124 related articles for article (PubMed ID: 28721299)
1. Development of ionophore-based nanosphere emulsion incorporating ion-exchanger for complexometric titration of thiocyanate anion.
Abdel-Haleem FM; Rizk MS
J Adv Res; 2017 Jul; 8(4):449-454. PubMed ID: 28721299
[TBL] [Abstract][Full Text] [Related]
2. Highly selective thiocyanate optochemical sensor based on manganese(III)-salophen ionophore.
Abdel-Haleem FM; Rizk MS
Mater Sci Eng C Mater Biol Appl; 2017 Jun; 75():682-687. PubMed ID: 28415515
[TBL] [Abstract][Full Text] [Related]
3. Ionophore-based ion-exchange emulsions as novel class of complexometric titration reagents.
Zhai J; Xie X; Bakker E
Chem Commun (Camb); 2014 Oct; 50(84):12659-61. PubMed ID: 25205536
[TBL] [Abstract][Full Text] [Related]
4. Synthesis and characterization of bis nitrato[4-hydroxyacetophenonesemicarbazone) nickel(II) complex as ionophore for thiocyanate-selective electrode.
Chandra S; Hooda S; Tomar PK; Malik A; Kumar A; Malik S; Gautam S
Mater Sci Eng C Mater Biol Appl; 2016 May; 62():18-27. PubMed ID: 26952393
[TBL] [Abstract][Full Text] [Related]
5. Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva.
Urbanowicz M; Sadowska K; Pijanowska D; Pomećko R; Bocheńska M
Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32429165
[TBL] [Abstract][Full Text] [Related]
6. Solvatochromic Dyes as pH-Independent Indicators for Ionophore Nanosphere-Based Complexometric Titrations.
Zhai J; Xie X; Bakker E
Anal Chem; 2015 Dec; 87(24):12318-23. PubMed ID: 26595520
[TBL] [Abstract][Full Text] [Related]
7. Fluorinated tripodal receptors for potentiometric chloride detection in biological fluids.
Pankratova N; Cuartero M; Jowett LA; Howe ENW; Gale PA; Bakker E; Crespo GA
Biosens Bioelectron; 2018 Jan; 99():70-76. PubMed ID: 28738230
[TBL] [Abstract][Full Text] [Related]
8. The first use of a Rh(III) complex as a novel ionophore for thiocyanate-selective polymeric membrane electrodes.
Shamsipur M; Ershad S; Samadi N; Rezvani AR; Haddadzadeh H
Talanta; 2005 Feb; 65(4):991-7. PubMed ID: 18969900
[TBL] [Abstract][Full Text] [Related]
9. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples.
Gupta VK; Singh AK; Gupta B
Anal Bioanal Chem; 2008 Apr; 390(8):2171-81. PubMed ID: 18335212
[TBL] [Abstract][Full Text] [Related]
10. Fluoride-selective polymeric membrane electrodes based on Zr(IV)- and Al(III)-salen ionophores of various structures.
Górski Ł; Matusevich A; Parzuchowski P; Łuciuk I; Malinowska E
Anal Chim Acta; 2010 Apr; 665(1):39-46. PubMed ID: 20381688
[TBL] [Abstract][Full Text] [Related]
11. Ion-selective optode nanospheres as heterogeneous indicator reagents in complexometric titrations.
Zhai J; Xie X; Bakker E
Anal Chem; 2015 Mar; 87(5):2827-31. PubMed ID: 25622089
[TBL] [Abstract][Full Text] [Related]
12. Thiocyanate-selective electrode based on unsymmetrical benzoN(4) nickel(II) macrocyclic complexes.
Abbaspour A; Kamyabi MA; Esmaeilbeig AR; Kia R
Talanta; 2002 Jul; 57(5):859-67. PubMed ID: 18968689
[TBL] [Abstract][Full Text] [Related]
13. From Molecular and Emulsified Ion Sensors to Membrane Electrodes: Molecular and Mechanistic Sensor Design.
Zdrachek E; Bakker E
Acc Chem Res; 2019 May; 52(5):1400-1408. PubMed ID: 31017760
[TBL] [Abstract][Full Text] [Related]
14. Thiocyanate ion-selective PVC membrane electrode based on N,N'-ethylene-bis(4-methylsalicylidineiminato)nickel(II).
Mazloum Ardakani M; Jamshidpour M; Naeimi H; Moradi L
Anal Sci; 2006 Sep; 22(9):1221-6. PubMed ID: 16966813
[TBL] [Abstract][Full Text] [Related]
15. Highly selective thiocyanate membrane electrode based on butane-2,3-dione bis(salicylhydrazonato)zinc(II) complex.
Ardakani MM; Sadeghi A; Salavati-Niasari M
Talanta; 2005 May; 66(4):837-43. PubMed ID: 18970061
[TBL] [Abstract][Full Text] [Related]
16. Calibration-free ionophore-based ion-selective electrodes with a Co(II)/Co(III) redox couple-based solid contact.
Zou XU; Zhen XV; Cheong JH; Bühlmann P
Anal Chem; 2014 Sep; 86(17):8687-92. PubMed ID: 25117517
[TBL] [Abstract][Full Text] [Related]
17. Novel potentiometric application for the determination of pantoprazole sodium and itopride hydrochloride in their pure and combined dosage form.
Ragab MT; Abd El-Rahman MK; Ramadan NK; El-Ragehy NA; El-Zeany BA
Talanta; 2015 Jun; 138():28-35. PubMed ID: 25863367
[TBL] [Abstract][Full Text] [Related]
18. Anion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity.
Bakker E; Malinowska E; Schiller RD; Meyerhoff ME
Talanta; 1994 Jun; 41(6):881-90. PubMed ID: 18966013
[TBL] [Abstract][Full Text] [Related]
19. Lead ion-selective electrodes based on polyphenylenediamine as unique solid ionophores.
Huang MR; Rao XW; Li XG; Ding YB
Talanta; 2011 Sep; 85(3):1575-84. PubMed ID: 21807224
[TBL] [Abstract][Full Text] [Related]
20. Solid-contact Hg(II)-selective electrode based on a carbon-epoxy composite containing a new dithiophosphate-based ionophore.
Juarez-Gomez J; Perez-Garcia F; Ramirez-Silva MT; Rojas-Hernandez A; Galan-Vidal CA; Paez-Hernandez ME
Talanta; 2013 Sep; 114():235-42. PubMed ID: 23953465
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]