172 related articles for article (PubMed ID: 28699063)
1. Determination of Collision Cross Sections Using a Fourier Transform Electrostatic Linear Ion Trap Mass Spectrometer.
Dziekonski ET; Johnson JT; Lee KW; McLuckey SA
J Am Soc Mass Spectrom; 2018 Feb; 29(2):242-250. PubMed ID: 28699063
[TBL] [Abstract][Full Text] [Related]
2. Extracting biomolecule collision cross sections from the high-resolution FT-ICR mass spectral linewidths.
Jiang T; Chen Y; Mao L; Marshall AG; Xu W
Phys Chem Chem Phys; 2016 Jan; 18(2):713-7. PubMed ID: 26314765
[TBL] [Abstract][Full Text] [Related]
3. Collision cross section (CCS) measurement by ion cyclotron resonance mass spectrometry with short-time Fourier transform.
Hu M; Zhang L; He S; Xu C; Shi Q
Rapid Commun Mass Spectrom; 2018 May; 32(9):751-761. PubMed ID: 29486526
[TBL] [Abstract][Full Text] [Related]
4. Quantitative Collision Cross-Sections from FTICR Linewidth Measurements: Improvements in Theory and Experiment.
Anupriya ; Gustafson E; Mortensen DN; Dearden DV
J Am Soc Mass Spectrom; 2018 Feb; 29(2):251-259. PubMed ID: 28733966
[TBL] [Abstract][Full Text] [Related]
5. Collision cross section measurements for biomolecules within a high-resolution FT-ICR cell: theory.
Guo D; Xin Y; Li D; Xu W
Phys Chem Chem Phys; 2015 Apr; 17(14):9060-7. PubMed ID: 25754983
[TBL] [Abstract][Full Text] [Related]
6. Determination of Collision Cross-Sections of Protein Ions in an Orbitrap Mass Analyzer.
Sanders JD; Grinfeld D; Aizikov K; Makarov A; Holden DD; Brodbelt JS
Anal Chem; 2018 May; 90(9):5896-5902. PubMed ID: 29608288
[TBL] [Abstract][Full Text] [Related]
7. Complementing the characterization of in vivo generated N-glucuronic acid conjugates of stanozolol by collision cross section computation and analysis.
Thevis M; Dib J; Thomas A; Höppner S; Lagojda A; Kuehne D; Sander M; Opfermann G; Schänzer W
Drug Test Anal; 2015; 7(11-12):1050-6. PubMed ID: 26514814
[TBL] [Abstract][Full Text] [Related]
8. Utility of Higher Harmonics in Electrospray Ionization Fourier Transform Electrostatic Linear Ion Trap Mass Spectrometry.
Dziekonski ET; Johnson JT; McLuckey SA
Anal Chem; 2017 Apr; 89(8):4392-4397. PubMed ID: 28326764
[TBL] [Abstract][Full Text] [Related]
9. Effects of drift gas on collision cross sections of a protein standard in linear drift tube and traveling wave ion mobility mass spectrometry.
Jurneczko E; Kalapothakis J; Campuzano ID; Morris M; Barran PE
Anal Chem; 2012 Oct; 84(20):8524-31. PubMed ID: 22974196
[TBL] [Abstract][Full Text] [Related]
10. Multi-CRAFTI: Relative Collision Cross Sections from Fourier Transform Ion Cyclotron Resonance Mass Spectrometric Line Width Measurements.
Pope BL; Joaquin D; Hickey JT; Mismash N; Heravi T; Shrestha J; Arslanian AJ; Anupriya ; Mortensen DN; Dearden DV
J Am Soc Mass Spectrom; 2022 Jan; 33(1):131-140. PubMed ID: 34928604
[TBL] [Abstract][Full Text] [Related]
11. Conformational ordering of biomolecules in the gas phase: nitrogen collision cross sections measured on a prototype high resolution drift tube ion mobility-mass spectrometer.
May JC; Goodwin CR; Lareau NM; Leaptrot KL; Morris CB; Kurulugama RT; Mordehai A; Klein C; Barry W; Darland E; Overney G; Imatani K; Stafford GC; Fjeldsted JC; McLean JA
Anal Chem; 2014 Feb; 86(4):2107-16. PubMed ID: 24446877
[TBL] [Abstract][Full Text] [Related]
12. Cyclodextrin and malto-dextrose collision cross sections determined in a drift tube ion mobility mass spectrometer using nitrogen bath gas.
Klein C; Cologna SM; Kurulugama RT; Blank PS; Darland E; Mordehai A; Backlund PS; Yergey AL
Analyst; 2018 Aug; 143(17):4147-4154. PubMed ID: 30065998
[TBL] [Abstract][Full Text] [Related]
13. Determining Energies and Cross Sections of Individual Ions Using Higher-Order Harmonics in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS).
Harper CC; Elliott AG; Lin HW; Williams ER
J Am Soc Mass Spectrom; 2018 Sep; 29(9):1861-1869. PubMed ID: 29860679
[TBL] [Abstract][Full Text] [Related]
14. New High Resolution Ion Mobility Mass Spectrometer Capable of Measurements of Collision Cross Sections from 150 to 520 K.
Ujma J; Giles K; Morris M; Barran PE
Anal Chem; 2016 Oct; 88(19):9469-9478. PubMed ID: 27573618
[TBL] [Abstract][Full Text] [Related]
15. First-Principles Collision Cross Section Measurements of Large Proteins and Protein Complexes.
McCabe JW; Mallis CS; Kocurek KI; Poltash ML; Shirzadeh M; Hebert MJ; Fan L; Walker TE; Zheng X; Jiang T; Dong S; Lin CW; Laganowsky A; Russell DH
Anal Chem; 2020 Aug; 92(16):11155-11163. PubMed ID: 32662991
[TBL] [Abstract][Full Text] [Related]
16. Fourier Transform-Ion Mobility Linear Ion Trap Mass Spectrometer Using Frequency Encoding for Recognition of Related Compounds in a Single Acquisition.
Schrader RL; Marsh BM; Cooks RG
Anal Chem; 2020 Apr; 92(7):5107-5115. PubMed ID: 32122122
[TBL] [Abstract][Full Text] [Related]
17. Gas molecule scattering & ion mobility measurements for organic macro-ions in He versus N2 environments.
Larriba-Andaluz C; Fernández-García J; Ewing MA; Hogan CJ; Clemmer DE
Phys Chem Chem Phys; 2015 Jun; 17(22):15019-29. PubMed ID: 25988389
[TBL] [Abstract][Full Text] [Related]
18. Ion mobility spectrometry-mass spectrometry examination of the structures, stabilities, and extents of hydration of dimethylamine-sulfuric acid clusters.
Thomas JM; He S; Larriba-Andaluz C; DePalma JW; Johnston MV; Hogan CJ
Phys Chem Chem Phys; 2016 Aug; 18(33):22962-72. PubMed ID: 27485283
[TBL] [Abstract][Full Text] [Related]
19. Extracting biomolecule collision cross sections from FT-ICR mass spectral line shape.
Tang Y; Li D; Cao D; Xu W
Talanta; 2019 Dec; 205():120093. PubMed ID: 31450431
[TBL] [Abstract][Full Text] [Related]
20. Collision cross sectional areas from analysis of Fourier transform ion cyclotron resonance line width: a new method for characterizing molecular structure.
Yang F; Voelkel JE; Dearden DV
Anal Chem; 2012 Jun; 84(11):4851-7. PubMed ID: 22540423
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]