217 related articles for article (PubMed ID: 2871713)
21. [Biomechanics of plate osteosynthesis. Oblique lag screw - pretension of plates (author's transl)].
Gotzen L; Haas N; Strohfeld G
Unfallheilkunde; 1981 Nov; 84(11):439-43. PubMed ID: 7314299
[No Abstract] [Full Text] [Related]
22. [Biomechanical comparative study of three types of osteosynthesis in the treatment of supra and intercondylar fractures of the humerus in adults].
Fornasiéri C; Staub C; Tourné Y; Rumelhart C; Saragaglia D
Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(3):237-42. PubMed ID: 9255359
[TBL] [Abstract][Full Text] [Related]
23. Fixation of HA-coated unicortical locking screws in a sheep gap model: a comparative biomechanical study.
Moroni A; Pegreffi F; Hoang-Kim A; Tesei F; Giannini S; Wippermann B
J Orthop Trauma; 2008 Jan; 22(1):37-42. PubMed ID: 18176163
[TBL] [Abstract][Full Text] [Related]
24. Optimal orientation of transfixation screws across oblique fractures lines.
Schlicke LH; Panjabi MM; White AA
Clin Orthop Relat Res; 1979 Sep; (143):271-7. PubMed ID: 509833
[TBL] [Abstract][Full Text] [Related]
25. [Mechanical conditions in osteosynthesis performed with 3 spongiosa traction screws according to the A-O method after fracture of neck of femur. A comparative study in osteosynthesis using a 130 degrees angular plate and a traction screw (author's transl)].
Zilch H; Naseband K
Aktuelle Traumatol; 1980 Apr; 10(2):85-103. PubMed ID: 6107017
[No Abstract] [Full Text] [Related]
26. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
[TBL] [Abstract][Full Text] [Related]
27. A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing.
Miller DL; Goswami T
Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1049-62. PubMed ID: 17904257
[TBL] [Abstract][Full Text] [Related]
28. Comparison analysis of the operative treatment results of the femoral neck fractures using side-plate and compression screw and cannulated AO screws.
Stiasny J; Dragan S; Kulej M; Martynkiewicz J; Płochowski J; Dragan SŁ
Ortop Traumatol Rehabil; 2008; 10(4):350-61. PubMed ID: 18779768
[TBL] [Abstract][Full Text] [Related]
29. [Tensile strength of plate osteosynthesis. Comparative biomechanical study of the original autocompression plate and a functional modification using the ZESPOL principle].
Hopf T; Albert H
Unfallchirurg; 1990 Mar; 93(3):100-4. PubMed ID: 2343317
[TBL] [Abstract][Full Text] [Related]
30. Treatment of periprosthetic tibial plateau fractures in unicompartmental knee arthroplasty: plates versus cannulated screws.
Seeger JB; Jaeger S; Röhner E; Dierkes H; Wassilew G; Clarius M
Arch Orthop Trauma Surg; 2013 Feb; 133(2):253-7. PubMed ID: 23124492
[TBL] [Abstract][Full Text] [Related]
31. A new screw fixation technique for minimally invasive percutaneous plate osteosynthesis.
Güven M; Unay K; Cakici H; Ozturan EK; Ozkan NK
Acta Orthop Belg; 2008 Dec; 74(6):846-50. PubMed ID: 19205334
[TBL] [Abstract][Full Text] [Related]
32. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations.
Estes C; Rhee P; Shrader MW; Csavina K; Jacofsky MC; Jacofsky DJ
J Orthop Trauma; 2008; 22(5):312-6. PubMed ID: 18448984
[TBL] [Abstract][Full Text] [Related]
33. Cortical bone perfusion in plated fractured sheep tibiae.
Kregor PJ; Senft D; Parvin D; Campbell C; Toomey S; Parker C; Gillespy T; Swiontkowski MF
J Orthop Res; 1995 Sep; 13(5):715-24. PubMed ID: 7472750
[TBL] [Abstract][Full Text] [Related]
34. [The effect of an angle-stable plate-screw connection and various screw diameters on the stability of plate osteosynthesis. An FE model study].
Seide K; Zierold W; Wolter D; Kortmann HR
Unfallchirurg; 1990 Dec; 93(12):552-8. PubMed ID: 2281325
[TBL] [Abstract][Full Text] [Related]
35. Functional load of plates in fracture fixation in vivo and its correlate in bone healing.
Stoffel K; Klaue K; Perren SM
Injury; 2000 May; 31 Suppl 2():S-B37-50. PubMed ID: 10853760
[TBL] [Abstract][Full Text] [Related]
36. [Theoretical and clinical bases of the method of osteosynthesis by screws in oblique and spiral fractures of the tibia].
Tkachenko SS; Erokhov AN; Mel'nikov BE
Ortop Travmatol Protez; 1990 Jul; (7):5-9. PubMed ID: 2290680
[TBL] [Abstract][Full Text] [Related]
37. [Influence of stress-relaxation plate on bone geometrics and mechanical property: an experimental study].
Dai K; Dai M; Wang K
Zhonghua Yi Xue Za Zhi; 1995 Jul; 75(7):414-6, 446. PubMed ID: 7553161
[TBL] [Abstract][Full Text] [Related]
38. [Experimental studies on the decrease of tibial fracture load after removal of the osteosynthesis plate].
Jäger M; Dietschi C; Ungethüm M
Hefte Unfallheilkd; 1974; 0(117):34-8. PubMed ID: 4426820
[No Abstract] [Full Text] [Related]
39. Locked vs. unlocked plate osteosynthesis of the proximal humerus - a biomechanical study.
Seide K; Triebe J; Faschingbauer M; Schulz AP; Püschel K; Mehrtens G; Jürgens Ch
Clin Biomech (Bristol, Avon); 2007 Feb; 22(2):176-82. PubMed ID: 17134800
[TBL] [Abstract][Full Text] [Related]
40. Locking plate constructs benefit from interfragmentary lag screw fixation with decreased shear movements and more predictable fracture gap motion in simple fracture patterns.
Märdian S; Schmölz W; Schaser KD; Duda GN; Heyland M
Clin Biomech (Bristol, Avon); 2019 Dec; 70():89-96. PubMed ID: 31445402
[TBL] [Abstract][Full Text] [Related]