These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 28707132)

  • 21. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating.
    Ozer K; Toker S
    Hand (N Y); 2011 Jun; 6(2):190-3. PubMed ID: 22654703
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture.
    Diong TW; Haflah NHM; Kassim AYM; Habshi SMIA; Shukur MH
    J Hand Surg Asian Pac Vol; 2018 Mar; 23(1):26-32. PubMed ID: 29409409
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Is ultrasound superior to fluoroscopy in distal radius volar fixation?
    Toro-Aguilera Á; Arenas-Romera J; Carrera I; Lamas C
    Hand Surg Rehabil; 2023 Dec; 42(6):488-491. PubMed ID: 37499797
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intraoperative evaluation of dorsal screw prominence after polyaxial volar plate fixation of distal radius fractures utilizing the Hoya view: a cadaveric study.
    Dolce D; Goodwin D; Ludwig M; Edwards S
    Hand (N Y); 2014 Dec; 9(4):511-5. PubMed ID: 25414614
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A Prospective Cohort Study on Accuracy of Dorsal Tangential Views to Avoid Screw Penetration With Volar Plating of Distal Radius Fractures.
    Bergsma M; Bulstra AE; Morris D; Janssen M; Jaarsma R; Doornberg J
    J Orthop Trauma; 2020 Sep; 34(9):e291-e297. PubMed ID: 32815839
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view.
    Haug LC; Glodny B; Deml C; Lutz M; Attal R
    Bone Joint J; 2013 Aug; 95-B(8):1101-5. PubMed ID: 23908427
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures.
    Rausch S; Marintschev I; Graul I; Wilharm A; Klos K; Hofmann GO; Florian Gras M
    Arch Trauma Res; 2015 Jun; 4(2):e24622. PubMed ID: 26101762
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study.
    Williams D; Singh J; Heidari N; Ahmad M; Noorani A; Di Mascio L
    Ann R Coll Surg Engl; 2016 Feb; 98(2):138-42. PubMed ID: 26829667
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Clinical application of special fluoroscopy method in the treatment of distal radius fractures with volar locking plate].
    Zhang R; Niu HM; Guo T; Xie PF; Wu JM; Xie JB; Wang L
    Zhongguo Gu Shang; 2023 Feb; 36(2):128-32. PubMed ID: 36825412
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study.
    Soong M; Got C; Katarincic J; Akelman E
    J Hand Surg Am; 2008 Dec; 33(10):1720-3. PubMed ID: 19084169
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Use of the radial groove view intra-operatively to prevent damage to the extensor pollicis longus tendon by protruding screws during volar plating of a distal radial fracture.
    Lee SK; Bae KW; Choy WS
    Bone Joint J; 2013 Oct; 95-B(10):1372-6. PubMed ID: 24078534
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Systematic use of short unicortical epiphyseal locking screws versus full-length unicortical locking screws in distal radius fracture volar plating: A prospective and comparative study.
    Artuso M; Protais M; Herisson O; Miquel A; Cambon-Binder A; Sautet A
    Eur J Orthop Surg Traumatol; 2022 Jan; 32(1):11-18. PubMed ID: 33661374
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Effect of Radial Shaft Dorsal Screw Prominence in Volar Locking Plate Fixation of Distal Radius Fractures.
    Pulos N; DeGeorge BR; Shin AY; Rizzo M
    Hand (N Y); 2020 Mar; 15(2):271-275. PubMed ID: 30081647
    [No Abstract]   [Full Text] [Related]  

  • 34. Screw prominences related to palmar locking plating of distal radius.
    Sügün TS; Karabay N; Gürbüz Y; Ozaksar K; Toros T; Kayalar M
    J Hand Surg Eur Vol; 2011 May; 36(4):320-4. PubMed ID: 21282227
    [TBL] [Abstract][Full Text] [Related]  

  • 35. What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian M; Simkovic P; Zamborsky R; Skoda A; Labas P
    Bratisl Lek Listy; 2019; 120(7):505-509. PubMed ID: 31602985
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparative study between fixed-angle and polyaxial screws in distal radius fixation with two volar locking plates.
    Toro-Aguilera Á; Martínez-Galarza P; Camacho-Carrasco P; Caballero M; Segur JM
    Orthop Traumatol Surg Res; 2021 Sep; 107(5):102801. PubMed ID: 33383184
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study.
    Thomas AD; Greenberg JA
    J Hand Surg Am; 2009 Feb; 34(2):258-61. PubMed ID: 19121561
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures.
    Brunner A; Siebert C; Stieger C; Kastius A; Link BC; Babst R
    J Hand Surg Am; 2015 Jan; 40(1):27-33. PubMed ID: 25457447
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The dorsal horizon view: detecting screw protrusion at the distal radius.
    Joseph SJ; Harvey JN
    J Hand Surg Am; 2011 Oct; 36(10):1691-3. PubMed ID: 21864994
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation.
    Oc Y; Kilinc BE; Gulcu A; Varol A; Ertugrul R; Kara A
    J Orthop Surg Res; 2018 Apr; 13(1):70. PubMed ID: 29615100
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.