These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

596 related articles for article (PubMed ID: 28698929)

  • 1. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.
    Schotanus MGM; Thijs E; Heijmans M; Vos R; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2659-2668. PubMed ID: 28698929
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: A meta-analysis.
    An VV; Sivakumar BS; Phan K; Levy YD; Bruce WJ
    J Orthop Sci; 2017 Jan; 22(1):116-120. PubMed ID: 27823847
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation.
    Schotanus MGM; Thijs E; Boonen B; Kerens B; Jong B; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1656-1661. PubMed ID: 28785788
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Favourable rotational alignment outcomes in PSI knee arthroplasty: A Level 1 systematic review and meta-analysis.
    Mannan A; Smith TO
    Knee; 2016 Mar; 23(2):186-90. PubMed ID: 26782300
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting.
    Suero EM; Lueke U; Stuebig T; Hawi N; Krettek C; Liodakis E
    Orthop Traumatol Surg Res; 2018 Nov; 104(7):971-975. PubMed ID: 29704634
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CT- versus MRI-based patient-specific instrumentation for total knee arthroplasty: A systematic review and meta-analysis.
    Wu XD; Xiang BY; Schotanus MGM; Liu ZH; Chen Y; Huang W
    Surgeon; 2017 Dec; 15(6):336-348. PubMed ID: 28756064
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fewer femoral rotational outliers produced with CT- than with MRI-based patient-specific instrumentation in total knee arthroplasty.
    Li Z; Yang Z; Liao W; Wang W; Zou Y; Pan Y; Feng Z
    Knee Surg Sports Traumatol Arthrosc; 2020 Sep; 28(9):2930-2941. PubMed ID: 31435705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. No evidence of superiority in reducing outliers of component alignment for patient-specific instrumentation for total knee arthroplasty: a systematic review.
    Zhang QM; Chen JY; Li H; Chai W; Ni M; Zhang ZD; Yang F
    Orthop Surg; 2015 Feb; 7(1):19-25. PubMed ID: 25708031
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation.
    Parratte S; Blanc G; Boussemart T; Ollivier M; Le Corroller T; Argenson JN
    Knee Surg Sports Traumatol Arthrosc; 2013 Oct; 21(10):2213-9. PubMed ID: 23942938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Plain radiograph fails to reflect the alignment and advantages of navigation in total knee arthroplasty.
    Choi WC; Lee S; An JH; Kim D; Seong SC; Lee MC
    J Arthroplasty; 2011 Aug; 26(5):756-64. PubMed ID: 20875940
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Patient-specific instrumentation does not improve alignment in total knee arthroplasty.
    Russell R; Brown T; Huo M; Jones R
    J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty.
    Gong S; Xu W; Wang R; Wang Z; Wang B; Han L; Chen G
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1083-1095. PubMed ID: 30377714
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.
    Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does Patient-Specific Instrumentation Improve Femoral and Tibial Component Alignment in Total Knee Arthroplasty? A Prospective Randomized Study.
    Stolarczyk A; Nagraba L; Mitek T; Stolarczyk M; Deszczyński JM; Jakucinski M
    Adv Exp Med Biol; 2018; 1096():11-17. PubMed ID: 29623574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.
    Yamamura K; Minoda Y; Sugama R; Ohta Y; Nakamura S; Ueyama H; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1560-1567. PubMed ID: 31240377
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial.
    Boonen B; Schotanus MG; Kerens B; van der Weegen W; van Drumpt RA; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2013 Oct; 21(10):2206-12. PubMed ID: 23928929
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation.
    Kerens B; Leenders AM; Schotanus MGM; Boonen B; Tuinebreijer WE; Emans PJ; Jong B; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1823-1830. PubMed ID: 29282486
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.
    Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E
    Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.
    Tandogan RN; Kort NP; Ercin E; van Rooij F; Nover L; Saffarini M; Hirschmann MT; Becker R; Dejour D;
    Knee Surg Sports Traumatol Arthrosc; 2022 Aug; 30(8):2654-2665. PubMed ID: 33646370
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of Patient-Specific Instruments in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.
    Thienpont E; Schwab PE; Fennema P
    J Bone Joint Surg Am; 2017 Mar; 99(6):521-530. PubMed ID: 28291186
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 30.