These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

284 related articles for article (PubMed ID: 28684186)

  • 1. Valve-in-Valve Transcatheter Aortic Valve Replacements: To TEE or not to TEE?
    Khoche S; Pollock J; Golts E
    J Cardiothorac Vasc Anesth; 2017 Oct; 31(5):1720-1723. PubMed ID: 28684186
    [No Abstract]   [Full Text] [Related]  

  • 2. Assessment of Paravalvular Leak After Transcatheter Aortic Valve Replacement: Transesophageal Echocardiography Compared With Transthoracic Echocardiography.
    Teeter EG; Dakik C; Cooter M; Samad Z; Ghadimi K; Harrison JK; Gaca J; Stafford-Smith M; Bottiger BA
    J Cardiothorac Vasc Anesth; 2017 Aug; 31(4):1278-1284. PubMed ID: 28800985
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of device landing zone calcification on paravalvular regurgitation after transcatheter aortic valve replacement: a real-time three-dimensional transesophageal echocardiographic study.
    Mihara H; Shibayama K; Berdejo J; Harada K; Itabashi Y; Siegel RJ; Kashif M; Jilaihawi H; Makkar RR; Shiota T
    J Am Soc Echocardiogr; 2015 Apr; 28(4):404-14. PubMed ID: 25560483
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Evolution of Echocardiographic Type and Anesthetic Technique for Transcatheter Aortic Valve Replacement at a High-Volume Transcatheter Aortic Valve Replacement Center.
    Marino M; Lilie CJ; Culp WC; Schepel SR; Tippett JC
    J Cardiothorac Vasc Anesth; 2019 Jan; 33(1):29-35. PubMed ID: 30087025
    [TBL] [Abstract][Full Text] [Related]  

  • 5. TEE-guided transcatheter aortic valve implantation with "zero contrast" - a viable alternative for patients with chronic kidney disease.
    Pershad A; Fraij G; Girotra SV; Fang HK; Gellert G
    J Invasive Cardiol; 2015 Feb; 27(2):E25-6. PubMed ID: 25661767
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Large-field intravascular ultrasound for annular sizing and predicting paravalvular regurgitation during TAVR: comparisons with multidetector computed tomography and transoesophageal echocardiography.
    Hakim D; Ghimire G; Alli OO; Singh S; Sasse MF; Booker OJ; Arora G; Leesar T; Jernigan L; Melby SJ; Davies JE; Leesar MA
    Eur Heart J Cardiovasc Imaging; 2017 Dec; 18(12):1404-1413. PubMed ID: 28165129
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is intra-procedure three-dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?
    Hafiz AM; Medranda GA; Kakouros N; Patel J; Kahan J; Gubernikoff G; Ray B; Paruchuri V; DeLeon J; Marzo K; Calixte R; Gaztanaga J
    Echocardiography; 2017 Aug; 34(8):1195-1202. PubMed ID: 28722306
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Superiority of novel automated assessment of aortic annulus by intraoperative three-dimensional transesophageal echocardiography in patients with severe aortic stenosis: Comparison with conventional cross-sectional assessment.
    Kato N; Shibayama K; Noguchi M; Makihara Y; Okumura H; Obunai K; Isobe M; Hirao K; Watanabe H
    J Cardiol; 2018 Oct; 72(4):321-327. PubMed ID: 29650399
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Echocardiography in transcatheter aortic (Core)Valve implantation: Part 2-Transesophageal echocardiography.
    Naqvi TZ
    Echocardiography; 2018 Jul; 35(7):1020-1041. PubMed ID: 29981214
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Real-time three-dimensional transesophageal echocardiography adds value to transcatheter aortic valve implantation.
    Smith LA; Dworakowski R; Bhan A; Delithanasis I; Hancock J; Maccarthy PA; Wendler O; Thomas MR; Monaghan MJ
    J Am Soc Echocardiogr; 2013 Apr; 26(4):359-69. PubMed ID: 23484436
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Device landing zone calcification predicts significant paravalvular regurgitation after transcatheter aortic valve replacement: a real time three-dimensional transesophageal echocardiography study.
    Mihara H; Shibayama K; Harada K; Berdejo J; Itabashi Y; Makkar RR; Shiota T
    Echocardiography; 2014 May; 31(5):E142-4. PubMed ID: 25224213
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.
    Jilaihawi H; Doctor N; Kashif M; Chakravarty T; Rafique A; Makar M; Furugen A; Nakamura M; Mirocha J; Gheorghiu M; Stegic J; Okuyama K; Sullivan DJ; Siegel R; Min JK; Gurudevan SV; Fontana GP; Cheng W; Friede G; Shiota T; Makkar RR
    J Am Coll Cardiol; 2013 Mar; 61(9):908-16. PubMed ID: 23449425
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of Methodologic Differences in Three-Dimensional Echocardiographic Measurements of the Aortic Annulus Compared with Computed Tomographic Angiography Before Transcatheter Aortic Valve Replacement.
    Khalique OK; Hamid NB; White JM; Bae DJ; Kodali SK; Nazif TM; Vahl TP; Paradis JM; George I; Leon MB; Hahn RT
    J Am Soc Echocardiogr; 2017 Apr; 30(4):414-421. PubMed ID: 27939049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial.
    Willson AB; Webb JG; Freeman M; Wood DA; Gurvitch R; Thompson CR; Moss RR; Toggweiler S; Binder RK; Munt B; Cheung A; Hague C; Ye J; Leipsic JA
    J Cardiovasc Comput Tomogr; 2012; 6(6):406-14. PubMed ID: 23127390
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The transition from transesophageal to transthoracic echocardiography during transcatheter aortic valve replacement: an evolving field.
    Kinno M; Cantey EP; Rigolin VH
    J Echocardiogr; 2019 Mar; 17(1):25-34. PubMed ID: 30465271
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-dimensional Transesophageal Echocardiography Before Transcatheter Aortic Valve Implantation.
    Azevedo AI; Fontes-Carvalho R; Sampaio F
    Rev Esp Cardiol (Engl Ed); 2016 Jul; 69(7):695. PubMed ID: 26924675
    [No Abstract]   [Full Text] [Related]  

  • 17. 3D Transesophageal Echocardiography for Guiding Transcatheter Aortic Valve Replacement Without Prior Cardiac Computed Tomography in Patients With Renal Dysfunction.
    Hana D; Miller T; Skaff P; Seetharam K; Suleiman S; Raybuck B; Kawsara A; Wei L; Roberts H; Cook C; Badhwar V; Daggubati R; Mills J; Sengupta P; Hamirani Y
    Cardiovasc Revasc Med; 2022 Aug; 41():63-68. PubMed ID: 35039228
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction.
    Little SH; Oh JK; Gillam L; Sengupta PP; Orsinelli DA; Cavalcante JL; Chang JD; Adams DH; Zorn GL; Pollak AW; Abdelmoneim SS; Reardon MJ; Qiao H; Popma JJ
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27313280
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Outcomes and Safety of Transcatheter Aortic Valve Implantation With and Without Routine Use of Transesophageal Echocardiography.
    Bhatnagar UB; Gedela M; Sethi P; Desai C; Petraskova T; Heard A; Thompson P; Stys AT; Stys TP
    Am J Cardiol; 2018 Oct; 122(7):1210-1214. PubMed ID: 30292281
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.