BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

319 related articles for article (PubMed ID: 28716717)

  • 1. Big GABA: Edited MR spectroscopy at 24 research sites.
    Mikkelsen M; Barker PB; Bhattacharyya PK; Brix MK; Buur PF; Cecil KM; Chan KL; Chen DY; Craven AR; Cuypers K; Dacko M; Duncan NW; Dydak U; Edmondson DA; Ende G; Ersland L; Gao F; Greenhouse I; Harris AD; He N; Heba S; Hoggard N; Hsu TW; Jansen JFA; Kangarlu A; Lange T; Lebel RM; Li Y; Lin CE; Liou JK; Lirng JF; Liu F; Ma R; Maes C; Moreno-Ortega M; Murray SO; Noah S; Noeske R; Noseworthy MD; Oeltzschner G; Prisciandaro JJ; Puts NAJ; Roberts TPL; Sack M; Sailasuta N; Saleh MG; Schallmo MP; Simard N; Swinnen SP; Tegenthoff M; Truong P; Wang G; Wilkinson ID; Wittsack HJ; Xu H; Yan F; Zhang C; Zipunnikov V; Zöllner HJ; Edden RAE
    Neuroimage; 2017 Oct; 159():32-45. PubMed ID: 28716717
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Big GABA II: Water-referenced edited MR spectroscopy at 25 research sites.
    Mikkelsen M; Rimbault DL; Barker PB; Bhattacharyya PK; Brix MK; Buur PF; Cecil KM; Chan KL; Chen DY; Craven AR; Cuypers K; Dacko M; Duncan NW; Dydak U; Edmondson DA; Ende G; Ersland L; Forbes MA; Gao F; Greenhouse I; Harris AD; He N; Heba S; Hoggard N; Hsu TW; Jansen JFA; Kangarlu A; Lange T; Lebel RM; Li Y; Lin CE; Liou JK; Lirng JF; Liu F; Long JR; Ma R; Maes C; Moreno-Ortega M; Murray SO; Noah S; Noeske R; Noseworthy MD; Oeltzschner G; Porges EC; Prisciandaro JJ; Puts NAJ; Roberts TPL; Sack M; Sailasuta N; Saleh MG; Schallmo MP; Simard N; Stoffers D; Swinnen SP; Tegenthoff M; Truong P; Wang G; Wilkinson ID; Wittsack HJ; Woods AJ; Xu H; Yan F; Zhang C; Zipunnikov V; Zöllner HJ; Edden RAE
    Neuroimage; 2019 May; 191():537-548. PubMed ID: 30840905
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multi-vendor standardized sequence for edited magnetic resonance spectroscopy.
    Saleh MG; Rimbault D; Mikkelsen M; Oeltzschner G; Wang AM; Jiang D; Alhamud A; Near J; Schär M; Noeske R; Murdoch JB; Ersland L; Craven AR; Dwyer GE; Grüner ER; Pan L; Ahn S; Edden RAE
    Neuroimage; 2019 Apr; 189():425-431. PubMed ID: 30682536
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of acquisition and modeling parameters on the test-retest reproducibility of edited GABA.
    Hupfeld KE; Zöllner HJ; Hui SCN; Song Y; Murali-Manohar S; Yedavalli V; Oeltzschner G; Prisciandaro JJ; Edden RAE
    NMR Biomed; 2024 Apr; 37(4):e5076. PubMed ID: 38091628
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prospective frequency and motion correction for edited
    Marsman A; Lind A; Petersen ET; Andersen M; Boer VO
    Neuroimage; 2021 Jun; 233():117922. PubMed ID: 33662573
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Harmonization of multi-site MRS data with ComBat.
    Bell TK; Godfrey KJ; Ware AL; Yeates KO; Harris AD
    Neuroimage; 2022 Aug; 257():119330. PubMed ID: 35618196
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hadamard editing of glutathione and macromolecule-suppressed GABA.
    Oeltzschner G; Chan KL; Saleh MG; Mikkelsen M; Puts NA; Edden RAE
    NMR Biomed; 2018 Jan; 31(1):. PubMed ID: 29073732
    [TBL] [Abstract][Full Text] [Related]  

