BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

264 related articles for article (PubMed ID: 28699399)

  • 21. Accuracy of infrared ear thermometry and traditional temperature methods in young children.
    Erickson RS; Woo TM
    Heart Lung; 1994; 23(3):181-95. PubMed ID: 8039988
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of temporal artery to mercury and digital temperature measurement in pediatrics.
    Işler A; Aydin R; Tutar Güven S; Günay S
    Int Emerg Nurs; 2014 Jul; 22(3):165-8. PubMed ID: 24183491
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients.
    Hebbar K; Fortenberry JD; Rogers K; Merritt R; Easley K
    Pediatr Crit Care Med; 2005 Sep; 6(5):557-61. PubMed ID: 16148817
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of different methods of temperature measurements in sick newborns.
    Uslu S; Ozdemir H; Bulbul A; Comert S; Bolat F; Can E; Nuhoglu A
    J Trop Pediatr; 2011 Dec; 57(6):418-23. PubMed ID: 21245075
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Agreement between axillary, tympanic, and mid-forehead body temperature measurements in adult emergency department patients.
    Sener S; Karcioglu O; Eken C; Yaylaci S; Ozsarac M
    Eur J Emerg Med; 2012 Aug; 19(4):252-6. PubMed ID: 21945968
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Comparison of body temperatures in children measured using 3 different thermometers: tympanic, skin and digital axillary].
    Padilla-Raygoza N; Ruiz-Paloalto ML; Díaz-Guerrero R; Olvera-Villanueva G; Maldonado A; Raygoza-Mendoza Mdel P
    Enferm Clin; 2014; 24(3):175-82. PubMed ID: 24735910
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparative study on the accuracy of noninvasive thermometers.
    Fadzil FM; Choon D; Arumugam K
    Aust Fam Physician; 2010 Apr; 39(4):237-9. PubMed ID: 20372685
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Performance of axillary and rectal temperature measurement in private pediatric practice.
    Teller J; Bernasconi R; Simonetti GD; Lava SAG
    Eur J Pediatr; 2019 Oct; 178(10):1501-1505. PubMed ID: 31396691
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The inaccuracy of axillary temperatures measured with an electronic thermometer.
    Ogren JM
    Am J Dis Child; 1990 Jan; 144(1):109-11. PubMed ID: 2294708
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A comparison of temperature-taking methods in neonates.
    Leick-Rude MK; Bloom LF
    Neonatal Netw; 1998 Aug; 17(5):21-37. PubMed ID: 9791443
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children.
    Kongpanichkul A; Bunjongpak S
    J Med Assoc Thai; 2000 Sep; 83(9):1068-76. PubMed ID: 11075975
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical performance of infrared consumer-grade thermometers.
    Hamilton PA; Kasbekar RS; Monro R
    J Nurs Meas; 2013; 21(2):166-77. PubMed ID: 24053050
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Galinstan thermometer is more accurate than digital for the measurement of body temperature in children.
    Schreiber S; Minute M; Tornese G; Giorgi R; Duranti M; Ronfani L; Barbi E
    Pediatr Emerg Care; 2013 Feb; 29(2):197-9. PubMed ID: 23364385
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population.
    Jean-Mary MB; Dicanzio J; Shaw J; Bernstein HH
    J Pediatr; 2002 Nov; 141(5):671-6. PubMed ID: 12410196
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The factors that have a role in variability for temperature.
    Yalçin SS; Aydemir O; Erkul E; Karabulut E; Akça T
    J Trop Pediatr; 2010 Feb; 56(1):53-9. PubMed ID: 19602486
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Precision, Sensitivity and Patient Preference of Non-Invasive Thermometers in a Pediatric Surgical Acute Care Setting.
    Opersteny E; Anderson H; Bates J; Davenport K; Husby J; Myking K; Oron AP
    J Pediatr Nurs; 2017; 35():36-41. PubMed ID: 28728767
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measuring the body temperature: how accurate is the Tempa Dot?
    Van den Bruel A; Aertgeerts B; De Boeck C; Buntinx F
    Technol Health Care; 2005; 13(2):97-106. PubMed ID: 15912007
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.
    Khorshid L; Eşer I; Zaybak A; Yapucu U
    J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757
    [TBL] [Abstract][Full Text] [Related]  

  • 39. How reliable is axillary temperature measurement?
    Falzon A; Grech V; Caruana B; Magro A; Attard-Montalto S
    Acta Paediatr; 2003; 92(3):309-13. PubMed ID: 12725545
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Body Core Temperature Assessment in Emergency Care Departments.
    Daanen HAM; Hoitinga G; Kruijt DJ; Koning KS; Verheijen PP; de Baas SIM; Bergsma AR; Snethlage CE; Al-Bander I; Teunissen LPJ
    J Emerg Med; 2024 Mar; 66(3):e277-e283. PubMed ID: 38336570
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.