217 related articles for article (PubMed ID: 2871713)
1. [Biomechanical studies of the role of the interfragmentary traction screw in plate osteosynthesis exemplified by a short oblique tibial shaft fracture].
Hopf T; Harnroongroi T
Aktuelle Traumatol; 1986 Apr; 16(2):60-6. PubMed ID: 2871713
[TBL] [Abstract][Full Text] [Related]
2. [Biomechanic study on length of plate in treatment of tibial shaft fracture].
Hu X; Yang S; Xiao D; Lin B; Wang H; Xu Z; Zhao W; Zhang M
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Nov; 22(11):1323-6. PubMed ID: 19068599
[TBL] [Abstract][Full Text] [Related]
3. [Stress relief of the osteosynthesis plate by an interfragmentary plate traction screw].
Klaue K; Frigg R; Perren SM
Helv Chir Acta; 1985 Apr; 52(1):19-23. PubMed ID: 4030364
[No Abstract] [Full Text] [Related]
4. [Interfragmental compression of the Zespol osteosynthesis system. Experimental biomechanical studies].
Hopf T; Osthege S
Z Orthop Ihre Grenzgeb; 1987; 125(5):546-52. PubMed ID: 3433909
[TBL] [Abstract][Full Text] [Related]
5. [Experimental studies of the optimal plate pre-bending angle in compression osteosynthesis with reference to the plastic-elastic behavior of the osteosynthesis plate].
Krapf WP; Hopf T
Z Orthop Ihre Grenzgeb; 1986; 124(5):592-8. PubMed ID: 3811484
[TBL] [Abstract][Full Text] [Related]
6. A triangular support screw improves stability for lateral locking plates in proximal tibial fractures with metaphyseal comminution: a biomechanical analysis.
Baumann P; Ebneter L; Giesinger K; Kuster MS
Arch Orthop Trauma Surg; 2011 Jun; 131(6):815-21. PubMed ID: 21210133
[TBL] [Abstract][Full Text] [Related]
7. The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy.
Plecko M; Lagerpusch N; Pegel B; Andermatt D; Frigg R; Koch R; Sidler M; Kronen P; Klein K; Nuss K; Gedet P; Bürki A; Ferguson SJ; Stoeckle U; Auer JA; von Rechenberg B
Injury; 2012 Jul; 43(7):1041-51. PubMed ID: 22284334
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
Cullen AB; Curtiss S; Lee MA
J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
[TBL] [Abstract][Full Text] [Related]
10. Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model.
Weninger P; Schueller M; Drobetz H; Jamek M; Redl H; Tschegg E
J Trauma; 2009 Oct; 67(4):746-51. PubMed ID: 19820581
[TBL] [Abstract][Full Text] [Related]
11. Rigidity of pure lag-screw fixation as a function of screw inclination in an in vitro spiral osteotomy.
Johner R; Joerger K; Cordey J; Perren SM
Clin Orthop Relat Res; 1983 Sep; (178):74-9. PubMed ID: 6883871
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability.
Stoffel K; Lorenz KU; Kuster MS
J Orthop Trauma; 2007 Jul; 21(6):362-8. PubMed ID: 17620993
[TBL] [Abstract][Full Text] [Related]
13. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study.
Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U
Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909
[TBL] [Abstract][Full Text] [Related]
14. Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep.
Richter H; Plecko M; Andermatt D; Frigg R; Kronen PW; Klein K; Nuss K; Ferguson SJ; Stöckle U; von Rechenberg B
J Bone Joint Surg Am; 2015 Feb; 97(3):208-15. PubMed ID: 25653321
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model.
Dougherty PJ; Kim DG; Meisterling S; Wybo C; Yeni Y
J Orthop Trauma; 2008 Jul; 22(6):399-403. PubMed ID: 18594304
[TBL] [Abstract][Full Text] [Related]
16. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients.
Hasenboehler E; Rikli D; Babst R
Injury; 2007 Mar; 38(3):365-70. PubMed ID: 17241634
[TBL] [Abstract][Full Text] [Related]
17. [The significance of postoperative stability for osseous repair of a multiple fragment fracture. Animal experiment studies].
Heitemeyer U; Claes L; Hierholzer G
Unfallchirurg; 1990 Feb; 93(2):49-55. PubMed ID: 2315714
[TBL] [Abstract][Full Text] [Related]
18. Experimental spiral fractures. An in vitro biomechanical comparison of lag-screw fixation to plate fixation.
Cox LG; Dahners LE; Gilbert JA
Clin Orthop Relat Res; 1989 Jun; (243):189-94. PubMed ID: 2721062
[TBL] [Abstract][Full Text] [Related]
19. [A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures].
Huang P; Tang PF; Yao Q; Liang YT; Tao S; Zhang Q; Guo YZ; Liang XD; Wang Y
Zhongguo Gu Shang; 2008 Apr; 21(4):261-3. PubMed ID: 19102183
[TBL] [Abstract][Full Text] [Related]
20. [Role of the fibula in distal tibial fracture].
Heim U
Z Unfallchir Versicherungsmed; 1990; 83(4):187-95. PubMed ID: 2099165
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]