123 related articles for article (PubMed ID: 28705926)
1. Incidental Findings on Myocardial Perfusion SPECT Images.
Muzaffar R; Raslan O; Ahmed F; Goldfarb L; Sterkel B; Osman MM
J Nucl Med Technol; 2017 Sep; 45(3):175-180. PubMed ID: 28705926
[TBL] [Abstract][Full Text] [Related]
2. Incidental Liver Findings in 99mTc-Sestamibi Myocardial Perfusion SPECT.
De Lorenzo A; da Cruz Netto PG; Pedras Pde S
J Nucl Med Technol; 2016 Mar; 44(1):42-3. PubMed ID: 26111712
[TBL] [Abstract][Full Text] [Related]
3. Unusual extracardiac findings detected on myocardial perfusion single photon emission computed tomography studies with Tc-99m sestamibi.
Gedik GK; Ergün EL; Aslan M; Caner B
Clin Nucl Med; 2007 Dec; 32(12):920-6. PubMed ID: 18030041
[TBL] [Abstract][Full Text] [Related]
4. Clinical Utility of Enhanced Relative Activity Recovery on Systolic Myocardial Perfusion SPECT: Lessons from PET.
Kitkungvan D; Vejpongsa P; Korrane KP; Sdringola S; Gould KL
J Nucl Med; 2015 Dec; 56(12):1882-8. PubMed ID: 26272807
[TBL] [Abstract][Full Text] [Related]
5. Altered biodistribution and incidental findings on myocardial perfusion imaging.
Chamarthy M; Travin MI
Semin Nucl Med; 2010 Jul; 40(4):257-70. PubMed ID: 20513448
[TBL] [Abstract][Full Text] [Related]
6. Incidental Detection of Locally Progressed Pancreatic Cancer on SPECT Myocardial Perfusion Images.
Erinne I; Kempf J
J Nucl Cardiol; 2020 Jun; 27(3):1068-1070. PubMed ID: 31485961
[No Abstract] [Full Text] [Related]
7. Incidentally found giant thymomas by SPECT myocardial perfusion imaging.
Farag AA; Hage FG
J Nucl Cardiol; 2015 Apr; 22(2):385-7. PubMed ID: 25367454
[No Abstract] [Full Text] [Related]
8. Clinical significance of mild inferolateral wall ischemia of the left ventricle on 99mTc-MIBI myocardial perfusion single photon emission computed tomography (SPECT).
Assadi M; Abdi-Ardekani A; Pourbehi M; Amini A; Javadi H; Nabipour I; Abbaszadeh M; Assadi M
Eur Rev Med Pharmacol Sci; 2013 Oct; 17(19):2639-43. PubMed ID: 24142612
[TBL] [Abstract][Full Text] [Related]
9. Incidental Primary Breast Lymphoma on 99mTc-Sestamibi Myocardial Perfusion Imaging With SPECT/CT.
Deng Z; Dong A; Zhao M; Tang Y; Liu Y
Clin Nucl Med; 2019 Aug; 44(8):e492-e494. PubMed ID: 31274632
[TBL] [Abstract][Full Text] [Related]
10. What is this image? 2021: Image 6 result : The curious case of the hidden liver: Polycystic liver disease as depicted on planar projection images of a Tc-99m Sestamibi SPECT MPI study.
Rauba J; Harland D; Ajam T; Port S
J Nucl Cardiol; 2021 Jun; 28(3):807-811. PubMed ID: 34009636
[No Abstract] [Full Text] [Related]
11. Prevalence of noncardiac findings on low dose 64-slice computed tomography used for attenuation correction in myocardial perfusion imaging with SPECT.
Husmann L; Tatsugami F; Aepli U; Herzog BA; Valenta I; Veit-Haibach P; Buechel RR; Pazhenkottil AP; Gaemperli O; Burkhard N; Wyss CA; Kaufmann PA
Int J Cardiovasc Imaging; 2009 Dec; 25(8):859-65. PubMed ID: 19662511
[TBL] [Abstract][Full Text] [Related]
12. Prognostic Implications of Discordant Results of Myocardial Perfusion Single-Photon Emission Computed Tomography and Exercise ECG Test in Patients with Stable Angina.
Kowalczyk E; Filipiak-Strzecka D; Hamala P; Śmiech N; Kasprzak JD; Kuśmierek J; Płachcińska A; Lipiec P
Adv Clin Exp Med; 2015; 24(6):965-71. PubMed ID: 26771967
[TBL] [Abstract][Full Text] [Related]
13. The value of attenuation correction by hybrid SPECT/CT imaging on infarct size quantification in male patients with previous inferior myocardial infarct.
Giubbini RM; Gabanelli S; Lucchini S; Merli G; Puta E; Rodella C; Motta F; Paghera B; Rossini P; Terzi A; Bertagna F
Nucl Med Commun; 2011 Nov; 32(11):1026-32. PubMed ID: 21897308
[TBL] [Abstract][Full Text] [Related]
14. A randomized, multicenter, multivendor study of myocardial perfusion imaging with regadenoson CT perfusion vs single photon emission CT.
Cury RC; Kitt TM; Feaheny K; Blankstein R; Ghoshhajra BB; Budoff MJ; Leipsic J; Min JK; Akin J; George RT
J Cardiovasc Comput Tomogr; 2015; 9(2):103-12.e1-2. PubMed ID: 25726411
[TBL] [Abstract][Full Text] [Related]
15. Impact of SPECT myocardial perfusion imaging on cardiac care.
Lugomirski P; Chow BJ; Ruddy TD
Expert Rev Cardiovasc Ther; 2014 Nov; 12(11):1247-9. PubMed ID: 25264155
[TBL] [Abstract][Full Text] [Related]
16. Computed tomography myocardial perfusion imaging with 320-row detector computed tomography accurately detects myocardial ischemia in patients with obstructive coronary artery disease.
George RT; Arbab-Zadeh A; Miller JM; Vavere AL; Bengel FM; Lardo AC; Lima JA
Circ Cardiovasc Imaging; 2012 May; 5(3):333-40. PubMed ID: 22447807
[TBL] [Abstract][Full Text] [Related]
17. Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging.
Doukky R; Hayes K; Frogge N; Balakrishnan G; Dontaraju VS; Rangel MO; Golzar Y; Garcia-Sayan E; Hendel RC
Circulation; 2013 Oct; 128(15):1634-43. PubMed ID: 24021779
[TBL] [Abstract][Full Text] [Related]
18. Coronary calcium score as an adjunct to nuclear myocardial perfusion imaging for risk stratification before noncardiac surgery.
Ghadri JR; Fiechter M; Veraguth K; Gebhard C; Pazhenkottil AP; Fuchs TA; Templin C; Gaemperli O; Kaufmann PA
J Nucl Med; 2012 Jul; 53(7):1081-6. PubMed ID: 22611255
[TBL] [Abstract][Full Text] [Related]
19. Clinical usefulness of a collimator distance dependent resolution recovery in myocardial perfusion SPECT: a clinical report from a single institute.
Tashiro K; Tomiguchi S; Shiraishi S; Yoshida M; Sakaguchi F; Yamashita Y
Ann Nucl Med; 2011 Feb; 25(2):133-7. PubMed ID: 21104346
[TBL] [Abstract][Full Text] [Related]
20. [Evaluation of hemodynamic significance of arteriovenous coronary fistulas: diagnostic integration of coronary angiography and stress/rest myocardial scintigraphy].
Rubini G; Ettorre GC; Sebastiani M; Bovenzi F
Radiol Med; 2000 Dec; 100(6):453-8. PubMed ID: 11307506
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]