. Dosimetric comparison of magnetic resonance-guided radiation therapy, intensity-modulated proton therapy and volumetric-modulated arc therapy for distal esophageal cancer. Barsky AR; George J; Wroe AJ; Mittauer KE; Kaiser A; Herrera R; Yu J; Gutierrez AN; Alvarez D; McCulloch J; Kasper ME; Mehta MP; Chuong MD Med Dosim; 2024 Summer; 49(2):121-126. PubMed ID: 38001010 [TBL] [Abstract][Full Text] [Related]
20. Multi-scenario based robust intensity-modulated proton therapy (IMPT) plans can account for set-up errors more effectively in terms of normal tissue sparing than planning target volume (PTV) based intensity-modulated photon plans in the head and neck region. Stuschke M; Kaiser A; Abu Jawad J; Pöttgen C; Levegrün S; Farr J Radiat Oncol; 2013 Jun; 8():145. PubMed ID: 23773560 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]