These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
193 related articles for article (PubMed ID: 28727209)
1. A dual flip angle 3D bSSFP magnetization transfer-like method to differentiate between recent and old myocardial infarction. Germain P; El Ghannudi S; Labani A; Jeung MY; Gangi A; Ohlmann P; Roy C J Magn Reson Imaging; 2018 Mar; 47(3):798-808. PubMed ID: 28727209 [TBL] [Abstract][Full Text] [Related]
2. Non-contrast myocardial infarct scar assessment using a hybrid native T Duan C; Zhu Y; Jang J; Rodriguez J; Neisius U; Fahmy AS; Nezafat R Magn Reson Med; 2019 May; 81(5):3192-3201. PubMed ID: 30565296 [TBL] [Abstract][Full Text] [Related]
3. Comparison of fast multi-slice and standard segmented techniques for detection of late gadolinium enhancement in ischemic and non-ischemic cardiomyopathy - a prospective clinical cardiovascular magnetic resonance trial. Muehlberg F; Arnhold K; Fritschi S; Funk S; Prothmann M; Kermer J; Zange L; von Knobelsdorff-Brenkenhoff F; Schulz-Menger J J Cardiovasc Magn Reson; 2018 Feb; 20(1):13. PubMed ID: 29458430 [TBL] [Abstract][Full Text] [Related]
4. Native T Liu X; Hou JL; Yang ZG; Xia CC; Xie LJ; Ye PF; Peng WL; Li L; Yang MX; Guo YK J Magn Reson Imaging; 2018 May; 47(5):1406-1414. PubMed ID: 29044903 [TBL] [Abstract][Full Text] [Related]
5. Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession. Stromp TA; Leung SW; Andres KN; Jing L; Fornwalt BK; Charnigo RJ; Sorrell VL; Vandsburger MH J Cardiovasc Magn Reson; 2015 Oct; 17():90. PubMed ID: 26520782 [TBL] [Abstract][Full Text] [Related]
6. Feasibility study of a single breath-hold, 3D mDIXON pulse sequence for late gadolinium enhancement imaging of ischemic scar. Foley JRJ; Fent GJ; Garg P; Broadbent DA; Dobson LE; Chew PG; Brown LAE; Swoboda PP; Plein S; Higgins DM; Greenwood JP J Magn Reson Imaging; 2019 May; 49(5):1437-1445. PubMed ID: 30597661 [TBL] [Abstract][Full Text] [Related]
7. REPAIRit: Improving Myocardial Nulling and Ghosting Artifacts of 3D Navigator-Gated Late Gadolinium Enhancement Imaging During Arrhythmia. Hu C; Huber S; Latif SR; Santacana-Laffitte G; Mojibian HR; Baldassarre LA; Peters DC J Magn Reson Imaging; 2019 Mar; 49(3):688-699. PubMed ID: 30252987 [TBL] [Abstract][Full Text] [Related]
8. Clinical performance of high-resolution late gadolinium enhancement imaging with compressed sensing. Basha TA; Akçakaya M; Liew C; Tsao CW; Delling FN; Addae G; Ngo L; Manning WJ; Nezafat R J Magn Reson Imaging; 2017 Dec; 46(6):1829-1838. PubMed ID: 28301075 [TBL] [Abstract][Full Text] [Related]
9. T(Rho) and magnetization transfer and INvErsion recovery (TRAMINER)-prepared imaging: A novel contrast-enhanced flow-independent dark-blood technique for the evaluation of myocardial late gadolinium enhancement in patients with myocardial infarction. Muscogiuri G; Rehwald WG; Schoepf UJ; Suranyi P; Litwin SE; De Cecco CN; Wichmann JL; Mangold S; Caruso D; Fuller SR; Bayer Nd RR; Varga-Szemes A J Magn Reson Imaging; 2017 May; 45(5):1429-1437. PubMed ID: 27690324 [TBL] [Abstract][Full Text] [Related]
10. Assessment of magnetization transfer effects in myocardial tissue using balanced steady-state free precession (bSSFP) cine MRI. Weber OM; Speier P; Scheffler K; Bieri O Magn Reson Med; 2009 Sep; 62(3):699-705. PubMed ID: 19572387 [TBL] [Abstract][Full Text] [Related]
