These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

260 related articles for article (PubMed ID: 28712695)

  • 1. Endoleaks after endovascular aortic aneurysm repair: Improved detection with noise-optimized virtual monoenergetic dual-energy CT.
    Martin SS; Wichmann JL; Weyer H; Scholtz JE; Leithner D; Spandorfer A; Bodelle B; Jacobi V; Vogl TJ; Albrecht MH
    Eur J Radiol; 2017 Sep; 94():125-132. PubMed ID: 28712695
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noise-optimized advanced image-based virtual monoenergetic imaging for improved visualization of lung cancer: Comparison with traditional virtual monoenergetic imaging.
    Frellesen C; Kaup M; Wichmann JL; Hüsers K; Scholtz JE; Albrecht MH; Metzger SC; Bauer RW; Kerl JM; Lehnert T; Vogl TJ; Bodelle B
    Eur J Radiol; 2016 Mar; 85(3):665-72. PubMed ID: 26860682
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement.
    Martin SS; Albrecht MH; Wichmann JL; Hüsers K; Scholtz JE; Booz C; Bodelle B; Bauer RW; Metzger SC; Vogl TJ; Lehnert T
    Eur Radiol; 2017 Feb; 27(2):705-714. PubMed ID: 27236818
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen.
    Albrecht MH; Trommer J; Wichmann JL; Scholtz JE; Martin SS; Lehnert T; Vogl TJ; Bodelle B
    Invest Radiol; 2016 Sep; 51(9):582-90. PubMed ID: 26953565
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging.
    Lenga L; Czwikla R; Wichmann JL; Leithner D; Albrecht MH; Booz C; Arendt CT; Yel I; D'Angelo T; Vogl TJ; Martin SS
    Eur J Radiol; 2018 Sep; 106():184-191. PubMed ID: 30150043
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis.
    Leithner D; Mahmoudi S; Wichmann JL; Martin SS; Lenga L; Albrecht MH; Booz C; Arendt CT; Beeres M; D'Angelo T; Bodelle B; Vogl TJ; Scholtz JE
    Eur J Radiol; 2018 Feb; 99():111-117. PubMed ID: 29362140
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions.
    De Cecco CN; Caruso D; Schoepf UJ; De Santis D; Muscogiuri G; Albrecht MH; Meinel FG; Wichmann JL; Burchett PF; Varga-Szemes A; Sheafor DH; Hardie AD
    Eur Radiol; 2018 Aug; 28(8):3393-3404. PubMed ID: 29460075
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Enhanced visualization in endoleak detection through iterative and AI-noise optimized spectral reconstructions.
    Kazimierczak W; Kazimierczak N; Wilamowska J; Wojtowicz O; Nowak E; Serafin Z
    Sci Rep; 2024 Feb; 14(1):3845. PubMed ID: 38360941
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors.
    Martin SS; Pfeifer S; Wichmann JL; Albrecht MH; Leithner D; Lenga L; Scholtz JE; Vogl TJ; Bodelle B
    Abdom Radiol (NY); 2017 Mar; 42(3):718-726. PubMed ID: 27999889
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma.
    Martin SS; Wichmann JL; Pfeifer S; Leithner D; Lenga L; Reynolds MA; D'Angelo T; Hammerstingl R; Gruber-Rouh T; Vogl TJ; Albrecht MH
    Eur J Radiol; 2017 Dec; 97():1-7. PubMed ID: 29153358
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen.
    Martin SS; Wichmann JL; Scholtz JE; Leithner D; D'Angelo T; Weyer H; Booz C; Lenga L; Vogl TJ; Albrecht MH
    J Vasc Interv Radiol; 2017 Sep; 28(9):1257-1266. PubMed ID: 28734847
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Effect of a noise-optimized virtual monoenergetic reconstruction technique on dual-energy CT for image quality of inflammatory bowel disease].
    Yang H; Wu X; Jiang B; Deng K; Sun J; Mei X
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2018 Aug; 43(8):875-881. PubMed ID: 30197316
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dual-Energy Computed Tomography Angiography of the Lower Extremity Runoff: Impact of Noise-Optimized Virtual Monochromatic Imaging on Image Quality and Diagnostic Accuracy.
    Wichmann JL; Gillott MR; De Cecco CN; Mangold S; Varga-Szemes A; Yamada R; Otani K; Canstein C; Fuller SR; Vogl TJ; Todoran TM; Schoepf UJ
    Invest Radiol; 2016 Feb; 51(2):139-46. PubMed ID: 26561048
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dual-energy computed tomography in patients with cutaneous malignant melanoma: Comparison of noise-optimized and traditional virtual monoenergetic imaging.
    Martin SS; Wichmann JL; Weyer H; Albrecht MH; D'Angelo T; Leithner D; Lenga L; Booz C; Scholtz JE; Bodelle B; Vogl TJ; Hammerstingl R
    Eur J Radiol; 2017 Oct; 95():1-8. PubMed ID: 28987652
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography.
    Arendt CT; Czwikla R; Lenga L; Wichmann JL; Albrecht MH; Booz C; Martin SS; Leithner D; Tischendorf P; Blandino A; Vogl TJ; D'Angelo T
    Eur J Radiol; 2020 Jan; 122():108666. PubMed ID: 31786506
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-Energy Low-Kiloelectron Volt versus Single-Energy Low-Kilovolt Images for Endoleak Detection at CT Angiography of the Aorta.
    Landsmann A; Sartoretti T; Mergen V; Jungblut L; Eberhard M; Kobe A; Alkadhi H; Euler A
    Radiol Cardiothorac Imaging; 2024 Apr; 6(2):e230217. PubMed ID: 38451189
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dual-energy CT in patients with abdominal malignant lymphoma: impact of noise-optimised virtual monoenergetic imaging on objective and subjective image quality.
    Lenga L; Czwikla R; Wichmann JL; Leithner D; Albrecht MH; D'Angelo T; Arendt CT; Booz C; Hammerstingl R; Vogl TJ; Martin SS
    Clin Radiol; 2018 Sep; 73(9):833.e19-833.e27. PubMed ID: 29884524
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimal Kiloelectron Volt for Noise-Optimized Virtual Monoenergetic Images of Dual-Energy Pediatric Abdominopelvic Computed Tomography: Preliminary Results.
    Kim TM; Choi YH; Cheon JE; Kim WS; Kim IO; Park JE; Shin SM; Pak SY; Krauss B
    Korean J Radiol; 2019 Feb; 20(2):283-294. PubMed ID: 30672168
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dual-Energy Low-keV or Single-Energy Low-kV CT for Endoleak Detection?: A 6-Reader Study in an Aortic Aneurysm Phantom.
    Skawran S; Angst F; Blüthgen C; Eberhard M; Kälin P; Kobe A; Nagy D; Szucs-Farkas Z; Alkadhi H; Euler A
    Invest Radiol; 2020 Jan; 55(1):45-52. PubMed ID: 31503078
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of the hepatic veins in poor contrast conditions using dual energy CT: evaluation of a novel monoenergetic extrapolation software algorithm.
    Schabel C; Bongers M; Sedlmair M; Korn A; Grosse U; Mangold S; Claussen CD; Thomas C
    Rofo; 2014 Jun; 186(6):591-7. PubMed ID: 24756426
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.