These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 28685439)

  • 1. Brain Tissue PO
    Xu K; Boas DA; Sakadžić S; LaManna JC
    Adv Exp Med Biol; 2017; 977():149-153. PubMed ID: 28685439
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of Local Partial Pressure of Oxygen in the Brain Tissue under Normoxia and Epilepsy with Phosphorescence Lifetime Microscopy.
    Zhang C; Bélanger S; Pouliot P; Lesage F
    PLoS One; 2015; 10(8):e0135536. PubMed ID: 26305777
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cerebral blood oxygenation measurement based on oxygen-dependent quenching of phosphorescence.
    Sakadžić S; Roussakis E; Yaseen MA; Mandeville ET; Srinivasan VJ; Arai K; Ruvinskaya S; Wu W; Devor A; Lo EH; Vinogradov SA; Boas DA
    J Vis Exp; 2011 May; (51):. PubMed ID: 21587157
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Oxyphor 2P: A High-Performance Probe for Deep-Tissue Longitudinal Oxygen Imaging.
    Esipova TV; Barrett MJP; Erlebach E; Masunov AE; Weber B; Vinogradov SA
    Cell Metab; 2019 Mar; 29(3):736-744.e7. PubMed ID: 30686745
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of cerebral oxygen pressure in living mice by two-photon phosphorescence lifetime microscopy.
    Erlebach E; Ravotto L; Wyss MT; Condrau J; Troxler T; Vinogradov SA; Weber B
    STAR Protoc; 2022 Jun; 3(2):101370. PubMed ID: 35573482
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Response of inner retinal oxygen extraction fraction to light flicker under normoxia and hypoxia in rat.
    Teng PY; Wanek J; Blair NP; Shahidi M
    Invest Ophthalmol Vis Sci; 2014 Sep; 55(9):6055-8. PubMed ID: 25183761
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of brain tissue O2 supply based on results of PO2 measurements with needle and surface microelectrodes.
    Grote J; Laue O; Eiring P; Wehler M
    J Auton Nerv Syst; 1996 Mar; 57(3):168-72. PubMed ID: 8964943
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantitating intracellular oxygen tension in vivo by phosphorescence lifetime measurement.
    Hirakawa Y; Yoshihara T; Kamiya M; Mimura I; Fujikura D; Masuda T; Kikuchi R; Takahashi I; Urano Y; Tobita S; Nangaku M
    Sci Rep; 2015 Dec; 5():17838. PubMed ID: 26644023
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mapping oxygen concentration in the awake mouse brain.
    Lyons DG; Parpaleix A; Roche M; Charpak S
    Elife; 2016 Feb; 5():. PubMed ID: 26836304
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of microregional hypoxia in mouse cerebral cortex by two-photon imaging of endogenous NADH fluorescence.
    Polesskaya O; Sun A; Salahura G; Silva JN; Dewhurst S; Kasischke K
    J Vis Exp; 2012 Feb; (60):. PubMed ID: 22370971
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Oxygen imaging of hypoxic pockets in the mouse cerebral cortex.
    Beinlich FRM; Asiminas A; Untiet V; Bojarowska Z; Plá V; Sigurdsson B; Timmel V; Gehrig L; Graber MH; Hirase H; Nedergaard M
    Science; 2024 Mar; 383(6690):1471-1478. PubMed ID: 38547288
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous imaging of cortical partial oxygen pressure and anatomic structures using a transparent optical sensor foil.
    Warnat J; Liebsch G; Stoerr EM; Brawanski A; Woertgen C
    J Neurosurg Anesthesiol; 2008 Apr; 20(2):116-23. PubMed ID: 18362773
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Two-Photon Phosphorescence Lifetime Microscopy.
    Abbasizadeh N; Spencer JA
    Adv Exp Med Biol; 2021; 3233():63-82. PubMed ID: 34053023
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Two-photon phosphorescence lifetime microscopy of retinal capillary plexus oxygenation in mice.
    Şencan İ; Esipova TV; Yaseen MA; Fu B; Boas DA; Vinogradov SA; Shahidi M; Sakadžić S
    J Biomed Opt; 2018 Dec; 23(12):1-9. PubMed ID: 30516039
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Direct measurement of local oxygen concentration in the bone marrow of live animals.
    Spencer JA; Ferraro F; Roussakis E; Klein A; Wu J; Runnels JM; Zaher W; Mortensen LJ; Alt C; Turcotte R; Yusuf R; Côté D; Vinogradov SA; Scadden DT; Lin CP
    Nature; 2014 Apr; 508(7495):269-73. PubMed ID: 24590072
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intravital phosphorescence lifetime imaging of the renal cortex accurately measures renal hypoxia.
    Hirakawa Y; Mizukami K; Yoshihara T; Takahashi I; Khulan P; Honda T; Mimura I; Tanaka T; Tobita S; Nangaku M
    Kidney Int; 2018 Jun; 93(6):1483-1489. PubMed ID: 29606399
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements.
    Mik EG; van Leeuwen TG; Raat NJ; Ince C
    J Appl Physiol (1985); 2004 Nov; 97(5):1962-9. PubMed ID: 15247164
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retinal tissue oxygen tension imaging in the rat.
    Shahidi M; Wanek J; Blair NP; Little DM; Wu T
    Invest Ophthalmol Vis Sci; 2010 Sep; 51(9):4766-70. PubMed ID: 20375336
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantification of longitudinal tissue pO2 gradients in window chamber tumours: impact on tumour hypoxia.
    Dewhirst MW; Ong ET; Braun RD; Smith B; Klitzman B; Evans SM; Wilson D
    Br J Cancer; 1999 Apr; 79(11-12):1717-22. PubMed ID: 10206282
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Brain surface pO2 and rCBF in rabbits with a focal cerebral lesion and pulmonary hypoxia under fentanyl-, isoflurane- or thiopental-anesthesia.
    Berger S; Murr R; Schürer L; Enzenbach R; Peter K; Baethmann A
    Adv Exp Med Biol; 1992; 317():723-9. PubMed ID: 1288195
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.