  • 8. J-difference-edited MRS measures of γ-aminobutyric acid before and after acute caffeine administration.
    Oeltzschner G; Zöllner HJ; Jonuscheit M; Lanzman RS; Schnitzler A; Wittsack HJ
    Magn Reson Med; 2018 Dec; 80(6):2356-2365. PubMed ID: 29752742
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of seven modelling algorithms for γ-aminobutyric acid-edited proton magnetic resonance spectroscopy.
    Craven AR; Bhattacharyya PK; Clarke WT; Dydak U; Edden RAE; Ersland L; Mandal PK; Mikkelsen M; Murdoch JB; Near J; Rideaux R; Shukla D; Wang M; Wilson M; Zöllner HJ; Hugdahl K; Oeltzschner G
    NMR Biomed; 2022 Jul; 35(7):e4702. PubMed ID: 35078266
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An evaluation of the reproducibility of
    Prisciandaro JJ; Mikkelsen M; Saleh MG; Edden RAE
    Magn Reson Imaging; 2020 Jan; 65():109-113. PubMed ID: 31707293
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reproducibility and effect of tissue composition on cerebellar γ-aminobutyric acid (GABA) MRS in an elderly population.
    Long Z; Dyke JP; Ma R; Huang CC; Louis ED; Dydak U
    NMR Biomed; 2015 Oct; 28(10):1315-23. PubMed ID: 26314380
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of frequency drift on gamma-aminobutyric acid-edited MR spectroscopy.
    Harris AD; Glaubitz B; Near J; John Evans C; Puts NA; Schmidt-Wilcke T; Tegenthoff M; Barker PB; Edden RA
    Magn Reson Med; 2014 Oct; 72(4):941-8. PubMed ID: 24407931
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous edited MRS of GABA and glutathione.
    Saleh MG; Oeltzschner G; Chan KL; Puts NAJ; Mikkelsen M; Schär M; Harris AD; Edden RAE
    Neuroimage; 2016 Nov; 142():576-582. PubMed ID: 27534734
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gannet: A batch-processing tool for the quantitative analysis of gamma-aminobutyric acid–edited MR spectroscopy spectra.
    Edden RA; Puts NA; Harris AD; Barker PB; Evans CJ
    J Magn Reson Imaging; 2014 Dec; 40(6):1445-52. PubMed ID: 25548816
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Normalizing data from GABA-edited MEGA-PRESS implementations at 3 Tesla.
    Harris AD; Puts NAJ; Wijtenburg SA; Rowland LM; Mikkelsen M; Barker PB; Evans CJ; Edden RAE
    Magn Reson Imaging; 2017 Oct; 42():8-15. PubMed ID: 28479342
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spatial variability and reproducibility of GABA-edited MEGA-LASER 3D-MRSI in the brain at 3 T.
    Hnilicová P; Považan M; Strasser B; Andronesi OC; Gajdošík M; Dydak U; Ukropec J; Dobrota D; Trattnig S; Bogner W
    NMR Biomed; 2016 Nov; 29(11):1656-1665. PubMed ID: 27717093
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Frequency drift in MR spectroscopy at 3T.
    Hui SCN; Mikkelsen M; Zöllner HJ; Ahluwalia V; Alcauter S; Baltusis L; Barany DA; Barlow LR; Becker R; Berman JI; Berrington A; Bhattacharyya PK; Blicher JU; Bogner W; Brown MS; Calhoun VD; Castillo R; Cecil KM; Choi YB; Chu WCW; Clarke WT; Craven AR; Cuypers K; Dacko M; de la Fuente-Sandoval C; Desmond P; Domagalik A; Dumont J; Duncan NW; Dydak U; Dyke K; Edmondson DA; Ende G; Ersland L; Evans CJ; Fermin ASR; Ferretti A; Fillmer A; Gong T; Greenhouse I; Grist JT; Gu M; Harris AD; Hat K; Heba S; Heckova E; Hegarty JP; Heise KF; Honda S; Jacobson A; Jansen JFA; Jenkins CW; Johnston SJ; Juchem C; Kangarlu A; Kerr AB; Landheer K; Lange T; Lee P; Levendovszky SR; Limperopoulos C; Liu F; Lloyd W; Lythgoe DJ; Machizawa MG; MacMillan EL; Maddock RJ; Manzhurtsev AV; Martinez-Gudino ML; Miller JJ; Mirzakhanian H; Moreno-Ortega M; Mullins PG; Nakajima S; Near J; Noeske R; Nordhøy W; Oeltzschner G; Osorio-Duran R; Otaduy MCG; Pasaye EH; Peeters R; Peltier SJ; Pilatus U; Polomac N; Porges EC; Pradhan S; Prisciandaro JJ; Puts NA; Rae CD; Reyes-Madrigal F; Roberts TPL; Robertson CE; Rosenberg JT; Rotaru DG; O'Gorman Tuura RL; Saleh MG; Sandberg K; Sangill R; Schembri K; Schrantee A; Semenova NA; Singel D; Sitnikov R; Smith J; Song Y; Stark C; Stoffers D; Swinnen SP; Tain R; Tanase C; Tapper S; Tegenthoff M; Thiel T; Thioux M; Truong P; van Dijk P; Vella N; Vidyasagar R; Vovk A; Wang G; Westlye LT; Wilbur TK; Willoughby WR; Wilson M; Wittsack HJ; Woods AJ; Wu YC; Xu J; Lopez MY; Yeung DKW; Zhao Q; Zhou X; Zupan G; Edden RAE
    Neuroimage; 2021 Nov; 241():118430. PubMed ID: 34314848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigating GABA concentrations measured with macromolecule suppressed and unsuppressed MEGA-PRESS MR spectroscopy and their relationship with BOLD responses in the occipital cortex.
    Duncan NW; Zhang J; Northoff G; Weng X
    J Magn Reson Imaging; 2019 Oct; 50(4):1285-1294. PubMed ID: 30873721
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA.
    Mullins PG; McGonigle DJ; O'Gorman RL; Puts NA; Vidyasagar R; Evans CJ; ; Edden RA
    Neuroimage; 2014 Feb; 86():43-52. PubMed ID: 23246994
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 3D GABA imaging with real-time motion correction, shim update and reacquisition of adiabatic spiral MRSI.
    Bogner W; Gagoski B; Hess AT; Bhat H; Tisdall MD; van der Kouwe AJW; Strasser B; Marjańska M; Trattnig S; Grant E; Rosen B; Andronesi OC
    Neuroimage; 2014 Dec; 103():290-302. PubMed ID: 25255945
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.