These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 28718239)

  • 1. Permanent Pace Maker Implantation Through Axillary Vein Approach.
    Shah B; Hussain C; Awan ZA
    J Ayub Med Coll Abbottabad; 2017; 29(2):241-245. PubMed ID: 28718239
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Axillary vein access for permanent pacemaker and implantable cardioverter defibrillator implantation: Fluoroscopy compared to ultrasound.
    Migliore F; Fais L; Vio R; De Lazzari M; Zorzi A; Bertaglia E; Iliceto S
    Pacing Clin Electrophysiol; 2020 Jun; 43(6):566-572. PubMed ID: 32394452
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Axillary vein technique for pacemaker and implantable defibrillator leads implantation: a safe and alternative approach?
    Migliore F; Curnis A; Bertaglia E
    J Cardiovasc Med (Hagerstown); 2016 Apr; 17(4):309-13. PubMed ID: 25252042
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of lead placement through the subclavian vein technique with fluoroscopy-guided axillary vein technique for permanent pacemaker insertion.
    Sharma G; Senguttuvan NB; Thachil A; Leong D; Naik N; Yadav R; Juneja R; Bahl VK
    Can J Cardiol; 2012; 28(5):542-6. PubMed ID: 22552175
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasound-guided axillary venous access for pediatric and adult congenital lead implantation.
    Clark BC; Janson CM; Nappo L; Pass RH
    Pacing Clin Electrophysiol; 2019 Feb; 42(2):166-170. PubMed ID: 30515865
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Percutaneous axillary vein approach in pediatric pacing: comparison with subclavian vein approach.
    Silvetti MS; Placidi S; Palmieri R; Righi D; Ravà L; Drago F
    Pacing Clin Electrophysiol; 2013 Dec; 36(12):1550-7. PubMed ID: 24164685
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Zero-fluoroscopy permanent pacemaker implantation using Ensite NavX system: Clinical viability or fanciful technique?
    Guo P; Qiu J; Wang Y; Chen G; Proietti R; Fadhle AS; Zhao C; Wen Wang D
    Pacing Clin Electrophysiol; 2018 Feb; 41(2):122-127. PubMed ID: 29222861
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasound-guided venipuncture for implantation of cardiac implantable electronic devices: A single-center, retrospective study.
    Deluca G; Massari VFM; Musaico F; Rosa I; Modugno G; Scardigno AD; Valente L; Leo PD; Ceravolo G; Pittiruti M
    Pacing Clin Electrophysiol; 2020 Jul; 43(7):713-719. PubMed ID: 32452043
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads.
    Migliore F; Siciliano M; De Lazzari M; Ferretto S; Valle CD; Zorzi A; Corrado D; Iliceto S; Bertaglia E
    J Interv Card Electrophysiol; 2015 Sep; 43(3):263-7. PubMed ID: 25956478
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prospective study to develop surface landmarks for blind axillary vein puncture for permanent pacemaker and defibrillator lead implantation and compare it to available contrast venography guided technique.
    Mehrotra S; Rohit MK
    Indian Heart J; 2015; 67(2):136-40. PubMed ID: 26071292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Axillary vein puncture without contrast venography for pacemaker and defibrillator leads implantation.
    Antonelli D; Feldman A; Freedberg NA; Turgeman Y
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1107-10. PubMed ID: 23713786
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved 'cut-down' technique for transvenous pacemaker lead implantation.
    Kolettis TM; Lysitsas DN; Apostolidis D; Baltogiannis GG; Sourla E; Michalis LK
    Europace; 2010 Sep; 12(9):1282-5. PubMed ID: 20519193
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimized Axillary Vein Technique versus Subclavian Vein Technique in Cardiovascular Implantable Electronic Device Implantation: A Randomized Controlled Study.
    Liu P; Zhou YF; Yang P; Gao YS; Zhao GR; Ren SY; Li XL
    Chin Med J (Engl); 2016 Nov; 129(22):2647-2651. PubMed ID: 27823994
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fluoroscopy-guided axillary vein access vs cephalic vein access in pacemaker and defibrillator implantation: Randomized clinical trial of efficacy and safety.
    Jiménez-Díaz J; Higuera-Sobrino F; Piqueras-Flores J; Pérez-Díaz P; González-Marín MA
    J Cardiovasc Electrophysiol; 2019 Sep; 30(9):1588-1593. PubMed ID: 31310038
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of safety and efficacy of pacemaker and defibrillator implantation by axillary incision in pediatric patients.
    Lee JC; Shannon K; Boyle NG; Klitzner TS; Bersohn MM
    Pacing Clin Electrophysiol; 2004 Mar; 27(3):304-7. PubMed ID: 15009854
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Innovation in Permanent Pacemaker's Implantation Technique: Trans-Axillary Approach.
    Shah B; Amir Niaz M; Saidullah S; Zaman F; Mumtaz H; Ghazanfar A
    Cureus; 2021 Apr; 13(4):e14436. PubMed ID: 33996301
    [TBL] [Abstract][Full Text] [Related]  

  • 17. TEMPORARY PACE MAKERS IMPLANTATION: DO WE NEED FLUOROSCOPY?
    Shah B; Awan ZA
    J Ayub Med Coll Abbottabad; 2015; 27(2):284-6. PubMed ID: 26411098
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simple method of axillary venipuncture using single landmark for pacemaker leads implantation.
    Zhao P; Wang Y; Zeng S
    Acta Cardiol; 2023 Aug; 78(6):699-702. PubMed ID: 36222580
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wireless Ultrasound-Guided Axillary Vein Cannulation for the Implantation of Cardiovascular Implantable Electric Devices.
    Franco E; Rodriguez Muñoz D; Matía R; Hernandez-Madrid A; Carbonell San Román A; Sánchez I; Zamorano J; Moreno J
    J Cardiovasc Electrophysiol; 2016 Apr; 27(4):482-7. PubMed ID: 26749504
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transfemoral access when superior venous approach is not feasible equals overall success of permanent pacemaker implantation. Ten-year series.
    García Guerrero JJ; Fernández de la Concha Castañeda J; Doblado Calatrava M; Redondo Méndez Á; Lázaro Medrano M; Merchán Herrera A
    Pacing Clin Electrophysiol; 2017 Jun; 40(6):638-643. PubMed ID: 28349586
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.