11. Clinical evaluation of two dark blood methods of late gadolinium quantification of ischemic scar. Foley JRJ; Broadbent DA; Fent GJ; Garg P; Brown LAE; Chew PG; Dobson LE; Swoboda PP; Plein S; Higgins DM; Greenwood JP J Magn Reson Imaging; 2019 Jul; 50(1):146-152. PubMed ID: 30604492 [TBL] [Abstract][Full Text] [Related]
12. Myocardial infarct sizing by late gadolinium-enhanced MRI: Comparison of manual, full-width at half-maximum, and n-standard deviation methods. Zhang L; Huttin O; Marie PY; Felblinger J; Beaumont M; Chillou C; Girerd N; Mandry D J Magn Reson Imaging; 2016 Nov; 44(5):1206-1217. PubMed ID: 27096741 [TBL] [Abstract][Full Text] [Related]
13. Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach. Rutz T; Piccini D; Coppo S; Chaptinel J; Ginami G; Vincenti G; Stuber M; Schwitter J Int J Cardiovasc Imaging; 2016 Dec; 32(12):1735-1744. PubMed ID: 27549804 [TBL] [Abstract][Full Text] [Related]
14. Improved dark blood late gadolinium enhancement (DB-LGE) imaging using an optimized joint inversion preparation and T Basha TA; Tang MC; Tsao C; Tschabrunn CM; Anter E; Manning WJ; Nezafat R Magn Reson Med; 2018 Jan; 79(1):351-360. PubMed ID: 28382726 [TBL] [Abstract][Full Text] [Related]
15. Diagnostic accuracy of late iodine-enhancement dual-energy computed tomography for the detection of chronic myocardial infarction compared with late gadolinium-enhancement 3-T magnetic resonance imaging. Wichmann JL; Bauer RW; Doss M; Stock W; Lehnert T; Bodelle B; Frellesen C; Vogl TJ; Kerl JM Invest Radiol; 2013 Dec; 48(12):851-6. PubMed ID: 23907104 [TBL] [Abstract][Full Text] [Related]
16. Clinical evaluation of three-dimensional late enhancement MRI. Bratis K; Henningsson M; Grigoratos C; Omodarme MD; Chasapides K; Botnar R; Nagel E J Magn Reson Imaging; 2017 Jun; 45(6):1675-1683. PubMed ID: 27801994 [TBL] [Abstract][Full Text] [Related]
17. Effect of inversion time on the precision of myocardial late gadolinium enhancement quantification evaluated with synthetic inversion recovery MR imaging. Varga-Szemes A; van der Geest RJ; Schoepf UJ; Spottiswoode BS; De Cecco CN; Muscogiuri G; Wichmann JL; Mangold S; Fuller SR; Maurovich-Horvat P; Merkely B; Litwin SE; Vliegenthart R; Suranyi P Eur Radiol; 2017 Aug; 27(8):3235-3243. PubMed ID: 28050692 [TBL] [Abstract][Full Text] [Related]
18. Three-dimensional segmentation of the left ventricle in late gadolinium enhanced MR images of chronic infarction combining long- and short-axis information. Wei D; Sun Y; Ong SH; Chai P; Teo LL; Low AF Med Image Anal; 2013 Aug; 17(6):685-97. PubMed ID: 23562069 [TBL] [Abstract][Full Text] [Related]
19. Convolutional neural network-based approach for segmentation of left ventricle myocardial scar from 3D late gadolinium enhancement MR images. Zabihollahy F; White JA; Ukwatta E Med Phys; 2019 Apr; 46(4):1740-1751. PubMed ID: 30734937 [TBL] [Abstract][Full Text] [Related]
20. Volumetric late gadolinium-enhanced myocardial imaging with retrospective inversion time selection. Kecskemeti S; Johnson K; François CJ; Schiebler ML; Unal O J Magn Reson Imaging; 2013 Nov; 38(5):1276-82. PubMed ID: 23389851 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]